Search PubMed⌕ Search

Biomedical subjects

D Barnett

Publications and source records attributed to D Barnett.

At least 37 records · Page 2Linked to original sources

Perceived social support mediates between prior attachment and subsequent adjustment: a study of urban African American children.

The processes whereby attachment and other social and cognitive factors contribute to social and emotional adjustment were examined. Participants were 56 African American children from low-income urban families. Attachment and sociability were assessed in the strange situation when children were 4.5 years old. Two years later, children were interviewed regarding their perceptions of social support and their attributions about others' intentions. Also assessed at Time 2 were child verbal intelligence, defensive response style, children's self-reports, and parent reports of child adjustment. As expected, attachment uniquely predicted perceived social support. Insecure attachment predicted self-reports of behavior problems and parental report of internalizing problems. Perceived social support was associated positively and significantly with viewing ambiguously depicted actions as prosocial rather than aggressive. Perceived social support was found to mediate the relation between attachment and adjustment. Results suggest that behaviorally mediated strategies for relating to caregivers in early childhood predict generalized social perception, thought, and emotion at later ages.

Black or African American↗

Absolute CD4+ T-lymphocyte and CD34+ stem cell counts by single-platform flow cytometry: the way forward.

To determine the potential advantage of single-platform technology in the enumeration of CD4+ T lymphocyte and CD34+ stem cells, data has been analysed from the UK NEQAS for Leucocyte Immunophenotyping schemes. The inter-laboratory CVs for CD4+ T lymphocyte counts were consistently lower for single-platform (mean 13.7%, range 10-18.3%) compared to dual-platform methodology (mean 23.4%, range 14.5-43.7%). Subgroup analysis of single-platform users demonstrated mean overall inter-laboratory CVs of 17.2%, 13% and 7.1% for the FlowCount, TruCount and volumetric approach respectively. The lowest inter-laboratory CVs obtained for a single sample by each single platform approach were 4% (TruCount), 4.4% (volumetric), 4.6% (FACSCount) and 12.7% (FlowCount). Similarly, the mean inter-laboratory CV for CD34+ stem cell enumeration using non-standardized single-platform approaches was 18.6% (range 3.1-36.9%) compared to 28.6% (range 19-44.2%) for the dual-platform technology. Our results suggest absolute cell subset enumeration should be performed by single-platform technology and that such an approach should improve the quality control of multi-centre clinical trial data for CD4+ T lymphocyte and CD34+ stem cells.

Antigens, CD34↗

Expression and distribution of leptospiral outer membrane components during renal infection of hamsters.

The outer membrane of pathogenic Leptospira species grown in culture media contains lipopolysaccharide (LPS), a porin (OmpL1), and several lipoproteins, including LipL36 and LipL41. The purpose of this study was to characterize the expression and distribution of these outer membrane antigens during renal infection. Hamsters were challenged with host-derived Leptospira kirschneri to generate sera which contained antibodies to antigens expressed in vivo. Immunoblotting performed with sera from animals challenged with these host-derived organisms demonstrated reactivity with OmpL1, LipL41, and several other proteins but not with LipL36. Although LipL36 is a prominent outer membrane antigen of cultivated L. kirschneri, its expression also could not be detected in infected hamster kidney tissue by immunohistochemistry, indicating that expression of this protein is down-regulated in vivo. In contrast, LPS, OmpL1, and LipL41 were demonstrated on organisms colonizing the lumen of proximal convoluted renal tubules at both 10 and 28 days postinfection. Tubular epithelial cells around the luminal colonies had fine granular cytoplasmic LPS. When the cellular inflammatory response was present in the renal interstitium at 28 days postinfection, LPS and OmpL1 were also detectable within interstitial phagocytes. These data establish that outer membrane components expressed during infection have roles in the induction and persistence of leptospiral interstitial nephritis.

Animals↗

Family protective factors among urban African American youth.

Examined the relations among family protective factors, stressful events, and behavioral adjustment of 64 African American 6th graders. The youths reported on family stressors, father-figure involvement, and kin support. Their primary caregivers reported on parenting, father-figure involvement, and family stressors. Teachers reported on child social skill deficits, acting out, and shy or anxious behavior. Based on regression analyses, stress exposure associated positively with child social skill deficits, acting out, and shy or anxious behavior. Parental warmth was associated negatively with shy or anxious behavior. Parental use of corporal punishment was associated positively with child acting out. For youth exposed to high numbers of family stressors, parental demandingness was associated negatively with child acting out and kin support was associated negatively with acting out and shy or anxious behavior, suggesting that these family factors partially shield children from the negative effects of stress.

Adolescent↗

Leaves online.

Explore the source record for details and available documents.

Choice Behavior↗

It's a bug's life.

Explore the source record for details and available documents.

Chronology as Topic↗

Hiring a new optometrist? Be prepared!

Bringing a new optometrist into a practice, even if only on an employer-employee basis, is a complicated process that should not be taken lightly by hirer or hiree. This article explores the many aspects of the process and the relationship that must be understood and worked out in advance.

