Model studies of the magnetocardiogram.

A general expression is developed for the quasi-static magnetic field outside an inhomogeneous nonmagnetic volume conductor containing internal electromotive forces. Multipole expansions for both the electric and magnetic fields are derived. It is shown that the external magnetic field vanishes under conditions of axial symmetry. The magnetic field for a dipole current source in a sphere is derived, and the effect of an eccentric spherical inhomogeneity is analyzed. Finally the magnetic dipole moment is calculated for a current dipole in a conducting prolate spheroid.

Conductometry↗

Mean flow velocity patterns within a ventricular assist device.

A laser Doppler anemometry system was used to measure fluid velocities at 127 locations within a plexiglas model of the 70 cm3 Penn State electric ventricular assist device (VAD) fitted with Bjork-Shiley convexo-concave tilting disk valves. The velocity measurements were made using a seeded blood analog fluid that matched the kinematic viscosity of blood and the refractive index of plexiglas. At each location, 250 instantaneous velocity realizations were collected at eight instances during the pump cycle. The data were filtered and averaged to calculate mean (ensemble averaged) velocities. The results indicate that the largest mean velocities are created during systole in the VADs outlet tract, and during diastole in the major orifice of the mitral valve. A single vortex centered roughly about the axis of the cylindrical portion of the pump is created during early diastole. This vortex, which persists into early systole, provides good washing of the VAD walls. However, it does appear to impede the flow entering the VAD through the minor orifice of the mitral valve. High velocities also occur during diastole along the minor orifice wall of the outlet tract and are directed into the chamber. These retrograde velocities suggest the presence of a regurgitant jet near the wall of the prosthetic valve.

Blood Flow Velocity↗

In vivo observation of cavitation on prosthetic heart valves.

In this study, a method to determine the existence of prosthetic heart valve cavitation in vivo is presented. Pennsylvania State University Left Ventricular Assist Devices (LVADs) were implanted in two separate calves for this study. Björk-Shiley Monostrut (Irvine, CA) 27 mm and 25 mm valves with Delrin occluders were used in the mitral and aortic positions, respectively. A high fidelity, piezoelectric pressure transducer was mounted approximately 1.25 cm proximal to the mitral valve and measured the high frequency pressure fluctuations caused by cavitation bubble formation and collapse after valve closure. The root mean square (RMS) value of the mitral pressure signal during a 5 ms interval after valve closure was used as a measure of cavitation intensity. The pressure signals observed in vivo were similar to ones observed in vitro with the same type of pressure transducer and were associated with the visually observed cavitation. The percentage of beats with cavitation increased from 20.3% to 67.7% when pump filling was decreased by increasing beat rate. A blood test conducted during post-operative days 1-3 showed a significant increase in plasma hemoglobin during the low filling condition. However, blood tests conducted later (post-operative days 7-44) did not show a significant change in plasma hemoglobin during low filling conditions.

Animals↗

The zero of potential.

It is convenient to select a reference point for recording ECG potentials on the torso or EEG potentials on the scalp. The body is a bounded, insulated volume conductor. As such, it is meaningless to seek a point whose potential is at true zero. The choice of a particular reference, and hence the amplitude assigned to a contour, does not change in any way the biophysical information contained in the potential distribution. It does not in any way change the relation between source and potential, except for an additive constant of no physical significance. Standardization of a reference is useful for comparing, more directly, data from different laboratories. An agreed upon reference is necessary when a limited number of leads are used for diagnosis. In the case of the electrocardiogram, the generally agreed upon reference is the WCT. The issue of the zero of potential seems to arouse passions that may sometimes inhibit scientific discourse.

Action Potentials↗