Search PubMed⌕ Search

Biomedical subjects

D Boudart

Publications and source records attributed to D Boudart.

At least 19 recordsLinked to original sources

[Satisfaction survey in general hospital personnel involved in blood transfusion: implementation of the ISO 9001: 2000 standard].

As part of its policy of constant quality improvement, Etablissement Français du Sang (EFS) des Pays de la Loire (Pays de la Loire Regional blood transfusion institution) carried out a satisfaction survey among the hospital personnel involved in prescribing and using immuno-hematological tests and labile blood products. The polling tool selected by agreement between the hospital management and quality assurance department was a questionnaire that permitted item rating and free commentary. It addressed the personnel's perception of the quality of erythrocyte immuno-hematological (EIH) testing and of the products administered, as well as their perception of the quality of communications with the local EFS. The questionnaire was sent to 26 physicians and 32 senior nurses in 15 hospital departments. The reply rate was 60% and expressed a 85% overall satisfaction level. Dissatisfaction causes were more specifically analysed, the main one involving labile blood product distribution in emergency situations. A joint undertaking by the EFS and the hospital led to the implementation of corrective measures, including the writing and implementation of a common standard operating procedure for emergency transfusion management. The results obtained demonstrated the feasibility of this type of survey and the interest, to a blood transfusion centre and the hospital personnel involved in transfusion, of assessing their very own perception of service quality.

Blood Transfusion↗

Satisfaction survey in general hospital personnel involved in blood transfusion: implementation of the ISO 9001: 2000 standard.

As part of its policy of constant quality improvement, Etablissement francais du sang (EFS) des pays de la Loire (Pays de la Loire Regional Blood Transfusion Centre) carried out a satisfaction survey among the hospital personnel involved in prescribing and using immunohaematological tests and labile blood products (LBP). The polling tool selected by agreement between the Saint Nazaire's hospital management and Quality Assurance (QA) Department was a questionnaire that permitted item rating and free commentary. It addressed the personnel's perception of the quality of erythrocyte immunohaematological (EIH) testing and of the products administered, as well as their perception of the quality of communications with the local EFS. The questionnaire was sent to 26 physicians and 32 senior nurses in 15 hospital departments. The reply rate was 60% and expressed an 85% overall satisfaction level. Dissatisfaction causes were more specifically analysed, the main one involving LBP distribution in emergency situations. A joint undertaking by the EFS and the hospital led to the implementation of corrective measures, including the writing and implementation of a common standard operating procedure for emergency transfusion management. The results obtained demonstrated the feasibility of this type of survey and the interest, to a blood transfusion centre and the hospital personnel involved in transfusion, of assessing their very own perception of service quality.

Blood Transfusion↗

[Analytical study of the Abbott and Ortho tests for screening and confirmation of anti-HCV antibodies. Le groupe de Travail "Hépatites virales" de la Société Française de Transfusion Sanguine].

Anti-HCV systematic screening on blood donation was mandatory in France since first of March 1991. Two laboratories (Ortho-Chiron and Abbott) have introduced in Europe successively two kinds of hepatitis C positive diagnosis with 1st and 2nd generation ELISA screening and confirmatory assays. The aim of this multicentric study was to evaluated the sensibility and specificity of these tests. For that, they used 10,090 blood sera. As a result we have seen that the new "second generation" screening assays have a higher sensitivity without less of specificity for the confirmatory tests.

Antigens, Viral↗

[Hepatitis C virus and transfusion: policy regarding the donation and the donor. Groupe "Hépatites Virales" de la Société Nationale de Transfusion Sanguine].

Hepatitis C virus (HCV) discovery and introduction of anti-HCV antibodies screening in blood transfusion imply the necessity of a good blood donations and blood donors policy. Detection of a seropositivity during the screening must be completed with a confirmatory test. The results are directly used to inform donors and define the blood products policy. Donors with positive results on confirmatory test are discarded and have physical and biological examinations in hepatology. Individuals with indeterminate or negative results must be retested for the HCV serology. Furthermore, because of a rapid improvement in the fields of technology, diagnosis and therapy of HCV, an adaptation of the policy is necessary.

Blood Donors↗

Fibronectin in HIV-infected patients: a prospective study.