Communication↗

Electrodeposited polytyramine as an immobilisation matrix for enzyme biosensors.

The application of an electrodeposited polytyramine film as an immobilisation matrix for the construction of enzyme biosensors is described. Glucose oxidase (used as a model enzyme) is covalently attached to free amine groups on the polytyramine film using the coupling reagents 1-ethyl-3(3-dimethylaminopropyl) carbodiimide hydrochloride and N-hydroxysuccinimide. The resultant recognition interface consisted of multilayers of GOx immobilised onto the polymer surface. This method of constructing enzyme biosensors is shown to produce a highly reproducible and stable device. The biosensor showed no loss in electrode response after four months of dry storage and exhibited only minor loss in response after 20 days of repeated use. The resultant biosensor had a linear range of 0.1-28 mM glucose and a detection limit of 0.01 mM.

Biosensing Techniques↗

Flow cytometric quantitation of immunofluorescence intensity: problems and perspectives. European Working Group on Clinical Cell Analysis.

Quantitation of immunofluorescence intensity serves to estimate the number of defined molecules expressed on or in cells. Clinical applications of this diagnostic tool are increasing, e.g., aberrant expression of various antigens (Ag) by leukemic blasts or lymphoma cells, intensity of CD38 expression by CD8+ T-lymphocytes to monitor activation status, and intensity of CD62P to detect platelet activation. In this report we discuss the quality-control measures required for quantitation of fluorescence intensity, and we review seven concepts that have been developed to quantify fluorescence intensity during the past 15 years. Initial work addressed the conversion of logarithmic channel numbers into units of relative fluorescence. The design and use of calibration beads labeled with predefined amounts of dye allowed instrument-independent expression of fluorescence intensity in units of molecules of equivalent soluble fluorochrome (MESF). This method was refined by the combined use of such standards with monoclonal antibodies (mAb) conjugated 1:1 with phycoerythrin (PE), allowing translation of fluorescence intensity into numbers of antibodies bound per cell. Alternatively, the use of 1:1 PE-conjugated mAb under the assumption that CD4+ lymphocytes reproducibly bind 50,000 CD4 mAb molecules was proposed to convert units of relative fluorescence intensity into units of antibodies bound per cell. The use of antibody-binding capacity as a surrogate marker for quantification of Ag expression was addressed more directly by the development of antibody-binding standards. The quantitative indirect immunofluorescence assay is based on beads labeled with various amounts of CD5 mAb that calibrate the binding of the secondary antibody in units of antibody-binding capacity. Alternatively, goat anti-mouse-labeled calibration beads have been developed. Published results obtained with the latter calibrators showed an unexpected inaccuracy. The different ways in which calibrators and cells under study bind mAb (i.e., Fab mediated versus Fc mediated) may have contributed to this variation. Recently, the use of stabilized cell populations expressing Ag in a specified range of concentrations has been proposed as an Ag-specific calibration system of mAb binding. We identify several issues on the level of instrumentation, reagents, and cells under study that should be solved to allow standardization of quantitative assessments of immunofluorescence intensity.

Animals↗

Flow cytometric enumeration of CD34+ hematopoietic stem and progenitor cells. European Working Group on Clinical Cell Analysis.

The need for a rapid and reliable marker for the engraftment potential of hematopoietic stem and progenitor cell (HPC) transplants has led to the development of flow cytometric assays to quantitate such cells on the basis of their expression of CD34. The variability associated with enumeration of low-frequency cells (i.e., as low as 0.1% or 5 cells/microl) is exceedingly large, but recent developments have improved the accuracy and precision of the assay. Here, we review and compare the major techniques. Based on the current state of the art, we recommend 1) bright fluorochrome conjugates of class II or III monoclonal antibodies (mAbs) that detect all glycoforms of CD34, 2) use of a vital nucleic acid dye to exclude platelets, unlysed red cells, and debris or use of 7-amino actinomycin D to exclude dead cells during data acquisition, 3) counterstaining with CD45 mAb to be included in the definition of HPC, 4) during list mode data analysis, Boolean gating to resolve the CD34+ HPCs from irrelevant cell populations on the basis of the low levels of CD45 expression and low sideward light-scatter signals of HPCs, 5) inclusion of CD34dim and CD34bright populations in the CD34+ cell count, 6) omission of the negative control staining, and 7) for apheresis products, enumeration of at least 100 CD34+ cells to ensure a 10% precision. Unresolved technical questions are 1) the replacement of conventional dual-platform by single-platform assay formats, i.e., derivation of absolute CD34+ cell counts from a single flow cytometric assessment instead of from combined flow cytometer (percent CD34+) and hematology analyzer (absolute leukocyte count) data, 2) the cross-calibration of the available single-platform assays, and 3) the optimal method for sample preparation. An important clinical question to be addressed is the definition of the precise phenotypes and required numbers of HPCs responsible for short- and long-term recovery to optimize HPC transplant strategies.

Antigens, CD34↗