Search PubMed⌕ Search

Biomedical subjects

D A Roberts

Publications and source records attributed to D A Roberts.

At least 19 recordsLinked to original sources

Direct measurement of the L/K ratio in (7)Be electron capture.

The ratio of L- to K-shell electron captures in light nuclei is particularly sensitive to electron overlap and exchange effects. Calculations of these effects in (7)Be disagree by more than 20%. We report a measurement of the L/K ratio in (7)Be, using a cryogenic microcalorimeter which clearly separates L- and K-shell captures. The obtained L/K ratio of 0.040(6) is less than half that of existing predictions for free (7)Be. The discrepancy is likely due to in-medium effects distorting the L-shell electron orbitals.

Journal Article↗

Dynamic observation of pulmonary perfusion using continuous arterial spin-labeling in a pig model.

The continuous arterial spin-labeling (CASL) method of perfusion MRI is used to observe pulmonary perfusion dynamically in an animal model. Specifically, a respiratory-triggered implementation of the CASL method is used with approximate spatial resolution of 0.9 x 1.8 x 5.0 mm (0.008 cc) and 2-minute temporal resolution. Perfusion MRI is performed dynamically during repeated balloon occlusion of a segmental pulmonary artery, as well as during pharmacological stimulation. A total of three Yorkshire pigs were studied. The results demonstrate the ability of the endogenous spin-labeling method to characterize the dynamic changes in pulmonary perfusion that occur during important physiological alterations.

Animals↗

Upper gastrointestinal hemorrhage and transcatheter embolotherapy: clinical and technical factors impacting success and survival.

PURPOSE: To identify clinical and technical factors influencing the outcome of transcatheter embolotherapy for nonvariceal upper gastrointestinal (GI) hemorrhage and to quantify the impact of successful intervention on patient survival. MATERIALS AND METHODS: A retrospective review was performed of all patients (n = 163) who underwent arterial embolization for acute upper GI hemorrhage at a university hospital over an 11.5-year period. Clinical success was defined as target area devascularization that resulted in the clinical cessation of bleeding and stabilization of hemoglobin level. The clinical condition of each patient at intervention was defined by history, laboratory examination, and two composite indicator variables. With use of logistic regression, the dependent variable, clinical success, was modeled on two categories of clinical and technical variables. A final model regressed patient survival on clinical success and other clinical variables. RESULTS: None of the procedural variables analyzed had a significant influence on clinical success. Several clinical variables did impact clinical success, including multiorgan system failure (OR, 0.36; P =.030), coagulopathy (OR, 0.36; P =.026), and bleeding subsequent to trauma (OR, 7.1; P =.040) or invasive procedures (OR, 6.5; P =.009). Regardless of their clinical condition at intervention, patients who underwent clinically successful embolization were 13.3 times more likely to survive than those who had an unsuccessful procedure (CI, 4.54-39.2; P =.000). Nevertheless, patients with multiorgan system failure were 17.5 times more likely to die, independent of the outcome of the procedure (CI, 0.014-0.229; P =.000). CONCLUSION: Arresting nonvariceal upper GI hemorrhage with transcatheter embolotherapy has a large positive effect on patient survival, independent of clinical condition or demonstrable extravasation at intervention. Aggressive treatment with transcatheter embolotherapy is advisable in patients with acute nonvariceal upper GI hemorrhage.

Adult↗

Magnetic resonance imaging of thoracic aortic aneurysm and dissection.

MRI is an extremely useful technique for the evaluation of the thoracic aorta. It provides a comprehensive evaluation of all the important structures within the chest and allows for high-resolution imaging of both the aortic lumen and the wall itself. As such, it is a sensitive method for delineating the extent of disease, branch-vessel involvement, and superimposed complications. Technical advances, such as stepped-table MRA and bolus-timing strategies, continue to improve overall image quality. In addition, the recent development of blood-pool contrast agents may further impact the diagnostic yield. Given these facts, MRI is likely to remain a mainstay in this patient population for years to come.

Aortic Dissection↗

An apparatus for applying strong longitudinal magnetic fields to clinical photon and electron beams.

