Search PubMed⌕ Search

Biomedical subjects

D B Olsen

Publications and source records attributed to D B Olsen.

At least 19 recordsLinked to original sources

Nucleoside analog inhibitors of hepatitis C virus replication.

Of the 30 compounds currently marketed in the United States for treatment of viral infections, 15 are nucleoside analogs, demonstrating the utility of this class of compound as a source of antiviral drugs. The success of nucleoside analogs in treating other viral infections provides a compelling rationale for the significant effort that is currently being devoted to the discovery and development of nucleoside analogs to treat infection by hepatitis C virus (HCV) that may lead to improvements in response rates compared to currently available therapies. Several different approaches have been adopted to identify promising analogs, including the use of surrogate viruses in cell culture assays, screening in the cell-based bicistronic HCV replicon assay, and screening nucleoside triphosphates for the ability to inhibit the activity of the HCV RNA-dependent RNA polymerase in vitro. Several classes of ribonucleoside analogs with modifications of the ribose inhibit HCV replication. Nucleoside analogs incorporating a 2'-C-methyl modification are potent inhibitors in the replicon assay in the absence of cytotoxicity, and appear to exert their inhibition by acting as functional chain terminators of RNA synthesis. NM283, a prodrug of 2'-C-methylcytidine, has entered clinical trials and demonstrated viral load reductions in subjects infected with genotype 1 HCV, a genotype known to be difficult to treat effectively with currently approved therapies. Overall, results to date offer encouragement that improved therapies to treat HCV infection including newly developed nucleoside analogs may become available within the next few years.

Animals↗

Heterogeneity in limb fatty acid kinetics in type 2 diabetes.

AIMS/HYPOTHESIS: In order to test the hypothesis that disturbances in skeletal muscle fatty acid metabolism with type 2 diabetes are not equally present in the upper and lower limbs, we studied fatty acid kinetics simultaneously across the arm and leg of type 2 diabetic patients (n=6) and matched control subjects (n=7) for 5 h under baseline conditions and during a 4-h hyperinsulinaemic-euglycaemic clamp. METHODS: Limb fatty acid kinetics was determined by means of continuous [U-(13)C]palmitate infusion and measurement of arteriovenous differences. RESULTS: The systemic palmitate rate of appearance was 3.6+/-0.4 and 2.7+/-0.3 micromol.kg lean body mass(-1).min(-1) and decreased during the clamp by 26% (p=0.04) and 43% (p<0.01) in the diabetic patients and in the control subjects respectively. At baseline, palmitate uptake across the arm was similar in the two groups, whereas leg palmitate uptake was lower than in the arm in the diabetic patients. During the clamp, palmitate uptake decreased in the arm (-48%, p=0.02) and the leg (-38%, p=0.04) of the control subjects, whereas it decreased in the arm (-30%, p=0.04) but not in the leg of the diabetic patients. Similarly, during the clamp palmitate release was substantially suppressed in the arm (-47%, p<0.01) and the leg of the control subjects (-45%, p<0.01), but only in the arm of the diabetic patients (-45%, p<0.01). CONCLUSIONS/INTERPRETATION: The present data indicate that type 2 diabetes is characterised by heterogeneity in the dysregulation of skeletal muscle fatty acid metabolism, with only the leg, but not the arm, showing an impairment of fatty acid kinetics at baseline and during a hyperinsulinaemic-euglycaemic clamp causing a physiological increase in insulin concentration.

Arm↗

Interleukin-6 and tumor necrosis factor-alpha are not increased in patients with Type 2 diabetes: evidence that plasma interleukin-6 is related to fat mass and not insulin responsiveness.

