Search PubMed⌕ Search

Biomedical subjects

D B Phillips

Publications and source records attributed to D B Phillips.

3 recordsLinked to original sources

A multimedia perioperative record keeper for clinical research.

OBJECTIVE: To develop a multimedia perioperative recordkeeper that provides: 1. synchronous, real-time acquisition of multimedia data, 2. on-line access to the patient's chart data, and 3. advanced data analysis capabilities through integrated, multimedia database and analysis applications. DESIGN: To minimize cost and development time, the system design utilized industry standard hardware components and graphical. software development tools. The system was configured to use a Pentium PC complemented with a variety of hardware interfaces to external data sources. These sources included physiologic monitors with data in digital, analog, video, and audio as well as paper-based formats. DEVELOPMENT: The development process was guided by trials in over 80 clinical cases and by the critiques from numerous users. As a result of this process, a suite of custom software applications were created to meet the design goals. The Perioperative Data Acquisition application manages data collection from a variety of physiological monitors. The Charter application provides for rapid creation of an electronic medical record from the patient's paper-based chart and investigator's notes. The Multimedia Medical Database application provides a relational database for the organization and management of multimedia data. The Triscreen application provides an integrated data analysis environment with simultaneous, full-motion data display. CONCLUSION: With recent technological advances in PC power, data acquisition hardware, and software development tools, the clinical researcher now has the ability to collect and examine a more complete perioperative record. It is hoped that the description of the MPR and its development process will assist and encourage others to advance these tools for perioperative research.

Database Management Systems↗

Sonographic investigation of flow patterns in the perfused human placenta and their modulation by vasoactive agents with enhanced visualization by the ultrasound contrast agent Albunex.

PURPOSE: Our objective was to demonstrate sonographically the flow distribution in the circulation of human placentae as well as the sensitivity of the human fetal capillary bed to vasoconstriction and dilatation. METHODS: Five human full-term placental lobules were maintained in vitro with fetal and maternal flow. Commercial ultrasound scanners were used for imaging. Albunex (1 ml bolus) was administered to the fetal "artery" to monitor patterns of flow. U46619 (1 ml, 10(-6) M; a thromboxane agonist and potent vasoconstrictor) and/or nitroglycerin (a potent vasodilator) were added to the fetal artery. RESULTS: Following the addition of U46619, mean "fetal pressures" rapidly rose from 23.2 +/- 0.8 to 118 +/- 2. 9 mm Hg (mean +/- standard error of mean; p < 0.001); venous flow rates decreased. As demonstrated by color Doppler imaging, flow markedly changed from a pattern of general distribution throughout the lobule to flow only near the chorionic plate. Color persistence was 94.4 +/- 6.5 seconds with Albunex after nitroglycerin and 39.8 +/- 3.4 seconds with Albunex after injection of U46619 (p < 0.001). Nitroglycerin had no effect when injected by itself but returned "constricted" flow to a "normal" pattern when injected after U46619. CONCLUSIONS: The contrast medium Albunex improved visualization of the fetal circulation throughout the lobule. Flow in the human placental capillary bed can be regionally manipulated throughout the placental lobule by vasomodulators and monitored by Albunex-enhanced sonographic examination.

15-Hydroxy-11 alpha,9 alpha-(epoxymethano)prosta-5↗