Individualized eye shields for use in electron beam therapy as well as low-energy photon irradiation.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to D A Lightfoot.
Explore the source record for details and available documents.
A method is described for rapid and accurate computation of diagnostic x-ray spectra. Accuracy limitations of Kramers' equation are overcome by providing intensity correction factors derived from published measured data. Use of a parameter based on the energy of the Kramers spectrum intensity peak permits deriving master factor curves which are remarkably independent of kVp, waveform and filtration. Computed and measured spectra generally agree to better than +/- 1 keV for beams generated at 100 kVp and below. Possible application of the method to higher energy diagnostic beams is discussed.
A breast phantom of novel design has been used to measure visibility of simulated calcific and soft-tissue fibrillar details in mammography, as well as to determine the roentgen exposure vs. depth. Exposure data were combined with a model of the breast as compressed during mammography to compute the mean exposure to the ductal parenchyma (MDE). Three different imaging systems were compared over a wide range of x-ray beam energies and breast characteristics. "Dosage" criteria other than the MDE are discussed.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A new breast phantom has been designed for use in evaluating mammographic system performance. This phantom incorporates simulated calcifications and fibrillar objects in fat, of graded size, to permit measurements of detail visibility. A special methodology has been developed for measuring visible object size to achieve reproducible and clinically relevant results. Materials and construction of the phantom also permit carrying out dosimetry with an appropriate ionization chamber. Dosage and detail visibility measurements are reported for the Xerox 125, Min-R and Xonics systems. In addition to providing information regarding technique and image receptors, these results demonstrate the usefulness of the basic phantom design, and suggest possible improvements.
Much renewed interest has developed in electrostatic imaging systems. This is partly because of their use of relatively inexpensive materials and their potential for improved diagnostic accuracy--a novel combination of image latitude with great detail contrast. All such systems can exhibit these image characteristics when developed by the generally used "powder cloud" technique or some similar partial development system. We have measured edge sharpness and enhancement of electron radiographs (ERGs) produced with the powder cloud technique. Edge sharpness can be excellent at low image-density levels, but deteriorates with increasing density. Edge enhancement is also appreciable; it appears to decrease somewhat with increasing image density, but no simple relationship has yet been shown.
An ionization chamber method has been developed to measure exposure vs depth in a uniform BR 12 "average breast" phantom. It employs a Memorial mammography chamber for exit exposure measurements; resulting data is then corrected for backscatter as well as for the exceptionally thin window of this chamber. A careful comparison has then been made with relative exposure vs depth curves obtained using TLD at several mammography beam qualities, for identical exposure factors and SSD values. Use of a correction for residual and background TL signals significantly improved agreement between TLD and ion chamber curves in the 28 to 35 kVp/0.03 mm Mo range of beam quality. Agreement was within +/- 5% for the Mo target tube, but TLD readings were 4%--8% higher than ion chamber values for the W/Mo target tube. At Xeromammography energies (45 kVp/1.6 mm Al), corrected TLD curve readings were 6% higher at depth than ion chamber curve values. TLD meaurements with 28 to 35 kVp/0.03 mm Mo beams tend to underestimate dosage to the midbreast parenchyma. For example, in a 5 cm "average breast", the underestimation ranges from 2%--10% for corrected, 10%--16% for uncorrected TLD readings.