Is the GraftConnector a valid alternative to running suture in end-to-side coronary arteries anastomoses?

BACKGROUND: An animal study was carried out to compare long-term patency rates of coronary anastomoses performed with the GraftConnector versus running suture technique. METHODS: 10 sheep, 45 to 55 kg, underwent off-pump coronary artery bypass grafting (right internal mammary artery to left anterior descending artery). In 5 animals, the anastomosis was performed with a GraftConnector and in 5 animals with 7-0 running suture. Intraoperative fluoroscopy and a fluoroscopic control at 6 months were performed. After 6 months, the animals were sacrificed and the anastomoses were examined histologically. RESULTS: All animals survived at 6 months with 100% anastomosis patency rates in both groups. In the GraftConnector group, the anastomosis diameter at 6 months fluoroscopy was 118% of native left anterior descending artery versus 97% of the control group. Luminal anastomotic width at histology was 1.7 +/- 0.2 mm in the device group versus 1.6 +/- 0.1 mm in the control group. Mean intimal hyperplasia thickness was 0.21 +/- 0.1 mm in the device group versus 0.01 mm in the control group. CONCLUSIONS: The GraftConnector provides a consistent and reproducible coronary artery anastomosis and reduces technical demand and manual dexterity in coronary operations. Long-term results demonstrate that off-pump coronary artery bypass grafting performed with the GraftConnector had the same patency rate and luminal width as those performed with running suture.

Anastomosis, Surgical↗

The GraftConnector experience. Long-term patency and histological work up in an animal model.

BACKGROUND: A device to perform sutureless end-to-side coronary artery anastomosis has been developed by means of stent technology (GraftConnector). The present study assesses the long-term quality of the GraftConnector anastomosis in a sheep model. METHODS: In 8 adult sheep, 40-55 kg in weight, through left anterior thoracotomy, the right internal mammary artery (RIMA) was prepared and connected to the left anterior descending artery (LAD) by means of GraftConnector, on beating heart, without using any stabilizer. Ticlopidine 250 mg/day for anticoagulation for 4 weeks and Aspirin 100 mg/day for 6 months were given. The animals were sacrificed after 6 months and histological examination of anastomoses was carried out after slicing with the connector in situ for morphological analysis. RESULTS: All animals survived at 6 months. All anastomoses were patent and mean luminal width at histology was 1.8 +/- 0.2 mm; mean myotomia hyperplasia thickness was 0.21 +/- 0.1 mm. CONCLUSIONS: Long-term results demonstrate that OPCABGs performed with GraftConnector had 100% patency rate. The mean anastomotic luminal width corresponds to mean LAD's adult sheep diameter. We may speculate that myotomia hyperplasia occurred as a result of local device oversizing.

Animals↗

Evaluation of a new device for quick sutureless coronary artery anastomosis in surviving sheep.

OBJECTIVE: A new device for performing quick sutureless vascular anastomosis by means of stent technology has recently been developed by Jomed International, Helsingborg, Sweden. The efficacy of this GraftConnector was studied in a sheep model. METHODS: In adult sheep, a left anterior thoracotomy under the fourth rib extended across the sternum gave good access to the left anterior descending branch (LAD) and the right internal mammary artery (RIMA). On beating hearts, the GraftConnector group had the RIMA connected to the LAD by means of the new device, while the control animals had the same anastomoses sutured with continuous 7-0 polypropylene sutures. The time for completing the anastomosis (ischemic time) was recorded and the blood flow in the RIMA was recorded with the proximal LAD open and closed, respectively. An intra-operative fluoroscopy with contrast injection directly into the graft was done. Finally the proximal LAD was ligated. The surviving animals are to be followed up. RESULTS: Seven (46%) of the 15 animals operated on with the traditional suturing technique and seven (63%) of the 11 GraftConnector sheep survived the procedures and are to be followed up. The 11 anastomoses done with the GraftConnector were completed in 2.41+/-0.2 min, and the 14 anastomoses sutured with continuous suture were completed in 6.93+/-0.419 min (P<0.0001). The RIMA blood-flows in the two groups were comparable and are presented. All the surviving animals had open anastomoses at fluoroscopy. CONCLUSIONS: Quick coronary artery anastomoses without suturing on beating hearts can be completed with the new GraftConnector. The GraftConnector creates reproducible anastomoses in much less time than suturing, the per-operative mortality in the GraftConnector Group was accordingly lower. Long-time follow-up of the patency in surviving animals is pending. The presented device may ultimately permit quick anastomoses endoscopically.

Anastomosis, Surgical↗

[Double recurrence of myxoma of the left atrium. Apropos of a case].

Multiple recurrences of cardiac myxomas are rare and high-light the problem of re-operation. We report a case of double recurrence of left atrial myxoma and analyse the causes of recurrence. In our case, the first myxoma was inserted in the left inter-atrial septum, and the first recurrent tumor was inserted near the pulmonary vein, forming adhesion with the inter-atrial septum. The second recurrent tumor was inserted in the inter-atrial septum. The first operation resected the tumor, including part of the inter-atrial septum, and the sides of the septum were sutured. The two following operations used a patch for the septoplasty. This case is sporadic and not included in the high risk myxoma recurrence syndrome. Incomplete tumor resection is incriminated in one third of recurrences but seems unlikely in our case.

Adult↗