Search PubMed⌕ Search

Biomedical subjects

D Assif

Publications and source records attributed to D Assif.

39 records · Page 3Linked to original sources

Accuracy of implant impression splinted techniques: effect of splinting material.

Three implant impression techniques, using 3 different splinting materials, were assessed for accuracy in a laboratory model that simulated clinical practice. For group A, an autopolymerizing acrylic resin was used to splint transfer copings. In group B, a dual-cure acrylic resin was used, and for group C, plaster, which was also the impression material, was used. A metal implant master cast with an implant master framework was made to accurately fit to the cast. This cast was the standard for all impressions. For each group, 15 impressions were made. Polyether impression material was used for groups A and B. The accuracy of the stone casts with the implant analogues was measured against the master framework, using strain gauges. A multiple analysis of variance with repeated measures was performed to test for significant differences among the 3 groups. Additional analyses of variance were carried out to locate the source of difference. The statistical analyses revealed that a significant difference existed between groups A and B and between groups B and C but not between groups A and C. Impression techniques using autopolymerizing acrylic resin or impression plaster as a splinting material were significantly more accurate than dual-cure acrylic resin. Plaster is the material of choice in completely edentulous patients, since it is much easier to manipulate, less time consuming, and less expensive.

Acrylic Resins↗

Accuracy of implant impression techniques.

Three impression techniques were assessed for accuracy in a laboratory cast that simulated clinical practice. The first technique used autopolymerizing acrylic resin to splint the transfer copings. The second involved splinting of the transfer copings directly to an acrylic resin custom tray. In the third, only impression material was used to orient the transfer copings. The accuracy of stone casts with implant analogs was measured against a master framework. The fit of the framework on the casts was tested using strain gauges. The technique using acrylic resin to splint transfer copings in the impression material was significantly more accurate than the two other techniques. Stresses observed in the framework are described and discussed with suggestions to improve clinical and laboratory techniques.

Acrylic Resins↗