Search PubMed⌕ Search

Biomedical subjects

D A Saville

Publications and source records attributed to D A Saville.

14 recordsLinked to original sources

Orientational order of molecular assemblies on inorganic crystals.

Surfactant micelles form oriented arrays on crystalline substrates although registration is unexpected since the template unit cell is small compared to the size of a rodlike micelle. Interaction energy calculations based on molecular simulations reveal that orientational energy differences on a molecular scale are too small to explain matters. With atomic force microscopy, we show that orientational ordering is a dynamic, multimolecule process. Treating the cooperative processes as a balance between van der Waals torque on a large, rodlike micellar assembly and Brownian motion shows that orientation is favored.

Journal Article↗

Comment on "A broad frequency range dielectric spectrometer for colloidal suspensions: cell design, calibration, and validation".

Recently, a simple analytical model was derived from the standard electrokinetic theory to deal with electrode polarization in low frequency dielectric measurements [Hollingsworth and Saville, J. Colloid Interface Sci. 257 (2003) 65-76]. Comparisons were made between dielectric constant-frequency relationships extracted from data on electrolyte solutions using the analytical model and the well-known RC-circuit analog. Electrolyte spectra interpreted with the analytical approach remained smooth (and constant) down to much lower frequencies than was the case with the RC model. It was also shown how the RC model arises naturally from the analytical model as an asymptotic expansion in inverse powers of the electrode spacing. Numerical calculations indicated substantial differences between the two models at low frequencies due to higher order terms omitted in the RC model. As it turns out, the comparison contained a numerical error. Here we revisit the methodology to show that although the two formulations disagree, they do so (in a numerical sense) only at much smaller electrode separations than those used in the aforementioned example. The purpose of this Letter is to correct the numerical error and show, explicitly, how the RC-circuit analog coefficients are related to the asymptotic expansion at low frequencies.

Letter↗

Dielectric spectroscopy and electrophoretic mobility measurements interpreted with the standard electrokinetic model.

We report results from complementary electrokinetic measurements-dielectric relaxation and electrophoretic mobility-undertaken to test the applicability of the standard electrokinetic theory with a model system. Dielectric spectra were obtained at frequencies between 1 kHz and 40 MHz with a new, two-electrode cell design [Hollingsworth and Saville, J. Colloid Interface Sci. 257 (2003) 65-76]; mobility data were acquired with an electrophoretic light scattering instrument. Data from the two-electrode cell were collected at different electrode separations and interpreted with newly developed procedures to remove the influence of electrode polarization. Methodology A employs extrapolation to infinite electrode separation to compute the dielectric constant and conductivity as functions of frequency. The contributions from suspended particles are reported in terms of dielectric constant and conductivity increments. Methodology B uses a theoretical model of electrode polarization and the standard electrokinetic model in a nonlinear regression scheme. Results are presented in several forms: frequency-dependent dielectric constant and conductivity increments, frequency-dependent dielectric constants and conductivities, and the complex dipole coefficient. It is shown that the standard model provides a consistent methodology for interpreting particle behavior; zeta-potentials inferred from mobility and dielectric relaxation agree to within experimental error. Moreover, the cell design and interpretation are straightforward and provide relatively simple ways to obtain complementary measurements over a wide frequency range. The results unambiguously show that electrokinetic character of this dispersion follows the standard model.

Journal Article↗

Assembly of colloidal aggregates by electrohydrodynamic flow: Kinetic experiments and scaling analysis.

Electric fields generate transverse flows near electrodes that sweep colloidal particles into densely packed assemblies. We interpret this behavior in terms of electrohydrodynamic motion stemming from distortions of the field by the particles that alter the body force distribution in the electrode charge polarization layer. A scaling analysis shows how the action of the applied electric field generates fluid motion that carries particles toward one another. The resulting fluid velocity is proportional to the square of the applied field and decreases inversely with frequency. Experimental measurements of the particle aggregation rate accord with the electrohydrodynamic theory over a wide range of voltages and frequencies.

Journal Article↗

Polarizability and complex conductivity of dilute suspensions of spherical colloidal particles with uncharged (neutral) polymer coatings.

The polarizability of polymer-coated colloidal particles, as measured via dielectric relaxation spectroscopy, reflects on the degree to which convection, diffusion, and electromigration deform the equilibrium double layer. With a polymer coating, convection and electro-osmosis are resisted by hydrodynamic drag on the polymer segments. The electro-osmotic flow near the underlying bare surface is therefore diminished. Characteristics of the particles and the adsorbed polymer can, in principle, be inferred by measuring the frequency-dependent polarizability. In this work, "exact" numerical solutions of the electrokinetic equations are used to examine how adsorbed polymer changes the particle polarizability and, hence, the conductivity and dielectric constant increments of dilute suspensions. For neutral polymer coatings, the conductivity and dielectric constant increments are found to be very similar to those of the underlying bare particles, so the response depends mostly on the underlying bare particles. These observations suggest that dielectric spectroscopy is best used to determine the underlying surface charge, with characteristics of the coating inferred from the electrophoretic or dynamic mobility, together with the hydrodynamic radius obtained from sedimentation or dynamic light scattering. Addressed briefly are the effects of added counterions and nonspecific adsorption. The electrokinetic model explored in this work can be used to guide experiments (frequency and ionic strength, for example) to either minimize or maximize the sensitivity of the complex conductivity to the coating thickness or permeability.

