Search PubMed⌕ Search

Biomedical subjects

Csaba Horváth

Publications and source records attributed to Csaba Horváth.

At least 19 recordsLinked to original sources

Calcaneous quantitative ultrasound measurements predicts vertebral fractures in idiopathic male osteoporosis.

OBJECTIVES: The aim of this study was to identify the differences in ultrasound bone variables (QUS) and to test the ability to discriminate male patients with and without vertebral fractures. METHODS: We therefore measured broadband ultrasound attenuation (BUA) and speed of sound (SOS) matched for bone mineral density (BMD) and vertebral deformity in idiopathic male osteoporosis. RESULTS: One hundred and seventeen men (age 56.6 range 27-78) were divided into three groups (osteoporosis n=25, osteopenia n=58 and age-matched control n=34) according to BMD T-score by WHO criteria. We found 66 patients (56%) with at least one vertebral deformity during the study. BMD and BUA did not differ, while SOS was lower in osteoporosis (p<0.001) and control group (p<0.001) between the patients with and without vertebral compression. Strong positive correlation was demonstrated between BUA and BMD (lumbar spine r=0.44, p<0.001, femoral neck r=0.56, p<0.001, radius r=0.40, p<0.001), while similar association between SOS and BMD values was not shown. There was no relationship between the BUA and vertebral fracture risk (Odds ratio: 1.14 95% CI: 0.80-1.61). However, the relative risk of vertebral fracture by SOS was 1.56 (95% CI: 1.08-2.62). Adjusting for age and BMI the risk of vertebral fracture did not change (odds ratio for SOS 1.50 95% CI: 1.02-2.22). After adjustment for BMD SOS was still associated with fracture risk at all measured sites (odds ratio: 1.43, 95% CI: 1.02-2.22; 1.41, 95% CI: 1.02-2.17 and 1.32, 95% CI: 1.02-2.0). CONCLUSION: Our results suggest that BUA values are more closely related to density and structure while SOS values are able to predict fractures.

Absorptiometry, Photon↗

Comparative evaluation of local and international reference databases for forearm densitometry: different impacts on diagnostic decisions.

Reference databases play a key role in the management of osteoporosis. The aim of this preliminary study was to compare the diagnostic consequences of using either an international or a local reference database in peripheral densitometry. For this purpose, standard curves for bone mineral density (measured by dual-energy X-ray absorptiometry at the distal and proximal forearm) were generated for healthy Hungarian men and women. In total, 303 healthy volunteers of both sexes (age range: 20-94 yr) were recruited from four osteoporosis centers. Subjects with medical conditions or taking medication affecting the bone metabolism were excluded. Bone densitometry was performed with pDEXA (Norland-Stratec, Fort Atkinson, WI) devices in each center after cross-calibration of the machines. The precision error of the forearm measurement was also determined (<1% in vitro, and 1.2-2.5% in vivo). In females, the peak forearm density was detected in the 30-39-yr group. The density decreased by 8% per 5 yr in early postmenopausal females, and by 10% per 10 yr in late postmenopausal females. In males, the highest bone mineral density was found in the 30-39-yr group for the distal forearm, but 1 decade later for the proximal site. Subsequently, a 5% decrease in density occurred per 10 yr, except in the 8th decade, in which a 20% decrease was demonstrated. One thousand four hundred thirty-four patients with suspected osteoporosis were classified according to the forearm density T-scores using both the new Hungarian reference database and the international database provided by the manufacturer. Comparison of the results measured at the distal forearm with the two different databases led to similar outcomes. However, at the proximal site, one fifth of the female patients were reclassified from the low-density group to the normal group using the domestic normative database. An opposite difference was observed for the males: use of the Hungarian reference data resulted in 40% more men being categorized in the low-density group than when the international normal database was applied. Our results suggest that not only geographic differences, but also the reference database used, can influence the prevalence of the diagnosis of osteoporosis. Further data are currently being collected to increase the statistical power of the study.

Absorptiometry, Photon↗

Comparison of the femoral neck bone density, quantitative ultrasound and bone density of the heel between dominant and non-dominant side.

