Electrocatalytic detection of thiols using an edge plane pyrolytic graphite electrode.

The first example of using an edge plane pyrolytic graphite electrode in electroanalysis is reported as the determination of homocysteine, N-acetylcysteine, cysteine and glutathione is studied. The response of the electrode in the direct oxidation of thiol moieties is explored and found to be electrocatalytic producing a reduction in the overpotential while having enhanced signal-to-noise characteristics compared to glassy carbon and basal plane pyrolytic graphite electrodes. The effectiveness of the methodology is examined in the determination of cysteine species in a growth tissue media that contains a high number of common biological interferences. The advantageous properties of this electrode for thiol determination lie in its excellent catalytic activity, sensitivity and simplicity.

Journal Article↗

Mercury-free sono-electroanalytical detection of lead in human blood by use of bismuth-film-modified boron-doped diamond electrodes.

We report the electroanalytical determination of lead by anodic stripping voltammetry at in-situ-formed, bismuth-film-modified, boron-doped diamond electrodes. Detection limits in 0.1 mol L(-1) nitric acid solution of 9.6 x 10(-8) mol L(-1) (0.2 ppb) and 1.1 x 10(-8) mol L(-1) (2.3 ppb) were obtained after 60 and 300 s deposition times, respectively. An acoustically assisted deposition procedure was also investigated and found to result in improved limits of detection of 2.6 x 10(-8) mol L(-1) (5.4 ppb) and 8.5 x 10(-10) mol L(-1) (0.18 ppb) for 60 and 300 s accumulation times, respectively. Furthermore, the sensitivity obtained under quiescent and insonated conditions increased from 5.5 (quiescent) to 76.7 A mol(-1) L (insonated) for 60 s accumulation and from 25.8 (quiescent) to 317.6 A mol(-1) L (insonated) for 300 s accumulation. Investigation of the use of ultrasound with diluted blood revealed detection limits of the order of 10(-8) mol L(-1) were achievable with excellent inter- and intra-reproducibility and sensitivity of 411.9 A mol(-1) L. For the first time, electroanalytical detection of lead in diluted blood is shown to be possible by use of insonated in-situ-formed bismuth-film-modified boron-doped diamond electrodes. This method is a rapid, sensitive, and non-toxic means of clinical sensing of lead in whole human blood.

Bismuth↗

Effect of Cu(II) on the electrochemically initiated reaction of thiols with N, N-diethyl- p-phenylenediamine: methodology for the indirect voltammetric determination of Cu(II).

The effect of Cu(II) on the determination of homocysteine via its electrochemically initiated reaction with N, N-diethyl-p-phenylenediamine is examined. The presence of copper inhibited the detection process for homocysteine owing to a complexation reaction occurring. This provided an indirect route for the sensitive and selective determination of Cu(II), which produced a linear response over the range from 2.5 to 500 microM and a limit of detection of 2.5 microM. The detection pathway was examined in the presence of metallic and inorganic ions, with negligible interference observed.

Copper↗

Basal plane pyrolytic graphite modified electrodes: comparison of carbon nanotubes and graphite powder as electrocatalysts.

The oxidations of NADH, epinephrine, and norepinephrine are studied using carbon nanotube and graphite powder-modified basal plane pyrolytic graphite electrodes. Immobilization is achieved in two ways: first, via abrasive attachment of multiwall carbon nanotubes or graphite powder by gently rubbing the electrode surface on a fine quality paper supporting the desired material; second, via "film" modification from dispersing either graphite powder or nanotubes in acetonitrile and pipeting a small volume onto the electrode surface and allowing the solvent to volatilize. While electrocatalytic behavior of both types of nanotube-modified electrodes is shown, with enhanced currents and reduced peak-to-peak separations in the voltammetry in comparison with naked basal plane pyrolytic graphite, similar catalytic behavior is also seen at the graphite powder-modified electrodes. Caution is, therefore, suggested in assigning unique catalytic properties to carbon nanotubes.

Journal Article↗

Ultrasound: promoting electroanalysis in difficult real world media.

This article outlines the recent progress in the field of sonoelectroanalysis with strong emphasis on 'real world media' analysis. General principles of stripping analysis and the effects of ultrasound are explained. A section on 'Electroanalysis in extreme media' presents several examples of applications including detection of copper in beer, manganese in tea, lead and cadmium in saliva. The benefits of diamond electrodes are described and in the final section 'Metal ion detection in blood' several novel approaches based on the use of power ultrasound and based on bismuth electrodes are discussed. Specifically it is shown that the combination of ultrasound with classical stripping voltammetry permits quantifiable measurements in media hitherto impossible to study using conventional methods.

Electrochemistry↗

Sonoelectroanalysis: investigation of bismuth-film-modified glassy carbon electrodes.

Bismuth-modified glassy carbon electrodes have been investigated for their suitability in sonoelectroanalysis. The stability of the bismuth film to the application of ultrasound was assessed via voltammetric and atomic force microscopy (AFM) studies which revealed little ablation at powers up to an intensity of 130 W cm(-2) delivered from a 25-kHz sonic horn. Furthermore, bismuth-film-modified glassy carbon electrodes were evaluated for the sonoelectroanalytical quantification of zinc and cadmium. Detection limits of 2 x 10(-7) M and 6 x 10(-9) M respectively were found after a 60-s deposition time via an acoustically assisted deposition protocol.

