Search PubMed⌕ Search

Biomedical subjects

Cristian Cotrutz

Publications and source records attributed to Cristian Cotrutz.

5 recordsLinked to original sources

Segment-based dose optimization using a genetic algorithm.

Intensity modulated radiation therapy (IMRT) inverse planning is conventionally done in two steps. Firstly, the intensity maps of the treatment beams are optimized using a dose optimization algorithm. Each of them is then decomposed into a number of segments using a leaf-sequencing algorithm for delivery. An alternative approach is to pre-assign a fixed number of field apertures and optimize directly the shapes and weights of the apertures. While the latter approach has the advantage of eliminating the leaf-sequencing step, the optimization of aperture shapes is less straightforward than that of beamlet-based optimization because of the complex dependence of the dose on the field shapes, and their weights. In this work we report a genetic algorithm for segment-based optimization. Different from a gradient iterative approach or simulated annealing, the algorithm finds the optimum solution from a population of candidate plans. In this technique, each solution is encoded using three chromosomes: one for the position of the left-bank leaves of each segment, the second for the position of the right-bank and the third for the weights of the segments defined by the first two chromosomes. The convergence towards the optimum is realized by crossover and mutation operators that ensure proper exchange of information between the three chromosomes of all the solutions in the population. The algorithm is applied to a phantom and a prostate case and the results are compared with those obtained using beamlet-based optimization. The main conclusion drawn from this study is that the genetic optimization of segment shapes and weights can produce highly conformal dose distribution. In addition, our study also confirms previous findings that fewer segments are generally needed to generate plans that are comparable with the plans obtained using beamlet-based optimization. Thus the technique may have useful applications in facilitating IMRT treatment planning.

Algorithms↗

IMRT dose shaping with regionally variable penalty scheme.

A commonly known deficiency of currently available inverse planning systems is the difficulty in fine-tuning the final dose distribution. In practice, it is not uncommon that just a few unsatisfactory regions in the planning target volume or an organ at risk prevent an intensity modulated radiation therapy (IMRT) plan from being clinically acceptable. The purpose of this work is to introduce a mechanism for controlling the regional doses after a conventional IMRT plan is obtained and to demonstrate its clinical utility. Two types of importance factors are introduced in the objective function to model the tradeoffs of different clinical objectives. The first is the conventional structure-dependent importance factor, which quantifies the interstructure tradeoff. The second type is the voxel-dependent importance factor which "modulates" the importance of different voxels within a structure. The planning proceeds in two major steps. First a conventional inverse planning is performed, where the structure-dependent importance factors are determined in a trial-and-error fashion. The next level of planning involves fine-tuning the regional doses to meet specific clinical requirements. To achieve this, the voxels where doses need to be modified are identified either graphically on the isodose layouts, or on the corresponding dose-volume histogram (DVH) curves. The importance value of these voxels is then adjusted to increase/decrease the penalty at the corresponding regions. The technique is applied to two clinical cases. It was found that both tumor hot spots and critical structure maximal doses can be easily controlled by varying the regional penalty. One to three trials were sufficient for the conventionally optimized dose distributions to be adjusted to meet clinical expectation. Thus introducing the voxel-dependent penalty scheme provides an effective means for IMRT dose distributions painting and sculpting.

Algorithms↗

Therapeutic treatment plan optimization with probability density-based dose prescription.

The dose optimization in inverse planning is realized under the guidance of an objective function. The prescription doses in a conventional approach are usually rigid values, defining in most instances an ill-conditioned optimization problem. In this work, we propose a more general dose optimization scheme based on a statistical formalism [Xing et al., Med. Phys. 21, 2348-2358 (1999)]. Instead of a rigid dose, the prescription to a structure is specified by a preference function, which describes the user's preference over other doses in case the most desired dose is not attainable. The variation range of the prescription dose and the shape of the preference function are predesigned by the user based on prior clinical experience. Consequently, during the iterative optimization process, the prescription dose is allowed to deviate, with a certain preference level, from the most desired dose. By not restricting the prescription dose to a fixed value, the optimization problem becomes less ill-defined. The conventional inverse planning algorithm represents a special case of the new formalism. An iterative dose optimization algorithm is used to optimize the system. The performance of the proposed technique is systematically studied using a hypothetical C-shaped tumor with an abutting circular critical structure and a prostate case. It is shown that the final dose distribution can be manipulated flexibly by tuning the shape of the preference function and that using a preference function can lead to optimized dose distributions in accordance with the planner's specification. The proposed framework offers an effective mechanism to formalize the planner's priorities over different possible clinical scenarios and incorporate them into dose optimization. The enhanced control over the final plan may greatly facilitate the IMRT treatment planning process.