Monte Carlo studies have recently renewed interest in the use of the effect of strong transverse and longitudinal magnetic fields to manipulate the dose characteristics of clinical photon and electron beams. A 3.5 T superconducting solenoidal magnet was used to evaluate the effect of a longitudinal field on both photon and electron beams. This note describes the apparatus and demonstrates some of the effects on the beam trajectory and dose distributions for measurements in a homogeneous phantom. The effects were studied using film in air and in phantoms which fit in the magnet bore. The magnetic field focused and collimated the electron beams. The converging, non-uniform field confined the beam and caused it to converge with increasing depth in the phantom. Due to the field's collecting and focusing effect, the beam flux density increased, leading to increased dose deposition near the magnetic axis, especially near the surface of the phantom. This study illustrates some benefits and challenges associated with the use of non-uniform longitudinal magnetic fields in conjunction with clinical electron and photon beams.

Electrons↗

Pulmonary arteriovenous malformations: three-dimensional gadolinium-enhanced MR angiography-initial experience.

PURPOSE: To determine whether three-dimensional gadolinium-enhanced magnetic resonance (MR) angiography could be used to identify pulmonary arteriovenous malformations (PAVMs) and to accurately identify the size and number of feeding arteries. MATERIALS AND METHODS: Eight patients suspected of having PAVM were examined with three-dimensional MR angiography at 1.5 T. Images were reviewed by a single radiologist blinded to conventional angiographic findings who evaluated each image for the size, number, and location of PAVMs, as well as for the size and number of feeding arteries. Five patients underwent conventional angiography with embolization therapy, and one patient underwent lobectomy. Two patients did not undergo either surgery or angiography. RESULTS: Three-dimensional MR angiography revealed nine (90%) of 10 PAVMs that were confirmed at conventional angiography (n = 9) or examination of a surgical specimen (n = 1). The single PAVM that was not identified prospectively at MR angiography was small (3-4 mm) and peripheral. Two additional PAVMs were identified in the two patients who did not undergo surgery or angiography. CONCLUSION: Three-dimensional MR angiography is a promising technique for use in the diagnosis of PAVM, although small (<5-mm) PAVMs may be more difficult to identify with the technique. The technique is a particularly useful means of noninvasively demonstrating the size and number of feeding arteries prior to treatment.

Adolescent↗

Demonstration of a compact compressor for application of metastability-exchange optical pumping of 3He to human lung imaging.

Hyperpolarized gas magnetic resonance imaging has recently emerged as a method to image lungs, sinuses, and the brain. The best lung images to date have been produced using hyperpolarized 3He, which is produced by either spin-exchange or metastability-exchange optical pumping. For hyperpolarized gas MRI, the metastable method has demonstrated higher polarization levels and higher polarizing rates, but it requires compression of the hyperpolarized gas. Prior to this work, compression of hyperpolarized gas had only been accomplished using a large, complex and expensive apparatus. Here, human lung ventilation images are presented that were obtained using a compact compressor that is relatively simple and inexpensive. For this test, 1.1 bar-L of 15% hyperpolarized 3He gas was produced at the National Institute of Standards and Technology using a modified commercial diaphragm pump. The hyperpolarized gas was transported to the University of Pennsylvania in a holding field provided by a portable solenoid.

Adult↗

Detection and localization of pulmonary air leaks using laser-polarized (3)He MRI.

Pulmonary air leaks were created in the lungs of Yorkshire pigs. Dynamic, 3D MRI of laser-polarized (3)He gas was then performed using a gradient-echo pulse sequence. Coronal magnitude images of the helium distribution were acquired during gas inhalation with a voxel resolution of approximately 1.2 x 2.5 x 8 mm, and a time resolution of 5 sec. In each animal, the ventilation images reveal focal high-signal intensity within the pleural cavity at the site of the air leaks. In addition, a wedge-shaped region of increased parenchymal signal intensity was observed adjacent to the site of the air leak in one animal. (3)He MRI may prove helpful in the management of patients with pulmonary air leaks.

Administration, Inhalation↗

Magnetization transfer imaging of the brain: A quantitative comparison of results obtained at 1.5 and 4.0 T.

The preliminary results of magnetization transfer (MT) imaging on a whole body 4.0 T system are presented. Cooked egg phantoms and several volunteers were imaged on 1.5 and 4.0 T magnets interfaced to GE Signa scanners. The MT ratio (MTR), signal difference to noise ratio (SDNR), and contrast parameters were measured at both fields and compared. Furthermore, single-shot Z-spectroscopy was used to characterize the frequency dependence of the MT phenomenon. The results show that MT imaging can be safely performed at 4.0 T without exceeding limitations of radio frequency power. The MT effect is more pronounced at the higher field, leading to better quality images with higher contrast and SDNR. The Z-spectra are not markedly different at the higher field although the MTR is greater. The potential applications of this technique to study neurodegenerative diseases, as well as, perfusion imaging and angiography are discussed. J. Magn. Reson. Imaging 1999;10:527-532.