AIMS/HYPOTHESIS: Our aim was to examine the possible direct relationship of interleukin-6 and TNFalpha with insulin sensitivity in humans. METHODS: We carried out two series of euglycaemic-hyperinsulinaemic clamp experiments. In the first (CLAMP1), skeletal muscle mRNA expression and plasma concentrations of IL-6 and TNFalpha were examined in patients with Type 2 diabetes ( n=6), subjects matched for age (n=6), and young healthy (n=11) control subjects during a 120-min supra-physiological hyperinsulinaemic (40 mU.m(-2).min(-1)) euglycaemic clamp. In the second series of experiments (CLAMP2), patients with Type 2 diabetes (n=6) and subjects matched for age (n=7) were studied during a 240-min high-physiological hyperinsulinaemic (7 mU.m(-2).min(-1)) euglycaemic clamp, during which arterial and venous (femoral and subclavian) blood samples were measured for IL-6 and TNFalpha flux. RESULTS: In both experiments the glucose infusion rate in the patients was markedly lower than that in the other groups. In CLAMP1, basal skeletal muscle IL-6 and TNFalpha mRNA were the same in all groups. They were not affected by insulin and they were not related to the glucose infusion rate. In CLAMP2, neither cytokine was released from the arm or leg during insulin stimulation in either group. In both experiments plasma concentrations of these cytokines were similar in the patients and in the control subjects, although in CLAMP1 the young healthy control group had lower (p<0.05) plasma IL-6 concentrations. Using data from all subjects, a strong positive correlation (r=0.85; p<0.00001) was observed between basal plasma IL-6 and BMI. Conversely, a negative relationship (r=-0.345; p<0.05) was found between basal plasma TNFalpha and BMI, although this was not significant when corrected for BMI. When corrected for BMI, no relationship was observed between either basal plasma IL-6 or TNFalpha and GIR. CONCLUSIONS/INTERPRETATION: These data show that the increased circulating IL-6 concentrations seen in patients with Type 2 diabetes are strongly related to fat mass and not insulin responsiveness, and suggest that neither IL-6 nor TNFalpha are indicative of insulin resistance.

Adipose Tissue↗

Design of a continuous flow centrifugal pediatric ventricular assist device.

Thousands of pediatric patients suffering from cardiomyopathy or single ventricular physiologies secondary to debilitating heart defects may benefit from long-term mechanical circulatory support due to the limited number of donor hearts available. This article presents the initial design of a fully implantable centrifugal pediatric ventricular assist device (PVAD) for 2 to 12 year olds. Conventional pump design equations, including a nondimensional scaling approach, enabled performance estimations of smaller scale versions (25 mm and 35 mm impeller diameters) of our adult support VAD. Based on this estimated performance, a computational model of the PVAD with a 35 mm impeller diameter was generated. Employing computational fluid dynamics (CFD) software, the flow paths through the PVAD and overall performance were analyzed for steady state flow conditions. The numerical simulations involved flow rates of 2 to 5 LPM for rotational speeds of 2750 to 3250 RPM and incorporated a k-epsilon fluid turbulence model with a logarithmic wall function to characterize near-wall flow conditions. The CFD results indicated best efficiency points ranging from 25% to 28%, which correlate well with typical values of blood pumps. The results further demonstrated that the pump could deliver 2 to 5 LPM at 70 to 95 mmHg for desired physiologic conditions in resting 2 to 12 year olds. Scalar stress levels remained below 300 Pa, thereby signifying potentially low levels of hemolysis. Several flow regions in the pump exhibited signs of vortices, retrograde flow, and stagnation points, which require optimization and further study. This CFD model represents a reasonable starting point for future model enhancements, leading to prototype manufacturing and experimental validation.

Child↗

Identification of MK-944a: a second clinical candidate from the hydroxylaminepentanamide isostere series of HIV protease inhibitors.

Recent results from human clinical trials have established the critical role of HIV protease inhibitors in the treatment of acquired immune-deficiency syndrome (AIDS). However, the emergence of viral resistance, demanding treatment protocols, and adverse side effects have exposed the urgent need for a second generation of HIV protease inhibitors. The continued exploration of our hydroxylaminepentanamide (HAPA) transition-state isostere series of HIV protease inhibitors, which initially resulted in the identification of Crixivan (indinavir sulfate, MK-639, L-735,524), has now yielded MK-944a (L-756,423). This compound is potent, is selective, and competitively inhibits HIV-1 PR with a K(i) value of 0.049 nM. It stops the spread of the HIV(IIIb)-infected MT4 lymphoid cells at 25.0-50.0 nM, even in the presence of alpha(1) acid glycoprotein, human serum albumin, normal human serum, or fetal bovine serum. MK-944a has a longer half-life in several animal models (rats, dogs, and monkeys) than indinavir sulfate and is currently in advanced human clinical trials.

Animals↗

Combinatorial diversification of indinavir: in vivo mixture dosing of an HIV protease inhibitor library.

An efficient combination solution-phase/solid-phase route enabling the diversification of the P1', P2', and P3 subsites of indinavir has been established. The synthetic sequence can facilitate the rapid generation of HIV protease inhibitors possessing more favorable pharmacokinetic properties as well as enhanced potencies. Multiple compound dosing in vivo may also accelerate the identification of potential drug candidates.