Algorithms↗

Inverse planning for functional image-guided intensity-modulated radiation therapy.

Radiation therapy is an image-guided process whose success critically depends on the imaging modality used for treatment planning and the level of integration of the available imaging information. In this work, we establish a dose optimization framework for incorporating metabolic information from functional imaging modalities into the intensity-modulated radiation therapy (IMRT) inverse planning process and to demonstrate the technical feasibility of planning deliberately non-uniform dose distributions in accordance with functional imaging data. For this purpose, a metabolic map from functional images is discretized into a number of abnormality levels (ALs) and then fused with CT images. To escalate dose to the metabolically abnormal regions, we assume, for a given spatial point, a linear relation between the AL and the prescribed dose. But the formalism developed here is independent of the assumption and any other relation between AL and prescription is applicable. For a given AL and prescription relation, it is only necessary to prescribe the dose to the lowest AL in the target and the desired doses to other regions with higher AL values are scaled accordingly. To accomplish differential sparing of a sensitive structure when its functional importance (FI) distribution is known, we individualize the tolerance doses of the voxels within the structure according to their Fl levels. An iterative inverse planning algorithm in voxel domain is used to optimize the system with in homogeneous dose prescription. To model intra-structural trade-off, a mechanism is introduced through the use of voxel-dependent weighting factors, in addition to the conventional structure specific weighting factors which model the inter-structural trade-off. The system is used to plan a phantom case with a few hypothetical functional distributions and a brain tumour treatment with incorporation of magnetic resonance spectroscopic imaging data. The results indicated that it is technically feasible to produce deliberately non-uniform dose distributions according to the functional imaging requirements. Integration of functional imaging information into radiation therapy dose optimization allows for consideration of patient-specific biologic information and provides a significant opportunity to truly individualize radiation treatment. This should enhance our capability to safely and intelligently escalate dose and lays the technical foundation for future clinical studies of the efficacy of functional imaging-guided IMRT.

Algorithms↗

Using voxel-dependent importance factors for interactive DVH-based dose optimization.

Intensity modulated radiation therapy (IMRT) inverse planning is usually performed by pre-selecting parameters such as beam modality, beam configuration and importance factors and then optimizing the fluence profiles or beamlet weights. In reality, the IMRT dose optimization problem may be ill-conditioned and there may not be a physical solution to account for the chosen parameters and constraints. Planner intervention is often required to conduct a multiple trial-and-error process where several parameters are sequentially varied until an acceptable compromise is achieved. The resulting solution reflects a balance between the conflicting requirements of the target and the sensitive structures. A major problem of the conventional inverse planning formalism is that there exists no effective mechanism for a planner to fine-tune the dose distribution on a local level or to differentially modify the dose-volume histograms (DVHs) of the involved structures. In this paper we introduce a new inverse planning scheme with voxel-dependent importance factors and demonstrate that it provides us with an effective link between the system parameters and the dosimetric behaviour at a local level. The planning proceeds in two steps. After a conventional trial-and-error inverse planning procedure is completed, we identify the dose interval at which the fractional volume on the DVH curve needs to be changed. The voxels that receive dose in the selected range are then located and their voxel-dependent importance factors are adjusted accordingly. The fine-tuning of the DVHs is iterative in nature and, using widely available computer graphic software tools, the process can be made graphically interactive. The new IMRT planning scheme is applied to two test cases and the results indicate that our control over the differential shapes of the DVHs of the involved structures is,greatly enhanced. Thus the technique may have significant practical implications in facilitating the IMRT treatment planning process.

Algorithms↗