Search PubMed⌕ Search

Biomedical subjects

D C MacGregor

Publications and source records attributed to D C MacGregor.

56 records · Page 4Linked to original sources

A compliant Corethane/Dacron composite vascular prosthesis. Comparison with 4-mm ePTFE grafts in a canine model.

We have developed a composite vascular prosthesis with the inner blood interfacing layer made of a porous elastomeric membrane of spun Corethane fibers (10-15 microns in diameter, pore size 30-60 microns) impregnated with a gelatin-heparin complex and an outer soft tissue interfacing warp knitted Dacron sheath. Forty-eight Corethane/Dacron composite (CDC) vascular grafts, 4 mm in diameter and 5 cm in length, and 48 expanded polytetrafluoroethylene (ePTFE) vascular grafts of similar size were implanted bilaterally as end to end interposition grafts on opposite sides in the carotid and femoral arteries in dogs on low dose (162 mg/day) aspirin. Patency at 3 months was 37/48 (77%) for the ePTFE grafts and 44/48 (91.7%) for the CDC grafts. Fisher's exact test (two-tailed comparison) indicates the probability of superior CDC graft patency to be 95.5%. In the seven pairs of grafts in which one graft was occluded and the contralateral graft of another type was patent, the CDC graft was patent and the ePTFE graft was occluded in every instance. Explant histology and scanning electron microscopy showed greater collagenization, less residual platelet-fibrin and red blood cell deposits, and more frequent mid-graft endothelialization in the CDC grafts than in the ePTFE grafts.

Animals↗

A Corethane/polyester composite vascular prosthesis for vascular access. Comparison with expanded polytetrafluoroethylene grafts in a canine model.

An important need in hemodialysis is a self-sealing prosthesis for vascular access with at least equivalent patency and biostability to expanded polytetrafluoroethylene (ePTFE) alternatives. The authors have developed a Corethane/polyester composite (CPC) graft with an inner blood interfacing layer of spun Corethane fibers (10-15 microns diameter; pore size 30-60 microns) impregnated with a gelatin-heparin complex and an outer soft tissue interfacing warp-knitted polyester sheath. Twenty-six CPC grafts (6 mm internal diameter; 25-30 cm length) and eight Gore-Tex ePTFE grafts (same dimensions) were implanted as femoral artery-to-vein shunts in dogs on low dose (162 mg/day) aspirin, and subjected to weekly dialysis needle punctures for up to 52 weeks. Patency was 73% (19/26 with 15 at 52 weeks) for the CPC grafts and 63% (5/8 at 52 weeks) for the ePTFE controls, with more favorable healing (e.g., less extensive mural thrombi) of the CPC grafts. The hemostasis time per needle pair after removal (3.1 min mean for CPC versus 21.2 min mean for ePTFE) and the blood loss in achieving hemostasis (5.7 g mean for CPC versus 47.9 g for ePTFE) documented the significant (p < 0.0001) performance advantages of the CPC prosthesis.

Animals↗