Animals↗

Numerical analysis of blood flow in the clearance regions of a continuous flow artificial heart pump.

The CFVAD3 is the third prototype of a continuous flow ventricular assist device being developed for implantation in humans. The pump consists of a fully shrouded 4-blade impeller supported by magnetic bearings. On either side of this suspended rotating impeller is a small clearance region through which the blood flows. The spacing and geometry of these clearance regions are very important to the successful operation of this blood pump. Computational fluid dynamics (CFD) solutions for this flow were obtained using TascFlow, a software package available from AEA Technology, U.K. Flow in these clearance regions was studied parametrically by varying the size of the clearance, the blood flow rate into the pump, and the rotational speed of the pump. The numerical solutions yield the direction and magnitude of the flow and the dynamic pressure. Experimentally measured pump flow rates are compared to the numerical study. The results of the study provide guidance for improving pump efficiency. It is determined that current clearances can be significantly reduced to improve pump efficiency without negative impacts.

Computer Simulation↗

An alternate binding site for the P1-P3 group of a class of potent HIV-1 protease inhibitors as a result of concerted structural change in the 80s loop of the protease.

Structures of the complexes of HIV protease inhibitor L--756,423 with the HIV-1 wild-type protease and of the inhibitors Indinavir, L-739,622 and Saquinavir with the mutant protease (9X) containing nine point mutations (Leu10Val, Lys20Met, Leu24Ile, Ser37Asp, Met46Ile, Ile54Val, Leu63Pro, Ala71Val, Val82Thr) have been determined. Comparative analysis of these structures reveals an alternate binding pocket for the P1-P3 group of Indinavir and L--756, 423. The alternate binding pocket is a result of concerted structural change in the 80s loop (residues 79-82) of the protease. The 80s loop is pulled away from the active site in order to accommodate the P1-P3 group, which is sandwiched between the flap and the 80s loop. This structural change is observed for the complexes of the wild type as well as the 9X mutant protease. The study reveals that the 80s loop is an intrinsically flexible loop in the wild-type HIV-1 protease and that mutations in this loop are not necessary to result in conformational changes. Conformation of this loop in the complex depends primarily upon the nature of the bound inhibitor and may be influenced by mutations in the protease. The results underscore the need to understand the intrinsic structural plasticity of the protease for the design of effective inhibitors against the wild-type and drug-resistant enzyme forms. In addition, the alternate binding pocket for the P1-P3 group of Indinavir and L--756,423 may be exploited for the design of potent inhibitors.

Amino Acid Substitution↗

Non-active site changes elicit broad-based cross-resistance of the HIV-1 protease to inhibitors.

Three high level, cross-resistant variants of the HIV-1 protease have been analyzed for their ability to bind four protease inhibitors approved by the Food and Drug Administration (saquinavir, ritonavir, indinavir, and nelfinavir) as AIDS therapeutics. The loss in binding energy (DeltaDeltaG(b)) going from the wild-type enzyme to mutant enzymes ranges from 2.5 to 4.4 kcal/mol, 40-65% of which is attributed to amino acid substitutions away from the active site of the protease and not in direct contact with the inhibitor. The data suggest that non-active site changes are collectively a major contributor toward engendering resistance against the protease inhibitor and cannot be ignored when considering cross-resistance issues of drugs against the HIV-1 protease.

Binding Sites↗

[Neuropsychiatric disorders in insulinoma].

The case of a young female presenting severe mental problems and episodic neurological symptoms is described. Obsessive-compulsive disorder was diagnosed upon psychiatric treatment for eight months. No neurological condition was found. Hypoglycaemia was observed during an episode of long-lasting somnolescence and the patient referred for endocrinological examination. Reactive hypoglycaemia was ruled out in an oral glucose tolerance test. A test of prolonged starvation revealed hypoglycaemia associated with neuropsychiatric symptoms. Glucose abolished this condition, suggesting an insulinoma as the basis of the spontaneous hypoglycaemia. Subsequently, two insulinomas were resected from the tail of the pancreas. The patient has recovered completely after her surgery, with no signs of mental or neurological disease and blood glucose within normal limits. As insulinoma is often associated to the MEN1-syndrome, the patient and her relatives are now being investigated for this condition.

Adult↗

A ventricular assist device powered by conditioned skeletal muscle.