Our study was initiated to evaluate whether there are differences between the two sides, depending on hand dominance, in densitometry values and quantitative ultrasound parameters (QUS) of the lower limb. One hundred and six women and 44 men were involved. The hand dominance was determined by interview. The bone mineral density (BMD) of the left and the right femoral necks and the calcanei were measured by dual-energy X-ray absorptiometry (DXA). The QUS examination consisted of measuring the attenuation (BUA), the speed of the ultrasound (SOS) and quantitative ultrasound index (QUI) transversing the left and right calcanei. The density of the neck of femur of the non-dominant side did not differ from that of the dominant side. On the other hand, BMD, BUA and the QUI of the calcaneus were higher on the non-dominant side in both genders (p<0.05 for each parameter). No similar differences were seen for the SOS values. Our study has confirmed the side-to-side differences of the calcaneus in both genders, lower values were found on the dominant side. No similar differences were seen on the femur. The AUC values seemed to be higher on the dominant side, however, these differences were not strictly significant. In the case of peripheral site (heel) measurements, the practical significance of our observations is that they raise the possibility of performing peripheral DXA and QUS examinations of the calcaneus on the dominant side of the patient according to handedness.

Absorptiometry, Photon↗

[Effect of cigarette smoking on bone quality parameters in women].

INTRODUCTION: Smoking is a risk factor for osteoporosis. In a previous study, the authors showed lower bone density among smokers in a group of postmenopausal women. AIMS: After this finding, the primary goal of current research was to investigate how smoking could influence bone quality. METHODS: Forty-five (age range: 25-72 ys) smoker women were compared with 45 nonsmoker women adjusted for age and anthropometric parameters. Quantitative ultrasound method was used to determine the speed of ultrasound and the ultrasound attenuation transmitting the left heel (Achilles In Sight, GE Lunar). Dual photon absorptiometry method was applied to investigate the bone mineral density of lumbar spine and left femoral neck (Prodigy, GE Lunar) and single photon absorptiometry was used to determine the bone mineral content of radius at the non dominant side (NK-364, Gamma). RESULTS: No difference was found between smokers and non-smokers among the premenopausal group, however, postmenopausal smoker women had slightly lower speed of ultrasound and ultrasound attenuation values than non-smoker women. Postmenopausal smoker women suffering from bone fracture had significantly lower speed of ultrasound than postmenopausal non-smoker women (1508.9 vs. 1525.3 m/s, respectively), despite their bone density did not differ from each other. CONCLUSION: These data augment the knowledge about the injurious effect of smoking. The increased risk for bone fracture among smokers could be explained not only with the decrease of bone mass, which was previously described, but also with a decreased bone elasticity.

Absorptiometry, Photon↗

Bone disorders in experimentally induced liver disease in growing rats.

AIM: To investigate the change of bone parameters in a new model of experimentally induced liver cirrhosis and hepatocellular carcinoma (HCC) in growing rats. METHODS: Fischer-344 rats (n = 55) were used. Carbon tetrachloride (CCl(4)), phenobarbital (PB), and a single diethylnitrosamine (DEN) injection were used. Animals were killed at wk 8 and 16. Bone mineral content, femoral length, cortical index (quotient of cortical thickness and whole diameter) and ultimate bending load (F(max)) of the femora were determined. The results in animals treated with DEN+PB+CCl(4) (DPC, n = 21) were compared to those in untreated animals (UNT, n = 14) and in control group treated only with DEN+PB (DP, n = 20). RESULTS: Fatty liver and cirrhosis developed in each DPC-treated rat at wk 8 and HCC was presented at wk 16. No skeletal changes were found in this group at wk 8, but each parameter was lower (P<0.05 for each) at wk 16 in comparison to the control group. Neither fatty liver nor cirrhosis was observed in DP-treated animals at any time point. Femoral length and F(max) values were higher (P<0.05 for both) in DP-treated animals at wk 8 compared to the UNT controls. However, no difference was found at wk 16. CONCLUSION: Experimental liver cirrhosis and HCC are accompanied with inhibited skeletal growth, reduced bone mass, and decreased mechanical resistance in growing rats. Our results are in concordance with the data of other studies using different animal models. A novel finding is the transiently accelerated skeletal growth and bone strength after a 8-wk long phenobarbital treatment following diethylnitrosamine injection.

