Search PubMed⌕ Search

Biomedical subjects

D B Longmore

Publications and source records attributed to D B Longmore.

At least 19 recordsLinked to original sources

Glagov remodeling of the atherosclerotic aorta demonstrated by cardiovascular magnetic resonance: the CORDA asymptomatic subject plaque assessment research (CASPAR) project.

BACKGROUND: Aortic atherosclerosis and coronary artery disease (CAD) are closely linked. Early detection of aortic atherosclerosis with the adoption of appropriate preventive measures may therefore help to reduce mortality and morbidity related to CAD. Arterial remodeling, by which the wall adapts to physiological or pathological insults by a change in vessel size, is being increasingly recognized as an important aspect of atherosclerosis. In this prospective longitudinal study we used cardiovascular magnetic resonance (CMR) to detect aortic plaque and to study aortic wall remodeling in asymptomatic subjects. METHODS: We recruited 175 healthy volunteers (49 years, 110 men) and documented their cardiovascular risk profile. Each subject underwent echocardiogram (ECG)-gated T1-weighted spin-echo imaging of the infrarenal abdominal aorta at baseline and after 2 years. FINDINGS: Of the 175 subjects who volunteered at baseline, CMR was successful in 174 (99%), with one (0.6%) failure due to claustrophobia. At 2 years, follow-up scanning was performed in 169 subjects (97%). Infrarenal aortic plaque was identified at baseline in nine (5.2%) subjects. This was reconfirmed in all nine (100%) cases at 2-year follow-up. No new cases of infrarenal plaque were identified at follow-up. The signal characteristics of the plaque on the subtracted images of the Dixon method indicate that all plaques were fibrous. In the nine subjects with infrarenal plaque, the total plaque burden increased as assessed by the total wall volume (561 to 677 mm3, p = 0.0063). The total vessel volume also increased (1737 to 1835 mm3, p = 0.031) but there was no change in the total luminal volume (1175 to 1157 mm3, p = 0.29). CONCLUSIONS: Cardiovascular magnetic resonance detects subclinical aortic atherosclerosis, can follow plaque burden over time, and confirms the presence of Glagov remodeling with preservation of the lumen despite progression of plaque. Cardiovascular magnetic resonance is well suited for the longitudinal follow-up of the general population with atherosclerosis, may help in the understanding of the natural history of atherosclerosis, and in particular may help determine factors to retard disease progression at an early stage.

Aorta, Abdominal↗

Optimization of magnetic resonance imaging parameters for left ventricular wall motion studies at 0.5 T.

Magnetic resonance cine imaging of left ventricular wall motion at rest or during stress may be used to assess myocardial function, infarction and viability, or reversible ischaemia. Whilst interpretation of the cines rests critically on image quality, there is little in the literature which systematically examines the optimal imaging parameters for such wall motion studies at rest or during stress. This study was designed to examine several imaging parameters for cine optimization using a conventional 0.5 T scanner. Gradient echo imaging was performed in two groups of volunteers with varying echo times and flip angles. The period between excitations was 80 ms (simulating a resting heart rate) in one group, and 40 ms (simulating tachycardia during stress) in the other group. Short axis imaging yielded the highest contrast between blood and myocardium for both repetition times (rest p = 0.02; stress p < 0.001) compared with the long axes, because of magnetic saturation of blood moving slowly in-plane. Contrast was higher at end-diastole than end-systole for the long axes (rest p < 0.0001; stress p < 0.0002), but not significantly different in the short axis. Increasing the echo time and flip angle resulted in increased signal but eventually caused motion artefact and magnetic saturation of blood. The optimal parameters were an echo time of 14 ms and a 45 degrees flip angle for resting heart rates, with the flip angle falling to between 35 degrees and 45 degrees for tachycardia. The choice of imaging parameters is therefore a compromise between improved signal and unwanted artefacts, although the latter are less evident in the short axis plane, which yields the best contrast results because of high blood inflow effects.

Adult↗

Assessment of magnetic resonance velocity mapping of global ventricular function during dobutamine infusion in coronary artery disease.

