Search PubMedSearch

Biomedical subjects

D C Bloomgarden

Publications and source records attributed to D C Bloomgarden.

6 recordsLinked to original sources

Right ventricular regional function using MR tagging: normals versus chronic pulmonary hypertension.

Right ventricular (RV) regional function, in both normal and diseased states, is not well characterized. Using 1D MR myocardial tagging, RV and septal intramyocardial segmental shortening was noninvasively measured in ten healthy subjects and in seven patients with chronic pulmonary hypertension. The normal RV free wall regional shortening was not uniform. A pattern of increasing RV free wall short-axis shortening was found from the RV outflow tract to the RV apex, and a more complex pattern of RV free wall long-axis shortening was observed. Both regional short- and long-axis shortening were globally reduced in pulmonary hypertension patients, with the greatest decreases in the RV outflow tract and in the basal septal wall region. Regional RV function can be quantitatively evaluated using MR tagging to determine the impact of chronic pulmonary hypertension on RV performance.

Adolescent

Integrated MRI assessment of regional function and perfusion in canine myocardial infarction.

A single integrated examination using regional measurements of perfusion from contrast-enhanced MRI and three-dimensional (3D) strain from tissue-tagged MRI was developed to differentiate infarcted myocardium from adjacent tissue with functional abnormalities. Ten dogs were studied at baseline and 10 days after a 2-hour occlusion of the left anterior descending coronary artery (LAD). Strain was determined using a 3D finite element model. Two-dimensional measurements of hypoenhancing regions were highly correlated with myocardial viability (r = 0.96). Signal intensity versus time curves obtained from contrast-enhanced MRI were used for quantitative perfusion analysis. The remote and adjacent noninfarcted tissue of the dogs with LAD occlusion, as well as the infarcted tissue, exhibited abnormal deformation patterns as compared to normal dogs (positive predictive value (PPV) of strain determination of infarction = 66%). Integration of contrast-enhanced MRI results with 3D strain analysis enabled the delineation of the myocardial infarction (PPV = 100%) from functionally compromised myocardium. This integrated cardiac examination shows promise for noninvasive serial assessment of potentially jeopardized noninfarcted myocardium to study the process of infarct remodeling and expansion.

Animals

Global cardiac function using fast breath-hold MRI: validation of new acquisition and analysis techniques.

Calculation of global cardiac function parameters has been validated using fast, segmented k-space, breath-hold, gradient-echo, magnetic resonance images. Images of phantoms, experimental animals, normal volunteers, and patients were acquired with a 1.5 T clinical scanner. Humans were imaged using two phased-array surface coils in multicoil mode. Myocardial contours were extracted using a new interactive, semi-automated method based on the active contour model method. Images were acquired in the short-axis orientation, and, using a new imaging and analysis strategy, in rotating plane long-axis orientations, to provide better definition of the valve planes and the apex, and also to reduce the number of slices (compared with the short-axis method) required to sample the whole heart. Validation was accomplished through calculation of the volumes of phantoms and left and right ventricular masses of animal hearts. Functional parameters from MRI were compared with those from echocardiograms and radionuclide angiograms in normal volunteers and patients, respectively.

Adult

Right and left ventricular volume and ejection fraction by tomographic gated blood-pool scintigraphy.

UNLABELLED: Tomographic techniques separate overlying structures, permitting measurements of absolute ventricular volumes. The purpose of this study was to determine absolute right and left ventricular volume and ejection fraction measurements with tomographic gated equilibrium blood-pool scintigraphy (TMUGA) compared to MRI and conventional planar scintigraphy. METHODS: Eighteen patients were studied. Ventricular volumes for TMUGA and MRI were calculated by modified Simpson's rule. TMUGA regions were defined by constraints including phase analysis, intensity threshold and visual inspection. MRI studies were acquired with a fast gradient-echo, ECG-gated, breath-hold technique and boundaries were defined by a semiautomated contour method. Conventional gated first-pass radionuclide angiography (FP) and planar gated equilibrium blood-pool scintigraphy (PMUGA) were performed for RV EF and LV EF, respectively. RESULTS: TMUGA absolute right ventricular volumes showed excellent-correlation with MRI for both right ventricular volumes (r = 0.91, slope = 0.90, s.e.e. = 15.7) and left ventricular volumes (r = 0.96, slope = 0.88, s.e.e. = 18.2). For left ventricular ejection fraction, TMUGA also showed excellent correlation with MRI (r = 0.94, slope = 1.10, s.e.e. = 9.0) and planar MUGA (r = 0.97, slope = 1.23, s.e.e. = 6.2). For right ventricular ejection fraction, TMUGA showed good correlation with both MRI (r = 0.88, slope = 0.79, s.e.e. = 6.0) and first-pass planar scintigraphy (r = 0.86, slope = 1.2, s.e.e. = 7.9). CONCLUSION: Tomographic gated blood-pool scintigraphy absolute right and left ventricular volumes and ejection fractions show good correlation with accepted techniques. Further studies are necessary to define the reproducibility of this method.

Cardiac Volume

A versatile and sensitive method for measuring oxygen.

Oxygen dependence of the lifetime of the excited triplet state of phosphorescent molecules can be used to measure the oxygen concentration in aqueous media. These measurements are insensitive to much of the optical interference that limits the usefulness of measurements based on the oxygen dependent quenching of luminescence intensity. The measurements also extend to significantly lower oxygen concentrations than are normally attainable using oxygen electrodes. The phosphorescence lifetimes can be accurately measured from a few microseconds to seconds, permitting a wide dynamic range of oxygen concentration measurements. With currently available probes, for example, it is possible to make continuous measurement of oxygen concentrations from 10(-4) M to 10(-8) M in a single experiment.

Animals