Animals↗

[Effects of body mass index on bone mineral density in men].

INTRODUCTION: A strong positive association between body mass index and bone mineral density is well defined in postmenopausal osteoporosis, but not in men. AIMS: The primary goal of the current research was to investigate this association in case of men. METHODS: According to WHO criteria (T-score below -1.0 at all measure site) seventy-two (mean age 55.7 +/- 0.99, range 38-78 yr normal density) healthy male with normal density were recruited. Exclusion criteria were the absence of any risk factors or signs of metabolic disease. Bone mineral measurements at the lumbar spine (L2-4) and femoral neck were performed by the dual-energy X-ray absorptiometry (DEXA, Lunar DPX-L, USA), bone mineral content of the non-dominant radius was measured with single photon absorptiometry (SPA, NK-364, Hungary). Participants were divided into three groups according to body mass index normal weight (18.5-24.9 kg/m2), moderate overweight (25-29.9 kg/m2) and obese subjects (> 30 kg/m2). RESULTS: Femur neck density was significantly lower in the normal weight than in the overweight counterparts (0.969 +/- 0.03 vs 1.062 +/- 0.02 p = 0.01). There was a strong positive association between BMI and femur neck BMD (r = 0.412 p < 0.001). Body mass was an independent predictor of femur neck bone mineral density (regression coefficients 0.382, p = 0.001). There was not correlation at the lumbar spine and the radius sites. CONCLUSION: Bone density at femur neck sites is lower in the normal weight men than in obese subjects, therefore the risk factors for proximal femur osteoporosis are higher in these cases. Prevention strategy is needed for men in the lowest quintile of body mass to prevent further decrease in BMD and reduce the risk of hip fracture.

Absorptiometry, Photon↗

Incorporation of single-wall carbon nanotubes into an organic polymer monolithic stationary phase for mu-HPLC and capillary electrochromatography.

Single-wall carbon nanotubes (SWNT) were incorporated into an organic polymer monolith containing vinylbenzyl chloride (VBC) and ethylene dimethacrylate (EDMA) to form a novel monolithic stationary phase for high-performance liquid chromatography (HPLC) and capillary electrochromatography (CEC). The retention behavior of neutral compounds on this poly(VBC-EDMA-SWNT) monolith was examined by separating a mixture of small organic molecules using micro-HPLC. The result indicated that incorporation of SWNT enhanced chromatographic retention of small neutral molecules in reversed-phase HPLC presumably because of their strongly hydrophobic characteristics. The stationary phase was formed inside a fused-silica capillary whose lumen was coated with covalently bound polyethyleneimine (PEI). The annular electroosmotic flow (EOF) generated by the PEI coating allowed peptide separation by CEC in the counterdirectional mode. Comparison of peptide separations on poly(VBC-EDMA-SWNT) and on poly(VBC-EDMA) with annular EOF generation revealed that the incorporation of SWNT into the monolithic stationary phase improved peak efficiency and influenced chromatographic retention. The structures of pretreated SWNT and poly(VBC-EDMA-SWNT) monolith were examined by high-resolution transmission electron microscopy, Raman spectroscopy, scanning electron microscopy, and multipoint BET nitrogen adsorption/desorption.

2-Propanol↗

Design and synthesis of a solid-phase fluorescent mass tag.

In this study, we demonstrate the design of a new solid-phase fluorescent mass tag (FMT) that contains the following features: (1) the FMT is synthesized using Fmoc chemistry which is simple, rapid, and cost-effective; (2) lysine is used as a uniformly labeled amino acid (using stable isotopes) to allow 8 Da difference between "heavy" and "light" tags; (3) a fluorescent molecule is coupled to the isotope tag that allows a tagged peptide to be detected by online fluorescence; and (4) an iodoacetyl reactive group provides cysteine reactivity. Using MALDI-TOF MS and HPLC, we show that the FMT reagent can be used to label standard cysteine-containing peptides as well as cysteine-containing peptides from a BSA tryptic digest.