BACKGROUND: Magnetic resonance imaging (MRI) is a versatile technique for examination of the cardiovascular system but only recently has assessment of myocardial ischaemia in coronary artery disease (CAD) become possible, for example by demonstrating abnormalities of regional ventricular contraction during stress. Global ventricular function during stress was assessed by MRI of aortic flow, which has not been previously attempted. DESIGN: Variables measured by MRI reflecting the effect of ischaemia on global ventricular function during dobutamine stress were correlated with thallium-201 myocardial perfusion tomography. PATIENTS: 10 normal controls and 25 patients with CAD. SETTING: Tertiary cardiac referral centre. METHODS: Novel MRI sequences and analysis systems were used to measure the following variables during staged dobutamine infusion to 20 micrograms/kg/min: stroke volume, cardiac output, cardiac power output, peak flow, peak flow acceleration, aortic back flow, and flow wave velocity. Heart rate, blood pressure, double product, and maximum tolerated dobutamine dose were also measured. Multiple regression analysis was used to compare changes during stress with 201TI tomography. RESULTS: All parameters except for stroke volume and diastolic blood pressure increased in the controls. In the patients with CAD a significant relation was shown between the extent of reversible ischaemia and the change in peak flow acceleration (P < 0.00001), peak flow (P = 0.002), cardiac power output (P = 0.036), maximum dobutamine dose (P = 0.039), and systolic blood pressure (P = 0.04). Peak flow acceleration accounted for 58.4% of the variation in reversible ischaemia, and after allowing for this, only cardiac power output remained independently predictive adding a further 4.2% to the model (adjusted r2 = 0.626). A decrease in peak flow acceleration with an increase in dobutamine infusion indicated moderate or severe ischaemia (chi 2 = 10.2, P = 0.017). CONCLUSION: MRI may be used to assess variables of aortic flow during stress, which includes acceleration with high temporal resolution. Peak flow acceleration was the most sensitive indicator of the effect of ischaemia on global ventricular function.

Adult↗

Real time blood flow imaging by spiral scan phase velocity mapping.

The work describes the development of a novel sequence that uses rapid spiral k-space sampling, combined with phase velocity mapping, for real time flow velocity imaging. The performance of the technique is assessed on phantoms for both through-plane and in-plane flows. The flow measurements compared well with those measured using a bucket and stopwatch. One advantage of the technique is that flow related signal loss is minimal due to the early acquisition of the center of k-space data. Flow artifacts were observed for in-plane flow and these were understood with the aid of computer simulations. In vivo studies involved cine velocity mapping in normal volunteers; aortic blood flow waveforms acquired by spiral scanning in two cardiac cycles compared well with data from a conventional gradient-echo sequence. Potential applications of the method are demonstrated by studying the response of aortic flow to physical exercise and the real time monitoring of aortic flow during a valsalver maneuver.

Algorithms↗

Technical note: rapid measurement of left ventricular mass by spin echo magnetic resonance imaging.

Magnetic resonance (MR) imaging provides an accurate measurement of left ventricular mass but imaging time can be up to 45 min. We tested a more rapid multislice spin echo technique on 16 volunteers without evidence of heart disease. Multislice short axis spin echo images were acquired in up to three sets of five, clustered around end systole. Total imaging time was 15 min. Myocardial areas were summed and specific gravity was assumed. Comparison was made with multiple single acquisitions timed to end systole. There was good agreement between the two measurements of left ventricular mass. Mean (+/- standard deviation (sd), range) values were 212 g (+/- 41.71, 152 to 311) by the multislice method and 213 g (+/- 44.26, 155 to 317) by the single slice method. The mean difference (+/- sd of difference) between measurements was -1.72 +/- 14.89 g (95% confidence interval for limits of agreement was +/- 14%). We have therefore established a more rapid and accurate method of measuring left ventricular mass.

Adult↗

Magnetic resonance volume flow and jet velocity mapping in aortic coarctation.

