Strengths and limitations of the minimum evolution principle.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to D Bryant.
Explore the source record for details and available documents.
How quality of center-based child care relates to early cognitive and language development was examined longitudinally from 6 to 36 months of age in a sample of 89 African American children. Both structural and process measures of quality of child care were collected through observation of the infant classroom. Results indicated that higher quality child care was related to higher measures of cognitive development (Bayley Scales of Infant Development), language development (Sequenced Inventory of Communication Development), and communication skills (Communication and Symbolic Behavior Scales) across time, even after adjusting for selected child and family characteristics. In addition, classrooms that met professional recommendations regarding child:adult ratios tended to have children with better language skills. Classrooms that met recommendations regarding teacher education tended to have girls with better cognitive and receptive language skills. These findings, in conjunction with the growing child-care literature, provide further evidence that researchers and policymakers should strive to improve the quality of child care to enhance early development of such vulnerable children.
DIASURV is a computerized surveillance program developed to monitor the interaction of a large cohort of diabetic patients with a tertiary care institution. The input of this simple program consists of a file of diabetic patients, the daily census of hospital inpatients, and the daily census of hospital outpatients. Written in COBOL, the program consists of edit and file-maintenance components and inpatient and outpatient search components. The output is a daily listing of all inpatient (x- = 60) and outpatient transactions (x- = 20) for the cohort of 1,800 patients. The output also summarizes previous exposures of patients to specific bedside and classroom activities in diabetes education. DIASURV has a variety of applications in terms of organization of teaching efforts and facilitated access to a limited amount of patient management information.
BACKGROUND: To determine the influence of HLA mismatching on rejection after cardiothoracic organ transplantation, we analyzed results in 243 recipients. METHODS: There were 183 heart, 25 heart-lung, and 35 single lung recipients, all receiving triple-drug immunosuppression with anti-thymocyte globulin induction. Zero, one, and two mismatches occurred by chance at each locus in between 0% to 9%, 26% to 35%, and 47% to 70% of recipients, respectively. RESULTS: In heart recipients, compared with a two mismatch, a zero mismatch was associated with a lower linearized rejection rate in the first 6 months. A zero B locus mismatch was likewise associated with less rejection in month 1, and DR zero mismatch with reduced rejection in the first 3 months. Steroid withdrawal was more successful in those with zero mismatch at any locus. In heart-lung recipients linearized rejection was significantly lower in those with lesser degrees of A and DR locus mismatching, and after single-lung transplantation linearized rejection was significantly lower with lesser degrees of A and B locus mismatching from 3 to 6 months only. Actuarial survival did not differ for any organ with any degree of mismatch at any locus. CONCLUSIONS: HLA mismatching affects rejection, but the effect is limited to the early postoperative period for heart and heart-lung recipients. Lower grades of mismatch increase the likelihood of successful steroid withdrawal for heart recipients. The chance occurrence of no mismatch at any locus is rare, making prospective matching infeasible. HLA mismatching identifies patients at higher risk of rejection. The best use of this information may be to guide early immunosuppression, limiting prospective matching to retransplants or with presensitized recipients.
BACKGROUND AND METHODS: We compared outcome measures in twenty single lung transplant recipients: 10 patients received the first lung of a donor pair (group 1), and 10 patients received the second lung (group 2) to determine the feasibility of sequential use, respectively, of donor lungs from the same donor in the same institution. The paired recipients underwent transplantation in the same operating room by the same surgical team. Both groups were well matched for age, gender, pretransplantation symptom class and diagnosis. RESULTS: The ischemic time for group 1 versus group 2 was 164 +/- 53 minutes (mean +/- standard deviation) (range 103 to 250 minutes) versus 377 +/- 53 minutes (range 315 to 445 minutes), respectively, (p < 0.001), but the longer ischemic time for group 2 did not adversely affect time to extubation (10.5 +/- 5.1 hours versus 10.3 +/- 7.6 hours; p = Not significant), early gas exchange (partial pressure of arterial oxygen on a fractional concentration of oxygen in inspired gas of 0.60: 237 +/- 61 versus 267 +/- 88 mm Hg; p = Not significant), length of hospital stay (16 +/- 13 days versus 16 +/- 5 days; p = Not significant), or actuarial one-year survival (80 +/- 12% versus 90 +/- 12%; p = Not significant). However, acute lung rejection (expressed as events/100 days) was more common within the first 3 months in group 1 versus group 2 (2.68 +/- 0.57 versus 1.32 +/- 0.38, respectively; p < 0.01), as were infectious events (2.07 +/- 0.50 versus 0.99 +/- 0.33; p < 0.01). CONCLUSIONS: These data confirm the safety of using the second lung from a donor pair sequentially in the same institution. The longer cold ischemic time for the second lung does not impair demonstrably early graft function and may be associated with a lower perioperative morbidity from acute rejection and subsequent infection. One-year outcome appears favorable for both groups.