Search PubMed⌕ Search

Biomedical subjects

Craig A Grimes

Publications and source records attributed to Craig A Grimes.

27 records · Page 2Linked to original sources

Magnetoelastic immunosensors: amplified mass immunosorbent assay for detection of Escherichia coli O157:H7.

A mass-sensitive magnetoelastic immunosensor for detection of Escherichia coli O157:H7 is described, based on immobilization of affinity-purified antibodies attached to the surface of a micrometer-scale magnetoelastic cantilever. Alkaline phosphatase is used as a labeled enzyme to the anti-E. coli O157:H7 antibody, amplifying the mass change associated with the antibody-antigen binding reaction by biocatalytic precipitation of 5-bromo-4-chloro-3-indolyl phosphate in a pH 10.0 PBS solution. The detection limit of the biosensor is 10(2) E. coli O157:H7 cells/mL. A linear change in the resonance frequency of the biosensor was found to E. coli O157:H7 concentrations ranging from 10(2) to 10(6) cells/mL.

Biosensing Techniques↗

Characterization of gas-phase adsorption on metal oxide thin films using a magnetoelastic resonance microbalance.

In this study, a magnetoelastic resonance microbalance (MERM) was used to directly measure the gas-phase adsorption behavior of water vapor, isopropyl alcohol, and acetone on a sol-gel-derived titanium dioxide sensor coating. The nature of the MERM platform enables chemical measurements in situations in which wires or physical connections are undesired (or not possible) or in which sensor cost is a major issue. The underlying MERM technique (with an uncoated sensor) showed excellent day-to-day stability, a linear calibration over a 1 kHz change in frequency (or a 1.5-mg change in mass), and the ability to detect a mass change of 15 microg without any efforts at sensitivity optimization. The titanium dioxide coated sensor yielded excellent response to each of the analytes; however, the response did not follow a simple linear calibration function. A more complex calibration model or utilization of the coated sensor in a limited concentration range would be required for quantitative analysis. The process of applying the metal oxide coatings onto the magnetic substrate altered the structure of the thin film layer, resulting in a relatively loose packing of the porous primary titanium dioxide particles to create an open overall honeycomb structure, thereby affecting the adsorption behavior at high relative concentration.

Journal Article↗

Metal oxide nanoarchitectures for environmental sensing.

Metal oxide materials are widely used for gas sensing. Capable of operating at elevated temperatures and in harsh environments, they are mechanically robust and relatively inexpensive and offer exquisite sensing capabilities, the performance of which is dependent upon the nanoscale morphology. In this paper we first review different routes for the fabrication of metal oxide nanoarchitectures useful to sensing applications, including mesoporous thin films, nanowires, and nanotubes. Two sensor test cases are then presented. The first case examines the use of highly uniform nanoporous Al2O3 for humidity sensing; we find that such materials can be successfully used as a wide-range humidity sensor. The second test case examines the use of TiO2 nanotubes for hydrogen sensing. Going from a nitrogen atmosphere to one containing 1000 ppm of hydrogen, at 290 degrees C, 22-nm-diameter titania nanotubes demonstrate a 10(4) change in measured resistance with no measurement hysteresis.

Electrochemistry↗

Synthesis of gold-silica composite nanowires through solid-liquid-solid phase growth.

Nanoscale wires of silicon oxide, and silicon oxide with embedded gold-silicide nanospheres, are synthesized by heating of a gold-coated silicon wafer at temperatures of 1000 degrees C or above, with the resulting wires having diameters ranging from 30 to 150 nm and lengths of approximately 1 mm. This simple fabrication process should make possible economical bulk production of nanowires. Studies indicate that the growth of these gold-silica composite nanowires occurs directly on the silicon wafer by a solid-liquid-solid mechanism.

Crystallization↗

Tracking the harmonic response of magnetically-soft sensors for wireless temperature, stress, and corrosive monitoring.