OBJECTIVES: Nuclear magnetic resonance (MRI) velocity mapping was used to characterize flow waveforms and to measure volume flow in the ascending and descending thoracic aorta in patients with aortic coarctation and in healthy volunteers. We present the method and discuss the relation between these measurements and aortic narrowing assessed by MRI. Finally, we compare coarctation jet velocity measured by MRI velocity mapping with that obtained from continuous wave Doppler echocardiography. BACKGROUND: The development of a noninvasive imaging method for morphologic visualization of aortic coarctation and for measurement of its impact on blood flow is highly desirable in the preoperative and postoperative management of patients. METHODS: Magnetic resonance imaging phase-shift velocity mapping was used to measure ascending and descending aortic volume flow in 39 patients with aortic coarctation and in 12 healthy volunteers. Magnetic resonance imaging was also used for anatomic and peak jet velocity measurements. The latter were compared with those available from continuous wave Doppler study in 40% of the patients. RESULTS: Whereas ascending aortic volume flow measurement did not show significant differences between the patient and healthy control groups, volume flow curves in the descending aorta did show significant differences between the two groups. Peak volume flow (mean +/- SD) was 10.6 +/- 5.3 liters/min in patients and 19.6 +/- 4.7 liters/min in control subjects (p < 0.001). Time-averaged flow was 2.5 +/- 0.9 liters/min in patients and 3.9 +/- 1.1 liters/min in control subjects (p < 0.05). The descending/ascending aorta flow ratio was 0.47 +/- 0.19 in patients and 0.64 +/- 0.08 in control subjects (p < 0.05). These variables correlate well with the degree of aortic narrowing. Peak coarctation jet velocity measured by MRI velocity mapping is comparable to that obtained from continuous wave Doppler study (r = 0.95). CONCLUSIONS: We established normal ranges for volume flow in the descending aorta and demonstrated abnormalities in patients with aortic coarctation. These abnormalities are likely to be related to resistance to flow imposed by the coarctation and could represent an additional index for monitoring patients before and after intervention.

Adolescent↗

Magnetic resonance assessment of the pulmonary arterial trunk anatomy, flow, pulsatility and distensibility.

We used magnetic resonance imaging with cine velocity mapping to study the anatomy of pulmonary bifurcation and to measure volume blood flow, pulsatility of flow and arterial wall distensibility in the central pulmonary arteries of nine healthy volunteers. Multislice, multiplane spin echo images were acquired to display pulmonary bifurcation anatomy. Diameters of the main pulmonary artery (MPA) in systole were 2.56 +/- 0.35 cm and in diastole 2.20 +/- 0.33 cm. Those of the right pulmonary artery (RPA) were 1.57 +/- 0.29 cm and 1.39 +/- 0.23 respectively, and of the left pulmonary artery (LPA) 1.79 +/- 0.26 cm and 1.55 +/- 0.10 cm respectively. A gradient echo sequence with phase shift velocity mapping was then used to measure flow in MPA, RPA and LPA 2 cm on either side of the pulmonary bifurcation. Time averaged flow, calculated from mean velocity and the cross-sectional area of the vessels was 4.99 +/- 1.10 l.min-1 in MPA, 2.23 +/- 0.58 l.min-1 in RPA and 2.31 +/- 0.63 l.min-1 in LPA. The pulsatility index of flow derived from peak forward flow, peak backward flow and time averaged flow were as follows: MPA 4.4 +/- 0.8, RPA 5.1 +/- 0.6 and LPA 4.6 +/- 1.5. Distensibility, calculated from the change in cross-sectional area between diastole and systole and expressed as percentage were as follows: MPA 25.6 +/- 10.7, RPA 21.4 +/- 10.7 and LPA 24.5 +/- 7.8. MRI with velocity mapping accurately characterized anatomy, flow, distensibility and pulsatility of the central pulmonary arteries.

Adult↗

Magnetic resonance imaging of coronary arteries: technique and preliminary results.