Amino Acid Sequence↗

Serum leptin, soluble leptin receptor, free leptin index and bone mineral density in patients with primary biliary cirrhosis.

BACKGROUND/AIM: The pathophysiology of osteoporosis in chronic liver diseases is unknown. Recent data suggest that serum leptin is associated with bone mineral density (BMD). In animal studies leptin was found to be a potent inhibitor of bone formation. We investigated the relationship between serum leptin levels, soluble leptin receptor (sOB-R), free leptin index (FLI) and BMD in patients with primary biliary cirrhosis (PBC). PATIENTS AND METHODS: Ninety-four female patients with PBC were included in this study; 122 healthy women served as controls. Serum leptin levels were measured by radioimmunoassay, sOB-R by enzyme-linked immunosorbent assay. BMD was measured by dual energy X-ray absorptiometry in the lumbar spine and femoral neck. RESULTS: Serum leptin was significantly lower in patients with PBC compared with healthy controls. No difference was found between the body mass index (BMI) of patients and controls. There was a strong positive correlation between leptin and BMI. In PBC no association was found between leptin, sOB-R and liver function tests, histological stages or the presence of osteoporosis. Osteoporosis was present in 38 patients. A positive correlation was found between serum leptin and femoral neck z-score even after adjustment for BMI, whereas serum sOB-R correlated inversely with the serum leptin level. There was no difference in FLI between the subgroups of PBC patients according to the stages of the disease. CONCLUSIONS: We found a lower serum leptin level and a higher sOB-R in patients with PBC, which could not be explained by the difference in BMI. As leptin was associated with BMD, it may be hypothesized that leptin is involved in the complex regulation of bone metabolism in PBC.

Absorptiometry, Photon↗

Multistep mass tagging coupled with 2D LC-MS--an approach to increasing the number of identified proteins.

Identification of large numbers of proteins from complex biological samples is a continuing challenge in the area of quantitative proteomics. We introduce here a simple and reliable multistep mass tagging technique using our recently developed solid phase mass tagging reagents. When coupled with two-dimensional liquid chromatography/nano-electrospray ionization ion trap mass spectrometry (2D-LC/nano-ESI-MS), this method allows enhanced protein identification when tested on samples from prokaryotic and eukaryotic sources. The proteome of Escherichia coli D21 grown to either mid-exponential or stationary phase, and the membrane proteome from established breast cancer cell lines BT474 and MCF7 were used as model systems in these experiments. In both experiments, the numbers of total identified proteins are at least twice the numbers identified from a single tagging cycle. The sample complexity can be effectively reduced with corresponding increases in protein identification using the multistep method. The strategy described here represents a potentially powerful technique for large-scale qualitative and quantitative proteome research.

Cell Line, Tumor↗

The effect of intranasal salmon calcitonin therapy on bone mineral density in idiopathic male osteoporosis without vertebral fractures--an open label study.

The aim of this study was to examine the effect of intranasal salmon calcitonin therapy on bone mineral density (BMD) in idiopathic male osteoporosis without vertebral fractures. We conducted a randomized, open label, controlled trial in 71 male patients (mean age 59 +/- 6 years) suffering from idiopathic osteoporosis (femoral neck T-score < -2.5) without vertebral deformity. Patients in the control group (n = 31) received 400 IU Vitamin D + 1000 mg elemental calcium daily while the treatment group (n = 40) received 400 IU Vitamin D, 1000 mg elemental calcium plus 200 IU calcitonin nasal spray daily during alternate months. The study period was 18 months. Compared to controls, nasal calcitonin was associated with significant increases in bone mineral density at the lumbar spine (+3.5 +/- (-4.3%) vs. +0.83 +/- 6.4%, P = 0.04) and the femoral neck (+3.2 +/- 3.9% vs. +0.68 +/- 5.7%, P = 0.004). No significant difference was observed at the radius between the treatment groups (+1.4 +/- 8.8% vs. +1.4 +/- 10.9%, P = 0.98). Treatment was well tolerated with no premature discontinuations or significant side effects compared to the control group. We conclude that 200 IU salmon calcitonin nasal spray used daily, intermittently proved to be an effective and safe therapy in male idiopathic osteoporosis.