Brain↗

On-line monitoring of radiotherapy beams: experimental results with proton beams.

Proton radiotherapy is a powerful tool in the local control of cancer. The advantages of proton radiotherapy over gamma-ray therapy arise from the phenomenon known as the Bragg peak. This phenomenon enables large doses to be delivered to well-defined volumes while sparing surrounding healthy tissue. To fully realize the potential of this technique the location of the high-dose volume must be controlled very accurately. An imaging system was designed and tested to monitor the positron-emitting activity created by the beam as a means of verifying the beam's range, monitoring dose, and determining tissue composition. The prototype imaging system consists of 12 pairs of cylindrical BGO detectors shielded in lead. Each crystal was 1.9 cm in diameter, 5.0 cm long, and separated by 0.5 cm from other detectors in the row. These are arranged in two rows, 60 cm apart, with the proton beam and tissue phantoms half-way between and parallel to the detector rows. Experiments were conducted with 150 MeV continuous and macro-pulsed proton beams which had beam currents ranging from 0.14 nA to 1.75 nA. The production and decay of short-lived isotopes, 15O and 14O, was studied using 1 min irradiations with a continuous beam. These isotopes provide a significant signal on short time scales, making on-line imaging possible. Macro-pulsed beams, having a period of 10 s, were used to study on-line imaging and the production and decay of long-lived isotopes, 13N, 11C, and 18F. Decay data were acquired and on-line images were obtained between beam pulses and indicate that range verification is possible, for a 150 MeV beam, after one beam pulse, to within the 1.2 cm resolution limit of the imaging system. The dose delivered to the patient may also be monitored by observing the increase in the number of coincidence events detected between successive beam pulses. Over 80% of the initial positron-emitting activity is from 15O while the remainder is primarily 11C, 13N, 14O with traces of 18F, and 10C. Radioisotopic imaging may also be performed along the beam path by fitting decay data collected after the treatment is complete. Using this technique, it is shown that variations in elemental composition in inhomogenous treatment volumes may be identified and used to locate anatomic landmarks. Radioisotopic imaging also reveals that 14O is created well beyond the Bragg peak, apparently by secondary neutrons.

Biophysical Phenomena↗

Pulmonary perfusion: respiratory-triggered three-dimensional MR imaging with arterial spin tagging--preliminary results in healthy volunteers.

The authors used a spin-tagging method of magnetic resonance perfusion imaging to measure pulmonary perfusion in eight healthy volunteers with use of a respiratory-triggered three-dimensional pulse sequence. The average signal intensity (SI) decrease upon arterial labeling was 24%. The perfusion SI increased by 21% after exercise (P = .02). Focal blood flow abnormalities were observed in a patient with chronic obstructive pulmonary disease.

Adult↗

Quantitative anatomy of the occiput and the biomechanics of occipital screw fixation.

STUDY DESIGN: The surgically relevant osseous anatomy of the human anatomy was carefully studied and described. The stability of cortical and cancellous screws placed in anatomic sites commonly used for internal fixation of the occiput was tested. OBJECTIVES: To define the bony anatomy of the occiput in quantitative terms and to measure the ability of cortical and cancellous screws inserted at sites commonly used for internal fixation. SUMMARY OF BACKGROUND DATA: To the authors' knowledge, no previous studies described the gross anatomy of the occiput in specific relation to the internal venous structures in the cranium and to the biomechanical strength of screw fixation in different areas of the occiput. METHODS: Thirty-seven human occiputs were carefully measured using calipers. Thin sections from six such specimens were analyzed with specific attention to cortical thicknesses. Stability of screws placed in various locations in the occiput were tested in axial pullout. RESULTS: The thickness of the occiput varied from extremely thin to a 0.1-mm thickness in the region of the cerebellar fossa and increased to a maximum of 8.3 mm at the level of the superior nuchal line and at the transverse sulcus. Results of pullout testing showed that the cancellous screws were as strong as the cortical screws in this area. In areas of the occiput thicker than 7 mm, unicortical fixation was as strong as bicortical fixation. CONCLUSION: There is a wide variation in thickness of the bone of the occiput. The strength of screw fixation was proportional to the bone's thickness.