BACKGROUND: Coronary artery imaging is an important investigation for the management of coronary artery disease. The only reliable technique presently available, x ray contrast angiography, is invasive and is associated with a small morbidity and mortality. Alternative non-invasive imaging would be useful, but the small calibre and tortuosity of the coronary vessels, and cardiac and respiratory motion create formidable imaging problems. OBJECTIVE: The development of rapid magnetic resonance imaging of the coronary arteries. PATIENTS: 21 healthy controls and five patients with coronary artery disease established by x ray contrast angiography, of whom two had undergone bypass grafting. METHODS: Magnetic resonance imaging was performed with gradient echoes and a segmented k-space technique, such that a complete image was acquired in 16 cardiac cycles during a breathhold. The signal from fat was suppressed and images were acquired in late diastole to reduce artefact from cardiac motion. An imaging strategy was developed for the proximal arteries, including longitudinal imaging from oblique planes defined according to the origins and the continuation of the arteries in the atrioventricular grooves or interventricular sulcus. RESULTS: Of the 26 subjects studied, 22 were imaged successfully. Identification of the artery was possible for the left main stem, left anterior descending, right coronary, and left circumflex arteries respectively in 95%, 91%, 95%, and 76%. The arterial diameter at the origin could be measured in 77%, 77%, 81%, and 63%. The mean (SD) arterial diameter in each case (4.8 (0.8), 3.7 (0.5), 3.9 (0.9), and 2.9 (0.6) mm) was not significantly different from reference values. The mean length of artery visualised was 10.4 (5.2), 46.7 (22.8), 53.7 (27.9), and 26.3 (17.5) mm. In 12 healthy men the total coronary area was 30.9 (9.2) mm2 and the ratio compared with body surface area was 16.4 (4.4) mm2m2 (both p = NS compared with reference values). In seven patients in whom x ray contrast coronary angiography was available, the proximal arterial diameter was 3.9 (1.1) mm measured by magnetic resonance and 3.7 (1.0) mm by x ray contrast angiography (p = NS). The mean difference between the measurements was 0.2 (0.5) mm, and the coefficient of variation was 13.7%. All five occluded coronary arteries were identified, as were all three vein grafts. In two patients insertion of the graft into the native arteries was identified. CONCLUSIONS: Magnetic resonance coronary angiography is feasible. Good results were obtained by a breath-hold, fat suppression technique, gated to late diastole. Arterial occlusions and vein grafts were readily identified. Further studies are required to establish its value in the detection of coronary stenosis and to develop the measurement of coronary flow velocity which could be used to quantify the severity of the stenosis.

Coronary Angiography↗

Age-related changes of human aortic flow wave velocity measured noninvasively by magnetic resonance imaging.

We have used magnetic resonance imaging with cine velocity mapping to measure flow wave velocity in the thoracic aorta of 20 healthy volunteers of different ages. We have also studied the relationship between propagation of flow wave velocity and regional aortic compliance. Aortic flow velocity increased linearly with age (r = 0.87), and there was a significant difference between the youngest decade [age 10-19, mean velocity 4.3 +/- 0.7 (SD) m/s] and the oldest decade studied (age 50-59, mean velocity 7.2 +/- 0.2 m/s). Flow wave velocity (m/s) was negatively correlated with ascending aortic compliance (microliter/mmHg) (r = -0.75). Magnetic resonance imaging is a noninvasive method for measurement of aortic flow wave velocity that is an important parameter in assessing arterial wall mechanics and blood flow dynamic.

Adolescent↗

Magnetic resonance jet velocity mapping in mitral and aortic valve stenosis.