Journal Article↗

Polarizability and complex conductivity of dilute suspensions of spherical colloidal particles with charged (polyelectrolyte) coatings.

The dielectric relaxation of polyelectrolyte-coated colloidal particles is examined via "exact" numerical solutions of the governing electrokinetic equations. The charged polymer coatings are characterized by a nominal charge density, thickness, and permeability. Brush-like segment density profiles are considered here, but more sophisticated segment and charge density profiles are accommodated by the model. The role of added counterions and nonspecific adsorption is considered briefly before examining how the experimentally measured conductivity and dielectric constant increments reflect the frequency of the applied electric field, the strength of the electrolyte, and characteristics of the polymer coatings, namely the charge, charge density, and permeability. Finally, a strategy is suggested by which dielectric spectroscopy and electrophoresis can be used to characterize polymer-coated particles. This approach complements experiments where electroviscous effects such as dynamic light scattering and sedimentation are weak.

Journal Article↗

Electrically guided assembly of planar superlattices in binary colloidal suspensions.

Binary colloidal suspensions are assembled into planar superlattices using ac electric fields. Either triangular or square-packed arrays form, depending on the frequency and relative particle concentrations. The frequency dependence is striking since superlattices develop at low and high frequencies but not at intermediate frequencies. We explain the low frequency behavior (<3 kHz) in terms of induced-dipole repulsion balanced by attraction resulting from electrohydrodynamic (EHD) flow. At high frequencies (20-200 kHz), EHD flow is negligible but aggregation occurs since dipole-dipole interactions become attractive.

Journal Article↗

A broad frequency range dielectric spectrometer for colloidal suspensions: cell design, calibration, and validation.

Electrode polarization complicates low-frequency measurements of the dielectric response of electrolyte solutions and colloidal suspensions. To deal with this longstanding problem, a new dielectric cell was developed along with a model based on the standard electrokinetic theory. The parallel plate cell utilizes a thin chamber that is easily filled and emptied; different chamber thicknesses are readily accommodated. The analytical form of the theoretical impedance model makes data analysis straightforward. Using standard electrolytes, the device and the theoretical model were tested over a wide range of frequencies for several electrolyte concentrations. Excellent agreement was found between the theory and the experimental data. The methodology developed to account for polarization effects exhibits a significant improvement over the conventional approaches and points up a deficiency in often-used equivalent circuit models.

Journal Article↗

The effects of electroosmosis on the structure of isotachophoresis boundaries.

The influence of convection on the structure of an isotachophoretic boundary is investigated using an asymptotic method to simplify the conservation equations. To illustrate the methodology it is applied to a simple strong electrolyte system consisting of three ions and the relevant equations solved numerically. The technique, however, is of general applicability and can be useful in exploring the influence of various flow processes on analytical and preparative electrophoretic separation techniques in addition to isotachophoresis.

Diffusion↗

Computer simulation and experimental validation of the electrophoretic behavior of proteins.

A mathematical model of the electrophoretic behavior of proteins is presented. The Debye-Hückel-Henry theory is used for the description of protein mobility, which has the important result of making net mobility a function of ionic strength. A net charge vs pH relationship and a diffusion coefficient are required to describe a specific protein. The model is employed for the computer simulation of three distinct electrophoretic modes: isoelectric focusing, isotachophoresis, and zone electrophoresis. The validity of the model is tested by comparing simulation with experimental data. Excellent qualitative agreement was found.

Computer Simulation↗

Electrophoresis: mathematical modeling and computer simulation.

A mathematical model of electrophoretic separation processes has been developed and adapted for computer simulations. The model is used to predict the characteristic behavior of a variety of electrophoretic techniques from a knowledge of chemical equilibria and physical transport phenomena. The model provides a unifying basis for a rational classification of all electrophoretic processes.

Computers↗

Mathematical modeling and computer simulation of isoelectric focusing with electrochemically defined ampholytes.

A mathematical model of isoelectric focusing at the steady state has been developed for an M-component system of electrochemically defined ampholytes. The model is formulated from fundamental principles describing the components' chemical equilibria, mass transfer resulting from diffusion and electromigration, and electroneutrality. The model consists of ordinary differential equations coupled with a system of algebraic equations. The model is implemented on a digital computer using FORTRAN-based simulation software. Computer simulation data are presented for several two-component systems showing the effects of varying the isoelectric points and dissociation constants of the constituents.

Journal Article↗

Mathematical model for transient isoelectric focusing of simple ampholytes.

A mathematical model describing transient processes in isoelectric focusing (IEF) of L biprotic ampholytes is presented. The model is a generalization of our previous research on steady slate in IEF and consists of L nonlinear partial differential equations coupled with 2L+2 algebraic equations. Constraints imposed by the mode of operation, viz., constant current. voltage or power, are described. Due to the nonlinearity of the equations, analysis of the model requires computer simulation. Model equations suitable for computer implementation are derived.

Journal Article↗