Fibronectin, a non-specific opsonin involved in the clearance of microorganisms, is thought to play a role in various infectious disease processes. Its diagnostic value as a biological marker of infection and/or prognosis in human immunodeficiency virus (HIV) patients is questionable. We conducted a prospective study to evaluate plasma fibronectin levels in patients with HIV infection at different stages of the disease. Eighty-one consecutive HIV-infected patients seen in our department were evaluated clinically and biologically. Classifications according to the Centers for Disease Control (CDC) stages were: Group II (n = 22), Group III (n = 17), acquired immunodeficiency syndrome (AIDS) (n = 17) and AIDS related complex (n = 25). Plasma fibronectin levels were measured by a radial immunodiffusion assay. Plasma fibronectin levels were not different between HIV-infected patients (344 +/- 128 mg/L) and controls (n = 20, 335 +/- 45 mg/L). Among the 81 patients, plasma fibronectin levels were within normal value in 79%, with no significant difference of mean plasma fibronectin between the different CDC groups. No correlation was found between plasma fibronectin and other biological parameters including CD4+ cells, p24 antigen, beta-2-microglobulin. Furthermore, no correlation was noted between fibronectin and complement levels or presence of circulating immune complexes. These results suggest that plasma fibronectin is not a useful marker in patients with HIV infection.

AIDS-Related Complex↗

[Practical approach to the discovery of serum markers for infection by hepatitis B virus (HBs antigen or anti HBc antibody). Hypertransaminasemia or the two anomalies in a blood donor].

By now in France HBV seric markers (Ag HBs and Ac HBc) and transaminases level (ALT) screenings are compulsory by law in blood donors. People whose blood donation is discarded should be informed. A clinical, epidemiological and virological survey of such donors is required to differentiate healthy Ag HBs carriers and patients suffering from hepatitis B (who may eventually be treated). Similar guidelines may be recommended for the blood donors presenting high transaminases level without HBV seric markers in order to find a cause for such impaired biochemical tests: overweight, alcohol, drug consumption, auto-immune liver disease, genetic disorder, Non-A, Non-B, Non-C hepatitis....

Alanine Transaminase↗

High-fold expansion of human cytotoxic T-lymphocytes specific for autologous melanoma cells for use in immunotherapy.

We set up a culture protocol that consistently allows high-fold expansion of tumor-specific T-lymphocytes from most melanoma-invaded biopsies with low doses of recombinant interleukin-2 (rIL-2). Between 2-60 x 10(6) T-lymphocytes could be obtained and cryopreserved from 12 out of 13 patients, by culturing only 50 mm3 tumor tissue with rIL-2. Thawed lymphocytes from 11 of these patients could then be expanded by a median factor of 32,800 by culturing them successively in microplates on irradiated feeder cells with rIL-2 for approximately 2 weeks and then in culture bags or flasks with only rIL-2 for 1-2 additional weeks. Dead feeder cells disappeared during the last phase of the lymphocyte culture with rIL-2. Interestingly, each time they were expanded under these conditions, tumor-infiltrating lymphocytes (TIL) or lymph-node lymphocytes developed a lytic activity apparently restricted to the autologous melanoma line. Tumor-specific lysis, which was maximum at around the end of T-lymphocyte expansion, ranged between 31-63% lysis at an effector:target (E:T) ratio of 20:1. This culture method would thus appear to be suitable for reliable production of over 10(10) T-lymphocytes with good tumor-specific lytic activity from most melanoma-invaded biopsy. It should permit analysis of the immunotherapeutic potential of these populations reinjected into cancer patients.

Cell Division↗

[Clinical hemorheologic study of 65 inflammatory syndromes explored using standard biologic examination and total blood filtration test].

The hemorrheologic impact of an inflammatory syndrome was investigated in a prospective biological study of 65 patients by using an erythrocyte filtration test on total blood. Impact was assessed by a statistical study of correlations between relative filtration time (RFT), inflammation-reactive proteins (IRP) and the different parameters of the hemogram. A stepwise multiple regression test (SMRT) indicated the dominant role of fibrinogen in determining acceleration of the sedimentation rate (p less than 10(-3) and lengthening of RFT (p less than 10(-3). Moreover, RFT appeared to be very significantly correlated with polymorphonuclears (R = 0.55; p less than 10(-3] hematocrit as measured by the centrifugation technique (R = 0.34; p = 0.005) and corpuscular concentration in hemoglobin (CCHM) (R = 0.30; p = 0.01). A chart predictive of microcirculatory risk was deduced from the study based on fibrinogen values and hematocrit. However, the relatively low rate of reduction in the total variance observed during SMRT suggests the quite relative role of the studied parameters in erythrocyte filtration disturbances during an inflammatory syndrome.

Blood Sedimentation↗