BACKGROUND: Magnetic resonance (MR) phase-shift velocity mapping is an established method for measurement of nonturbulent intravascular flow. Shortening the echo time of the MR sequence to 3.6 msec allowed application of the technique to turbulent jet flow. The objective of this study was validation of MR jet velocity mapping in patients with cardiac valve stenosis. METHODS AND RESULTS: We used a 0.5-T Picker MR machine to measure peak poststenotic jet velocity in 15 consecutive patients recruited with known valve disease (six mitral stenosis, three of these restudied after valvoplasty, and 11 aortic stenosis). On the same day as the MR study, these patients underwent independent Doppler echocardiographic measurement of peak jet velocity. The results of 10 further MR investigations of aortic stenosis are also reported and compared with Doppler studies performed within 6 months. Of the 29 MR studies, 28 (97%) produced interpretable velocity maps, the one failure being attributed to misplacement of the imaging slice in a case of severe aortic stenosis. Agreement between MR and Doppler measurements of peak jet velocity in the recruited group was as follows: n = 18; range, 1.4-6.1 m/sec; mean, 3 m/sec; mean of differences (MR-Doppler), 0.23 m/sec; standard deviation of differences, 0.49 m/sec. CONCLUSIONS: In vivo MR peak jet velocity measurements agree well with those made by Doppler ultrasound. The technique, which is not subject to restricted windows of access and has potential for further refinements, could contribute to improved evaluation of stenoses, especially at locations where ultrasonic access is limited.

Aortic Valve Stenosis↗

Helical and retrograde secondary flow patterns in the aortic arch studied by three-directional magnetic resonance velocity mapping.

BACKGROUND: Helical and retrograde secondary flows have been recorded in the aorta, but their origins and movements in relation to the arch have not been clarified. We set out to do this using magnetic resonance velocity mapping. METHODS AND RESULTS: Three-directional phase contrast cine magnetic resonance velocity mapping was used to map multidirectional flow velocities in the aortas of 10 healthy volunteers. Computer processing was used to visualize flow vector patterns in selected planes. Right-handed helical flows predominated in the upper aortic arch in late systole, being clearly recognizable in 9 of the 10 subjects. Nonaxial components of velocity in this region reached 0.29 m/s (+/- 0.05 m/s) as axial velocities declined from a peak of 1.0 m/s (+/- 0.1 m/s). Helical flow patterns in the upper descending aorta varied between subjects, apparently depending on arch curvature. End-systolic retrograde flow originated from regions of blood with low momentum, usually along inner wall curvatures. Flow studies in a curved tubular phantom showed right-handed helical flow in the upper "arch" when the inflow section was positioned to simulate ascending aortic curvature, and retrograde flow occurred along the inner wall at end systole during pulsatile flow. CONCLUSIONS: Helical and retrograde streams are consistent features of intra-aortic flow in healthy subjects that result, at least in part, from the curvature of the arch and the pulsatility of flow in it. They may have significance in relation to circulatory dynamics and the pathogenesis of atheroma in the arch.

Adult↗

Magnetic resonance imaging during dobutamine stress in coronary artery disease.

Cine magnetic resonance imaging (MRI) provides a tomographic method of assessing regional ventricular function in any desired plane. It has not been possible to obtain adequate images during dynamic exercise, and this has limited its value in patients with coronary artery disease (CAD). Therefore, an infusion of dobutamine was used to study 25 patients with exertional chest pain and abnormal exercise electrocardiograms. Areas of abnormal wall motion were compared with areas of abnormal myocardial perfusion imaged by dobutamine thallium emission tomography and with coronary arteriography. Twenty-two patients had significant CAD. Twenty-one (96%) of these patients had reversible myocardial ischemia shown by dobutamine thallium tomography, and 20 (91%) had reversible wall motion abnormalities shown by dobutamine MRI. Comparison of abnormal segments of perfusion and wall motion showed 96% agreement at rest, 90% agreement during stress, and 91% agreement for the assessment of functional reversibility. The normalized magnetic resonance signal intensity of the ischemic segments showed a small but significant reduction when compared with that of normal segments (-67 units [9.2%]; p less than 0.05). Dobutamine infusion was well-tolerated, despite causing chest discomfort in 24 patients (96%). Nine patients (36%) developed a minor dysrhythmia that was usually ventricular premature complexes, but this did not limit infusion, and other side effects were mild. The short plasma half-life of dobutamine makes it ideal as a stress agent for imaging techniques (such as MRI), and these results suggest that it is more effective in the provocation of wall motion abnormalities than is dipyridamole in patients with CAD.

Adult↗

Obstruction in extracardiac ventriculopulmonary conduits: value of nuclear magnetic resonance imaging with velocity mapping and Doppler echocardiography.