This paper describes the application of magnetically-soft ribbon-like sensors for measurement of temperature and stress, as well as corrosive monitoring, based upon changes in the amplitudes of the higher-order harmonics generated by the sensors in response to a magnetic interrogation signal. The sensors operate independently of mass loading, and so can be placed or rigidly embedded inside nonmetallic, opaque structures such as concrete or plastic. The passive harmonic-based sensor is remotely monitored through a single coplanar interrogation and detection coil. Effects due to the relative location of the sensor are eliminated by tracking harmonic amplitude ratios, thereby, enabling wide area monitoring. The wireless, passive, mass loading independent nature of the described sensor platform makes it ideally suited for long-term structural monitoring applications, such as measurement of temperature and stress inside concrete structures. A theoretical model is presented to explain the origin and behavior of the higher-order harmonics in response to temperature and stress.

Corrosion↗

Effect of surface roughness on liquid property measurements using mechanically oscillating sensors.

The resonant frequency and quality factor Q of a liquid immersed magnetoelastic sensor are shown to shift linearly with the liquid viscosity and density product. Measurements using different grade oils, organic chemicals, and glycerol-water mixtures show that the surface roughness of the sensor in combination with the molecular size of the liquid play important roles in determining measurement sensitivity, which can be controlled through adjusting the surface roughness of the sensor surface. A theoretical model describing the sensor resonant frequency and quality factor Q as a function of liquid properties is developed using a novel equivalent circuit approach. Experimental results are in agreement with theory when the liquid molecule size is larger than the average surface roughness. However, when the molecular size of the liquid is small relative to the surface roughness features molecules are trapped, and the trapped molecules act both as a mass load and viscous load; the result is higher viscous damping of the sensor than expected.

Biosensing Techniques↗

Characterization of electrochemically deposited polypyrrole using magnetoelastic material transduction elements.

Magnetoelastic alloy films have been used as a working electrode in an electrochemical cell. This material allows magnetic interrogation of electrochemical deposition. This technique was used to monitor the electrochemical deposition of polypyrrole by multisweep (CV) and potentiostatic methods. Since the determination of the mass-sensitive magnetoelastic film's resonance frequency is based on magnetic transduction, an inherent advantage of this method is that it requires no electrical connections other than the working lead of the potentiostat. Increases in pyrrole deposition correlated with a decrease in the peak resonance frequency of the magnetoelastic alloy. This technique provides a novel approach by which one can monitor electrochemical processes.

Alloys↗

Electromagnetic fields on a quantum scale. I.

This is the first in a series of two articles, the second of which provides an exact electro-magnetic field description of photon emission, absorption, and radiation pattern. Photon energy exchanges are analyzed and shown to be the triggered, regenerative response of a non-local eigenstate electron. This first article presents a model-based, hidden variable analysis of quantum theory that provides the statistical nature of wave functions. The analysis uses the equations of classical electro-magnetism and conservation of energy while modeling an eigenstate electron as a nonlocal entity. Essential to the analysis are physical properties that were discovered and analyzed only after the historical interpretation of quantum mechanics was established: electron non-locality and the standing electro-magnetic energy that accompanies and encompasses an active, electrically small volume. The standing energy produces a driving radiation reaction force that, under certain circumstances, is many orders of magnitude larger than currently accepted values. These properties provide a sufficient basis for the Schrödinger equation as a descriptor of non-relativistic eigenstate electrons in or near equilibrium. The uncertainty principle follows, as does the exclusion principle. The analysis leads to atomic stability and causality in the sense that the status of physical phenomena at any instant specifies the status an instant later.

Computer Simulation↗

The exact electromagnetic field description of photon emission, absorption, and radiation pattern. II.

This is the second of two articles, the first of which contains a proposed explanation of quantum theory based upon electron nonlocality and classical electrodynamics. In this second article classical field theory is used to describe a unique field set for exchange of radiation between an atomic eigenstate and the far field. The radiation satisfies the thermodynamic condition of reversibility as described by Boltzmann, Planck, and Einstein. The exchanged radiation supports the kinematic properties of photons, and it can be emitted or absorbed by a vanishingly small volume.

Computer Simulation↗