BACKGROUND: We are developing and testing a new ventricular assist device (VAD) to be powered by conditioned skeletal muscle. METHODS: To evaluate the VAD hardware and to develop a muscle training regimen, 8 calves have been used in studies in which the right latissimus dorsi muscle was employed. The experiments were carried out to an approximately 4-month duration. RESULTS: There was significant conversion of type II (fast twitch) to type I (slow twitch) muscle fibers. This did not correlate well, however, with device performance. The device stroke volumes ranged from approximately 17 to 90 cc. This variability of outcome occurred despite the fact that identical hardware, surgical procedures, and training regimens were employed. CONCLUSIONS: The results from the first eight studies lead us to speculate that perfusion may be important even when the muscle is working at pressures much lower than systemic blood pressure levels. In an attempt to augment tissue perfusion, we plan to investigate thermally induced angiogenesis as a possible mechanism for increasing blood flow to the tissue.

Animals↗

The DeBakey ventricular assist device: current status in 1997.

In 1993, the development began of a small axial flow blood pump, the DeBakey ventricular assist device (VAD). The material was recently converted to a titanium alloy, and a waterproof pump package was incorporated for long-term intracorporeal circulation. Thirteen intrathoracic implantations in calves were achieved. Nine animals survived the 2 week perioperative period and were supported for a range of 26-93 days. The first study had low flow due to poor anatomical fit of the straight cannula. In contrast, a curved cannula used subsequently provided a good anatomical fit with sufficient flow. Mean flow of 4.4 L/min was sustained with 9,900 rpm and required power was an average of 8.8 W. No thromboembolic evidences were observed in any case, and the plasma free hemoglobin level was maintained lower than 5 mg/dl, except in the early postoperative period. Three animals were terminated because of bleeding due to anticoagulant mismanagement. Electric interference (n = 1) and drive line breakage/fault (n = 2) were observed as device-related failures. Minor modifications were made to the drive line. In conclusion, the DeBakey VAD demonstrated adequate basic performance and biocompatibility. The highly reliable mechanical components and improved electrical parts are promising for a long-term implantable cardiac prosthesis.

Animals↗

Blood flow in a continuous flow ventricular assist device.

A numerical analysis was performed to predict the shear stresses, flow rates, and the velocity profiles in a continuous flow ventricular assist device, the CFVAD3. The problem was modeled as a rotating disk over a stationary disk. A variety of clearances was tested for the CFVAD3 coupled with a range of rotational speeds and pressure gradients. Velocity fields were generated using solutions obtained with FLOW3D software (AEA Technology, Pittsburgh, PA, U.S.A.) Analysis of these solutions shows that the pressure differential effect has a stronger influence on the flow than the rotational effect of the impeller Ekman layer. The predicted shear stresses reflect these changes in the volume flow rates and the speeds shown in the velocity profiles. Based on the predictions of the software, the optimum clearance and rotational speed were chosen. The conclusion is that a speed in the range of 2,200-2,400 rpm should be chosen depending on the efficiency of the pump.

Blood Flow Velocity↗

Chronic survival of calves implanted with the DeBakey ventricular assist device.

The DeBakey ventricular assist device (VAD) is a miniaturized, electromagnetically driven axial flow pump capable of generating in excess of 10 L/min output. The VAD was evaluated in 19 calves during experiments designed to test iterative modifications in the system and to determine the safety of the DeBakey VAD for intermediate to long-term implant. Five of the animals died or were euthanized during the perioperative period (i.e., Days 1-5) due to complications associated with bleeding (n = 3), sudden cardiac arrest (n = 1), or pump occlusion due to a muscle remnant associated with coring (n = 1). The remaining 14 animals survived from 7-145 days. Ten of the 14 animals survived 30 or more days, and 2 animals survived 93 and 145 days before elective euthanasia. Pump function was evaluated in the 14 calves that survived beyond the perioperative period. Pump output at implantation averaged 3 L/min while output at 100 days (n = 2) averaged 4.22 L/min. The electrical current did not change across time during the study, indicating normal operation of the bearings. Pumps consumed less than 10.5 W of power for all support durations. Hemolysis did not occur; the average daily plasma free hemoglobin varied from 2.0 to 8.0 mg/dl. Evaluation of serum biochemical data showed that implantation of the DeBakey VAD in calves with normal hearts did not impair end organ function; BUN, creatinine, and total bilirubin varied minimally within the normal range. The white blood cell count of implanted animals remained within the normal range throughout the study.

Animals↗