Biomechanical Phenomena↗

Perfusion imaging with compensation for asymmetric magnetization transfer effects.

The effects of off-resonance radio-frequency irradiation on the intensity of the MR signal from water protons in the cat brain are asymmetric around the chemical shift of the water signal. This asymmetry, which could arise from a shift in the magnetization transfer spectrum approximately 1.5 ppm upfield from the solvent water signal, must be taken into account to compensate for magnetization transfer effects inherent in arterial spin tagging approaches that use a single radio-frequency coil. Two approaches that either correct for, or circumvent, the apparent upfield shift of the magnetization transfer spectrum are presented, and a perfusion image of the cat brain, using flow-induced adiabatic inversion of arterial water protons, is presented. Other problems in obtaining quantitative cerebral blood flow values using the arterial spin tagging approach are discussed.

Animals↗

The relative abundance of dopamine D4 receptor mRNA in post mortem brains of schizophrenics and controls.

An increase in dopamine D4 receptors has recently been reported in post mortem brain samples from schizophrenics. We have attempted to complement this finding by assessing the levels of the specific messenger RNA (mRNA) for the D4 receptor, using the technique of quantitative RNA-PCR. No significant differences in the levels of expression of mRNA for the D4 receptor were found in the brains from schizophrenics compared to controls. The relationship between D4 receptors and schizophrenia, therefore, remains unclear.

Adult↗

Allelic variations in apolipoprotein E and prion protein genotype related to plaque formation and age of onset in sporadic Creutzfeldt-Jakob disease.

Prion gene sequence is thought to affect the phenotypic expression of prion disease and the E2 variant of apolipoprotein E (Apo E) can be neuroprotective in dementia. We determined codon 129 of the prion gene and the Apo E variants in Creutzfeldt-Jakob disease (CJD) using PCR and restriction digest. We found a significant correlation between valine at codon 129 of the prion protein gene and the presence of plaque in CJD and a later age of onset in CJD cases possessing the Apo E2 allele. This study provides further evidence that sequence variations in the prion gene can modify disease pathology and the neuroprotection afforded by Apo E2 is not confined to Alzheimer's disease.

Age of Onset↗

Development and intralaboratory evaluation of an in vitro human cell-based test to aid ocular irritancy assessments.

A human cell-based in vitro method was developed to screen for ocular irritancy potential of aqueous compatible and incompatible test agents, such as liquids, insoluble solids, powders, granulars, emulsions, and acids/alkalis. Methods were developed for topical application (an exposure that mimics in vivo testing) and wash-off of test substances on the epithelial surface of human skin derived epithelial-fibroblast cocultures (Skin2 Model ZK1200 from Advanced Tissue Sciences). These cultures contain noncornified stratified squamous epithelium, providing a three-dimensional in vitro model that resembles noncornified mucosal epithelium, such as cornea and conjunctiva. The hypothesis tested and confirmed in this work was that the rate of cytotoxicity induced by topical application of test substances to the stratified epithelial cell cultures would correlate with ocular irritancy. Test substances were applied to the cell system for up to 30 min, and cytotoxicity was measured as decreased 3-[4,5-dimethylthiazol-2-yl]2,5-diphenyltetrazolium bromide (MTT) vital dye metabolism. The time (in minutes) of exposure to test agent that reduced MTT metabolism to 50% of control levels (the t50 value) was calculated for each test substance, and these values showed a good correlation (r = 0.87) with historic rabbit low-volume eye test maximum average scores (MAS) for a range of liquid, solid, granular, powder, and other test materials, including consumer product formulations and ingredient chemicals. Additionally, t50 values confirmed the mild nature of selected cosmetic formulations. Taken together, these data indicate that this in vitro test, termed the tissue equivalent assay, is a valuable tool to screen for irritancy of test substances to mucosal tissues, such as cornea and conjunctiva.

Animal Testing Alternatives↗

Renal perfusion in humans: MR imaging with spin tagging of arterial water.

The authors tested a noninvasive technique for magnetic resonance imaging of perfusion in human kidneys. Magnetic labeling (spin tagging) of aortic arterial water was performed to generate an endogenous tracer. Breath-hold renal perfusion images obtained in seven volunteers yielded average perfusion rates in cortex and medulla of 278 mL.100 g-1.min-1 +/- 55 (standard error) and 55 mL.100 g-1.min-1 +/- 25, respectively.

Humans↗