Administration, Intranasal↗

The role of liquid chromatography in proteomics.

Proteomics represents a significant challenge to separation scientists because of the diversity and complexity of proteins and peptides present in biological systems. Mass spectrometry as the central enabling technology in proteomics allows detection and identification of thousands of proteins and peptides in a single experiment. Liquid chromatography is recognized as an indispensable tool in proteomics research since it provides high-speed, high-resolution and high-sensitivity separation of macromolecules. In addition, the unique features of chromatography enable the detection of low-abundance species such as post-translationally modified proteins. Components such as phosphorylated proteins are often present in complex mixtures at vanishingly small concentrations. New chromatographic methods are needed to solve these analytical challenges, which are clearly formidable, but not insurmountable. This review covers recent advances in liquid chromatography, as it has impacted the area of proteomics. The future prospects for emerging chromatographic technologies such as monolithic capillary columns, high temperature chromatography and capillary electrochromatography are discussed.

Chromatography, Liquid↗

Capillary electrochromatography of peptides on a neutral porous monolith with annular electroosmotic flow generation.

A new kind of monolithic capillary column was prepared for capillary electrochromatography (CEC) with a positively charged polymer layer on the inner wall of a fused-silica capillary and a neutral monolithic packing as the bulk stationary phase. The fused-silica capillary was first silanized with 3-glycidoxypropyltrimethoxysilane (GPTMS). Polyethyleneimine (PEI) was then covalently bonded to the GPTMS coating to form an annular positively charged polymer layer for the generation of electroosmotic flow (EOF). A neutral bulk monolithic stationary phase was then prepared by in situ copolymerization of vinylbenzyl chloride (VBC) and ethylene glycol dimethacrylate in the presence of 1-propanol and formamide as porogens. Benzyl chloride functionalities on the monolith were subsequently hydrolyzed to benzyl alcohol groups. Effects of pH on the EOF mobility of the column were measured to monitor the completion of reactions. Using a column with this design, we expected general problems in CEC such as irreversible adsorption and electrostatic interaction between stationary phase and analytes to be reduced. A peptide mixture was successfully separated in counter-directional mode CEC. Comparison of peptide separations in isocratic monolithic CEC, gradient HPLC and capillary zone electrophoresis (CZE) indicated that the separation in CEC is governed by a dual mechanism that involves a complex interplay between selective chromatographic retention and differential electrophoretic migration.

Chromatography, High Pressure Liquid↗

Capillary electrochromatography of peptides and proteins.

This paper reviews recent progress in bioanalysis using capillary electrochromatography (CEC), especially in the field of separation of proteins and peptides. Fundamentals of CEC are briefly discussed. Since most of the recent developments on CEC have focused on column technology, i.e., design of new stationary phases and development of new column configurations, we describe here a variety of column architectures along with their advantages and disadvantages. Newly emerged column technologies in CEC for high speed and high efficiency separation are also discussed. Different analytical platforms of CEC such as pressure-assisted CEC or voltage-assisted micro- high-performance liquid chromatography (HPLC), CEC with different detection techniques, CEC on microchip platforms and multidimensional electrochromatography with their applications in peptide and protein analysis are presented.

Algorithms↗

Preparation and characterization of alkylated polymethacrylate monolithic columns for micro-HPLC of proteins.

Protein separations were carried out by micro-high performance liquid chromatography (micro-HPLC) with surface alkylated monolithic columns, which were prepared by in situ copolymerization of glycidyl methacrylate (GMA) and ethylene glycol dimethacrylate (EGDMA) in the presence of dodecanol and toluene as porogens. First, glycidyl groups at the surface of the porous monolith were hydrolyzed with sulfuric acid. The hydroxyl groups thus formed were then reacted with n-alkyl chloride to form alkylated stationary phase. Separation performance for proteins on columns with C18 and C8 stationary phases was compared. The results showed that a poly(GMA-EGDMA) support derivatized with octadecyl moieties could achieve much better resolution than one with octyl groups. A protein mixture was separated with the octadecylated poly-(GMA-EGDMA) monolithic column, and the effluent peaks were collected and analyzed by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS). The physical properties of the monolithic columns such as column morphology, surface area, mesopore size distribution, and column permeability were further characterized by scanning electron microscopy (SEM), multipoint BET nitrogen adsorption/desorption, and Darcy's law, respectively.