OBJECTIVES: This study was designed to investigate the value of noninvasive imaging modalities for the detection of obstruction in extracardiac ventriculopulmonary conduits. BACKGROUND: the diagnosis of obstruction in a conduit by noninvasive methods can be difficult. Obstruction may be silent and its progression unnoticed. Nuclear magnetic resonance imaging (NMR) with velocity mapping is a new noninvasive technique that can provide high resolution images and has been shown to be a reliable method of measuring blood flow velocity. METHODS: Two-dimensional echocardiography, pulsed wave Doppler echocardiography and NMR spin echo imaging were used in 52 patients with an extracardiac ventriculopulmonary conduit. Continuous wave Doppler echocardiography was used in 30 of these, Doppler color flow mapping in 26 and NMR velocity mapping in 12. Cardiac catheterization data were available in 27 patients and operative or autopsy findings in 11. RESULTS: The conduit could be assessed by two-dimensional and pulsed wave Doppler echocardiography in only 17% of patients. Doppler color flow and continuous wave echocardiography provided technically satisfactory data in 19% and 83%, respectively. The anatomy of the conduit was adequately displayed by NMR imaging in 90%. A minimal diameter less than 18 mm indicated conduit obstruction, although failure to detect calcification resulted in obstruction being missed in some patients. Calculated gradients in obstructed conduits derived from NMR velocity mapping correlated well with results of continuous wave Doppler echocardiography and gave an accurate localization of the site of obstruction as well as a measure of its severity. CONCLUSION: NMR imaging with velocity mapping is the most effective noninvasive method of assessing obstruction in ventriculopulmonary conduits and can obviate the need for invasive investigation before an interventional procedure is performed.

Adult↗

Magnetic resonance morphological, chemical shift and flow imaging in peripheral vascular disease.

We have used magnetic resonance imaging to study the aorto-iliac region in 13 patients with peripheral disease. Five healthy volunteers were studied for comparison. Magnetic resonance spin-echo imaging, chemical shift imaging to determine lipid content of atheroma, phase-shift velocity mapping and quantitative flow studies were obtained and the findings compared with radiological angiograms. The velocity profiles study showed an increased velocity at the site of a stenosis in eight patients who had iliac artery disease. Quantitative flow measurements made in both iliac arteries and the aorta in five patients and five volunteers showed a flow ratio in both iliac arteries less than 0.85 in patients with a stenosis of one iliac artery and a ratio greater than 0.85 in the volunteers. In one patient studied before and after angioplasty, flow improved post-angioplasty. The flow curve showed a characteristic distortion in diseased vessels compared with healthy vessels. In the chemical shift images of aortic atheroma five were classified as fibrous and three were lipid rich. This preliminary study showed the potential of magnetic resonance to assess non-invasively the morphology, composition and the haemodynamic significance of atheroma. This could be important in the study of the progression of peripheral vascular disease and its response to pharmacological and surgical intervention and in the planning treatment of lesions.

Adult↗

Valve and great vessel stenosis: assessment with MR jet velocity mapping.

For measurement of poststenotic jet velocities with magnetic resonance (MR) imaging, the authors reduced the echo time (TE) of the field even-echo rephasing (FEER) velocity mapping sequence from 14.0 to 3.6 msec, so minimizing the problem of MR signal loss from turbulent fluid. In vitro use of rotating disk and stenotic flow phantoms confirmed that the 3.6-msec TE sequence enables accurate measurement of jet velocities of up to 6.0 m/sec (r = .996). Peak jet velocity measurements were made with MR imaging in 36 patients with stenosis of native heart valves (n = 9), conduits (n = 19), or Fontan connections (n = 2) or with aortic coarctation (n = 6). Peak velocity measurements made with MR imaging agreed well with measurements made with Doppler ultrasound (US), which were available in 18 cases (standard deviation = 0.2 m/sec). Velocity mapping with fast-echo MR imaging is likely to have considerable importance as a noninvasive means of locating and evaluating stenoses, particularly at sites inaccessible to US, but care must be taken to prevent errors caused by malalignment, signal loss, phase wrap, or partial-volume effects.

Adult↗