A method for measurement of oxygen uptake in neonates.

The frequent use of continuous positive airway pressure and positive end-expiratory pressure in newborn infants with pulmonary disease has prevented the use of conventional methods for measuring oxygen uptake (VO2) in intensive-care units. A feed-back replenishment technique for the determination of the oxygen uptake of these newborn infants has been developed. An instrument utilizing this method has been designed and built permitting continuous VO2 monitoring without interfering in the routine ventilatory therapy of the critically ill infant. Theoretical, bench, and animal experiments using room air as an inspired gas indicate instrument accuracies as a percentage of full scale of 2.4, 2.8, and 7.3, respectively. Preliminary trials on infants demonstrate that the instrument functions satisfactorily in the newborn intensive-care unit.

Biomedical Engineering↗

Instrumentation for monitoring oxygen consumption using a replenishment technique.

An instrument to measure patient oxygen consumption simply and accurately has been built using a replenishment technique. Oxygen is added to the patient's exhaled gas until its oxygen concentration is the same as the oxygen concentration of the inhaled gas. The rate at which oxygen is added is a measure of the patient's oxygen consumption. Bench tests show that oxygen consumption is measured with an accuracy of +/- 2.3 percent and human tests show an accuracy of +/- 5.9 percent. The instrument interfaces easily with a mechanical ventilator and is readily accepted by the clinician.

Humans↗

The NerveSeeker: a system for automated nerve localization.

BACKGROUND AND OBJECTIVES: The NerveSeeker is a new instrument for locating peripheral nerves. Like existing nerve stimulators, it is based on injecting current through the needle used for drug injection. However, the NerveSeeker was designed to automatically adjust the amplitude of the stimulating current pulses. It does this by feedback control to hold the level of response constant at a small but reliably detectable fraction of a maximal neural response. We report experimental tests of the NerveSeeker using an excised frog nerve in a transparent chamber, where we could observe the needle approach. METHODS: A control voltage proportional to the stimulus magnitude was used to indicate the proximity of the needle tip to the nerve. The proximity was validated by direct measurement of the distance from the tip of the needle to the nerve. Parameters governing the performance of the NerveSeeker in tracking needle movement were analyzed. RESULTS: The following combined strategy was found effective: As the needle approached the nerve, the stimulus was reduced in proportion to the amplitude of the recorded response; as the needle moved away, the stimulus magnitude was incremented by a constant amount (enough to increase the neural response by approximately 1% of its maximum amplitude) after each stimulus that failed to elicit a neural response exceeding the criterion value. Stimulation throughout simulated penetrations was at a frequency of 10 Hz or higher to give more immediate guidance during insertion. Optimal settings for each control parameter were determined, reflecting both engineering and physiologic tradeoffs. With these settings, the device proved successful in localizing nerves, closely tracking needle movements at velocities as high as 2 mm/second. CONCLUSION: These experimental results suggest that clinical tests of the NerveSeeker would be appropriate.

Action Potentials↗

A new surgical monitoring and resuscitation cart.

To enhance patient safety after cardiac surgery, a new surgical cart has been designed to allow monitoring and resuscitation during transport of patients from operating room to intensive care unit.

Cardiac Surgical Procedures↗

Microprocessors in intensive care medicine.

Three specific applications of microprocessors to intensive care instrumentation are presented. Automatic feedback control of mechanical ventilation is achieved using end-tidal carbon dioxide concentration, oxygen consumption, and carbon dioxide production as the input control parameters. Closed-loop control of fluid infusion is used for resuscitating burn patients; intravenous infusion rate is microprocessor controlled to maintain a desired urine output. Metabolic rate is measured by indirect calorimetry using a microprocessor to compute the results and control the measuring instrumentation. These examples show how microprocessor technology has been used to expand instrumentation capability and implement feedback control. These systems use multiple-input feedback control, user guidance, automatic calibration, self-diagnostics, and intelligent alarms.

Computers↗