Adsorption↗

Elution-modified displacement chromatography coupled with electrospray ionization-MS: on-line detection of trace peptides at low-femtomole level in peptide digests.

Elution-modified displacement chromatography (EMDC) was employed to achieve peptide separations with high efficiency. On-line ESI-MS and ESI-MS/MS measurements showed enrichment and detection of kemptide, a protein kinase A peptide substrate, at low femtomole levels when it was added as a trace marker component to a tryptic digest of bovine serum proteins or to a human growth hormone peptide digest at concentration ratios between 1:10(5) and 1:10(6). In another EMDC separation, five peptides were detected in a mixture containing 20 fmol of human growth hormone tryptic digest mixed with the bovine serum protein digest. We found that EMDC facilitated rapid detection and sequence analysis of trace peptides at levels of approximately 0.5 fmol/microL in complex peptide mixtures with a wide dynamic concentration range. Accordingly, the detection of kemptide by EMDC was found to be 3-4 orders of magnitude more sensitive than that attained in conventional linear elution chromatography separations performed with the same peptide loads. Kemptide was phosphorylated in vitro and was detected along with its neutral loss product in peptide mixtures at low femtomole levels. EMDC enabled both detection and amino acid sequence determination on trace levels of phosphorylated and other posttranslationally modified peptides, suggesting that the technique may be useful for proteomics applications where detection and analysis of trace level peptides are problematic.

Animals↗

High-efficiency peptide analysis on monolithic multimode capillary columns: Pressure-assisted capillary electrochromatography/capillary electrophoresis coupled to UV and electrospray ionization-mass spectrometry.

High-efficiency peptide analysis using multimode pressure-assisted capillary electrochromatography/capillary electrophoresis (pCEC/pCE) monolithic polymeric columns and the separation of model peptide mixtures and protein digests by isocratic and gradient elution under an applied electric field with UV and electrospray ionization-mass spectrometry (ESI-MS) detection is demonstrated. Capillary multipurpose columns were prepared in silanized fused-silica capillaries of 50, 75, and 100 microm inner diameters by thermally induced in situ copolymerization of methacrylic monomers in the presence of n-propanol and formamide as porogens and azobisisobutyronitrile as initiator. N-Ethylbutylamine was used to modify the chromatographic surface of the monolith from neutral to cationic. Monolithic columns were termed as multipurpose or multimode columns because they showed mixed modes of separation mechanisms under different conditions. Anion-exchange separation ability in the liquid chromatography (LC) mode can be determined by the cationic chromatographic surface of the monolith. At acidic pH and high voltage across the column, the monolithic stationary phase provided conditions for predominantly capillary electrophoretic migration of peptides. At basic pH and electric field across the column, enhanced chromatographic retention of peptides on monolithic capillary column made CEC mechanisms of migration responsible for separation. The role of pressure, ionic strength, pH, and organic content of the mobile phase on chromatographic performance was investigated. High efficiencies (exceeding 300 000 plates/m) of the monolithic columns for peptide separations are shown using volatile and nonvolatile, acidic and basic buffers. Good reproducibility and robustness of isocratic and gradient elution pressure-assisted CEC/CE separations were achieved for both UV and ESI-MS detection. Manipulation of the electric field and gradient conditions allowed high-throughput analysis of complex peptide mixtures. A simple design of sheathless electrospray emitter provided effective and robust low dead volume interfacing of monolithic multimode columns with ESI-MS. Gradient elution pressure-assisted mixed-mode separation CE/CEC-ESI-MS mass fingerprinting and data-dependent pCE/pCEC-ESI-MS/MS analysis of a bovine serum albumin (BSA) tryptic digest in less than 5 min yielding high sequence coverage (73%) demonstrated the potential of the method.

Electrophoresis, Capillary↗