Optimizing multicompression approaches to elasticity imaging.

Breast lesion visibility in static strain imaging ultimately is noise limited. When correlation and related techniques are applied to estimate local displacements between two echo frames recorded before and after a small deformation, target contrast increases linearly with the amount of deformation applied. However, above some deformation threshold, decorrelation noise increases more than contrast such that lesion visibility is severely reduced. Multicompression methods avoid this problem by accumulating displacements from many small deformations to provide the same net increase in lesion contrast as one large deformation but with minimal decorrelation noise. Unfortunately, multicompression approaches accumulate echo noise (electronic and sampling) with each deformation step as contrast builds so that lesion visibility can be reduced again if the applied deformation increment is too small. This paper uses signal models and analysis techniques to develop multicompression strategies that minimize strain image noise. The analysis predicts that displacement variance is minimal in elastically homogeneous media when the applied strain increment is 0.0035. Predictions are verified experimentally with gelatin phantoms. For in vivo breast imaging, a strain increment as low as 0.0015 is recommended for minimum noise because of the greater elastic heterogeneity of breast tissue.

Algorithms↗

Thyroid gland tumor diagnosis at US elastography.

PURPOSE: To prospectively evaluate the elastographic appearance of thyroid gland tumors and explore the potential sensitivity and specificity of ultrasonographic (US) elastography for differentiating benign and malignant tumors, with histopathologic analysis as the reference standard. MATERIALS AND METHODS: The study was institutional review board approved, and each patient gave written informed consent. Fifty-two thyroid gland lesions (22 malignant, 30 benign) in 31 consecutive patients (six men, 25 women; mean age, 49.7 years +/- 14.7 [standard deviation]) were examined with real-time elastography in the elasticity imaging mode implemented on a clinical US scanner modified for research. In addition, the radiofrequency echo data stored during US were exported from the scanner and used for off-line strain image reconstruction. All elastograms were evaluated for the lesion visibility, relative brightness, and margin regularity and definition by using a four-point scale. In addition, normal thyroid gland tissue and thyroid gland tumor strains were measured on off-line processed elastograms, and the thyroid gland-to-tumor strain ratio (ie, strain index) was calculated. The potential of elastographic criteria for the diagnosis of thyroid gland cancer was evaluated with univariate analysis and multivariate logistic regression. Qualitative variables were compared by using the chi2 test, and quantitative variables were compared by using the Mann-Whitney U test. P < .05 was considered to indicate significance. RESULTS: A strain index value greater than 4 on off-line processed elastograms was the strongest independent predictor of thyroid gland malignancy (P < .001); this criterion had 96% specificity and 82% sensitivity. Two other elastographic criteria, which were evaluated on real-time elastograms--a margin regularity score higher than 3 (88% specificity, 36% sensitivity) and a tumor area ratio higher than 1 (92% specificity, 46% sensitivity)--also were associated with malignancy (P < .05). However, the usefulness of these criteria was not considered to be high because of their low sensitivity. CONCLUSION: Elastography is a promising imaging technique that can assist in the differential diagnosis of thyroid cancer.

Adult↗

Viscoelastic imaging of breast tumor microenvironment with ultrasound.

Imaging systems are most effective for detection and classification when they exploit contrast mechanisms specific to particular disease processes. A common example is mammography, where the contrast depends on local changes in cell density and the presence of microcalcifications. Unfortunately the specificity for classifying malignant breast disease is relatively low for many current diagnostic techniques. This paper describes a new ultrasonic technique for imaging the viscoelastic properties of breast tissue. The mechanical properties of glandular breast tissue, like most biopolymers, react to mechanical stimuli in a manner specific to the microenvironment of the tissue. Elastic properties allow noninvasive imaging of desmoplasia while viscous properties describe metabolism-dependent features such as pH. These ultrasonic methods are providing new tools for studying disease mechanisms as well as improving diagnosis.

Animals↗

Ultrasound elastography based on multiscale estimations of regularized displacement fields.

Elasticity imaging is based on the measurements of local tissue deformation. The approach to ultrasound elasticity imaging presented in this paper relies on the estimation of dense displacement fields by a coarse-to-fine minimization of an energy function that combines constraints of conservation of echo amplitude and displacement field continuity. The multiscale optimization scheme presents several characteristics aimed at improving and accelerating the convergence of the minimization process. This includes the nonregularized initialization at the coarsest resolution and the use of adaptive configuration spaces. Parameters of the energy model and optimization were adjusted using data obtained from a tissue-like phantom material. Elasticity images from normal in vivo breast tissue were subsequently obtained with these parameters. Introducing a smoothness constraint into motion field estimation helped solve ambiguities due to incoherent motion, leading to elastograms less degraded by decorrelation noise than the ones obtained from correlation-based techniques.

Algorithms↗

Gadolinium-enhanced T1-weighted renal and abdominal MR imaging: quantitative discrepancy between clinical and in vitro findings.

RATIONALE AND OBJECTIVES: This study was conducted to compare the magnetic resonance (MR) contrast medium enhancement of abdominal organs in vivo with the signal intensity (SI) values of known in vitro gadolinium solutions. MATERIALS AND METHODS: A phantom was imaged with the MR contrast medium gadodiamide (Omniscan; Nycomed, Princeton, NJ) of solutions at full-strength (0.5 mmol/mL), one-third, 1/10, and 1/100 concentrations. A fat-suppressed fast spoiled gradient-echo pulse sequence with flip angles ranging from 10 degrees to 170 degrees (at 20 degrees increments) was performed with a 1.5-T magnet. In 12 subjects, the SIs of abdominal organs were determined with identical imaging parameters, before and after administration of gadodiamide injection at 0.1 mmol/kg. RESULTS: As anticipated, the plot of SI in relation to gadodiamide concentration is nonlinear, with a decrease in SI due to T2 effects at concentrations above 0.05 mmol/mL. The kidney showed the highest SI after gadodiamide enhancement (125.2 +/- 11.6 [standard error] at 2.5 minutes), followed by the liver (76.5 +/- 11.5 at 1 minute) and spleen (57.26 +/- 9.35 at 30 seconds). The SI of the renal medulla (114.2 +/- 9.8 at 4.5 minutes) was approximately one-third that in phantom observations. CONCLUSION: The authors observed a marked discrepancy between empirical contrast medium performance in abdominal organs and SI values for comparable gadodiamide concentrations in vitro. One possible reason is the intracellular compartmentalization of water molecules in vivo. These results suggest a need for a better understanding of MR contrast medium performance in vivo.

Abdomen↗