Journal Article↗

Amperometric detection of glucose using self-catalytic carbon paste electrodes.

The analytical detection of d-glucose by means of self-catalytic carbon paste electrodes is described. In the construction of these electrodes, carbon powder has been modified with the redox liquid n-butylferrocene, which simultaneously serves both to help bind the paste together whilst also acting as a mediator in the enzymatic oxidation of d-glucose by glucose oxidase. The sensor then functions by monitoring the electrochemical oxidation of the constituent n-butylferrocene itself. Through testing in model glucose solutions, the electrodes were found to yield a linear response over a d-glucose concentration range of 2-20 mM. They were also successfully employed in the determination of d-glucose levels in a spiked blood sample, giving a detection limit of 0.8 mM (based on the 3sigma criterion).

Animals↗

Electroanalytical determination of trace chloride in room-temperature ionic liquids.

The electroanalytical quantification of chloride in [C4mim][BF4], [C4mim][NTf2], and [C4mim][PF6] ionic liquids has been explored using linear sweep and square wave voltammetry. Cathodic stripping voltammetry at a silver disk electrode is found to be the most sensitive. The methodology is based on first holding the potential of the electrode at +2.0 V (vs Ag wire), to accumulate silver chloride at the electrode. On applying a cathodic scan, a stripping wave is observed corresponding to the reduction of the silver chloride. This stripping protocol was found to detect ppb levels of chloride in [C4mim][BF4], [C4mim][NTf2], and [C4mim][PF6]. Although other methods for chloride have been reported for [BF4](-)- and [PF6](-)-based ionic liquids, no methods have been reported for [NTf2](-) ionic liquids.

Journal Article↗

Abrasive immobilization of carbon nanotubes on a basal plane pyrolytic graphite electrode: application to the detection of epinephrine.

The performance of a basal plane pyrolytic graphite (bppg) electrode modified with carbon nanotubes is described. Abrasive immobilization of multiwall carbon nanotubes on a bppg electrode was achieved by gently rubbing the electrode surface on a filter paper supporting carbon nanotubes. The resulting electrode showed excellent mediation of epinephrine oxidation: a decrease in the overvoltage of the epinephrine electro-oxidation (200-500 mV) was observed as well as a dramatic increase in the peak current (4 times) compared to that seen at a bare bppg electrode. The oxidation peaks of epinephrine and ascorbic acid which overlap on bare bppg electrode were separated successfully (by ca. 220 mV) at the surface of the modified bppg electrode. The modified electrode showed good stability in comparison to most modified carbon nanotubes electrodes prepared by alternative methods.

Ascorbic Acid↗

A self-catalytic carbon paste electrode for the detection of vitamin B12.

A simple, sensitive, and selective method for the detection of vitamin B12 (cyanocobalamin) is presented. A carbon paste electrode has been constructed with trans-1,2-dibromocyclohexane (DBCH) acting as both the paste binder and a reactive material facilitating the electrocatalytic detection of the target. The latter reaction is based on the electroreduction of the Co(III) center in vitamin B12 to Co(I), which specifically reacts with DBCH to produce electrocatalytic currents with the regeneration of Co (II); a detection limit of 8.5 x 10(-10) mol dm(-3) (based on 3sigma) was found. The electrode has been successfully used for the quantification of vitamin B12 in pharmaceutical products and biological matrix media.

Carbon↗

Ultrasonically induced phthalocyanine degradation: decolouration vs. metal release.

The ultrasonically induced degradations of nickel(II) 2,9,16,23-tetraphenoxy-29H, 31H-phthalocyanine and vanadyl 2,9,16,23-tetraphenoxy-29H, 31H-phthalocyanine in a biphasic system consisting of chloroform and water are investigated. Decolourisation of the organic phase containing the metallo-phthalocyanines is found to occur rapidly (approximately minutes for 8 ml of ca. 5 microM solution). Analysis of the aqueous solute via ICP-OES, reveals significant amounts of the released nickel ultimately transfers into the aqueous phase but at a rate much slower than that of decolourisation, whereas the vanadium remains within the organic phase suggesting only partial degradation despite efficient decolourisation.

Journal Article↗

Voltammetric exploration and applications of ultrasonic cavitation.

Voltammetric measurements carried out in the presence of power ultrasound are reviewed, and the physical processes responsible for the observed substantial augmentation of mass transport identified as resulting from a mixture of acoustic streaming and cavitation. The benefits conferred in electroanalysis or electrosynthesis of insonation simultaneous with electrolysis are summarised. The use of ultrafast ("nanosecond") voltammetric measurements to probe the nature of the interfacial cavitational bubble dynamics is described and shown to provide information not readily accessed by other experiments. Lastly, voltammetry in acoustically emulsified (organic/aqueous) media is discussed. This has considerable "green" potential for electrosynthesis, whilst the use of nanosecond voltammetry to probe the charge transferred as emulsion droplets impinge on the electrode allows a generic approach to the determination of the potential of zero charge of the latter.