Search PubMed⌕ Search

Biomedical subjects

Chuji Wang

Publications and source records attributed to Chuji Wang.

8 recordsLinked to original sources

Making carbon sequestration a paying proposition.

Atmospheric carbon dioxide (CO(2)) has increased from a preindustrial concentration of about 280 ppm to about 367 ppm at present. The increase has closely followed the increase in CO(2) emissions from the use of fossil fuels. Global warming caused by increasing amounts of greenhouse gases in the atmosphere is the major environmental challenge for the 21st century. Reducing worldwide emissions of CO(2) requires multiple mitigation pathways, including reductions in energy consumption, more efficient use of available energy, the application of renewable energy sources, and sequestration. Sequestration is a major tool for managing carbon emissions. In a majority of cases CO(2) is viewed as waste to be disposed; however, with advanced technology, carbon sequestration can become a value-added proposition. There are a number of potential opportunities that render sequestration economically viable. In this study, we review these most economically promising opportunities and pathways of carbon sequestration, including reforestation, best agricultural production, housing and furniture, enhanced oil recovery, coalbed methane (CBM), and CO(2) hydrates. Many of these terrestrial and geological sequestration opportunities are expected to provide a direct economic benefit over that obtained by merely reducing the atmospheric CO(2) loading. Sequestration opportunities in 11 states of the Southeast and South Central United States are discussed. Among the most promising methods for the region include reforestation and CBM. The annual forest carbon sink in this region is estimated to be 76 Tg C/year, which would amount to an expenditure of $11.1-13.9 billion/year. Best management practices could enhance carbon sequestration by 53.9 Tg C/year, accounting for 9.3% of current total annual regional greenhouse gas emission in the next 20 years. Annual carbon storage in housing, furniture, and other wood products in 1998 was estimated to be 13.9 Tg C in the region. Other sequestration options, including the direct injection of CO(2) in deep saline aquifers, mineralization, and biomineralization, are not expected to lead to direct economic gain. More detailed studies are needed for assessing the ultimate changes to the environment and the associated indirect cost savings for carbon sequestration.

Agriculture↗

Development of alternative plasma sources for cavity ring-down measurements of mercury.

We have been exploring innovative technologies for elemental and hyperfine structure measurements using cavity ring-down spectroscopy (CRDS) combined with various plasma sources. A laboratory CRDS system utilizing a tunable dye laser is employed in this work to demonstrate the feasibility of the technology. An in-house fabricated sampling system is used to generate aerosols from solution samples and introduce the aerosols into the plasma source. The ring-down signals are monitored using a photomultiplier tube and recorded using a digital oscilloscope interfaced to a computer. Several microwave plasma discharge devices are tested for mercury CRDS measurement. Various discharge tubes have been designed and tested to reduce background interference and increase the sample path length while still controlling turbulence generated from the plasma gas flow. Significant background reduction has been achieved with the implementation of the newly designed tube-shaped plasma devices, which has resulted in a detection limit of 0.4 ng/mL for mercury with the plasma source CRDS. The calibration curves obtained in this work readily show that linearity over 2 orders of magnitude can be obtained with plasma-CRDS for mercury detection. In this work, the hyperfine structure of mercury at the experimental plasma temperatures is clearly identified. We expect that plasma source cavity ring-down spectroscopy will provide enhanced capabilities for elemental and isotopic measurements.

Journal Article↗

Fiber loop ringdown for physical sensor development: pressure sensor.

A new method of developing optical fiber pressure sensors by use of a fiber loop ringdown scheme is described. The fiber loop ringdown system is characterized in terms of the ringdown baseline stability, fiber transmission loss, and fiber refractive index. The overall sensor performance is demonstrated by use of sensing forces applied to the sensor head. The current device can sense pressures in the range of 0 to 9.8 x 10(6) Pa, converted approximately from the applied forces. The sensor's linear response, repeatability, detection sensitivity, measuring dynamic range, and temperature tolerance are explored.

Journal Article↗

Fiber ringdown pressure sensors.

An exploratory study on a novel fiber ringdown pressure sensor is presented. With this technique, pressure measurements are achieved in a time domain by measurement of ringdown times. The proof-of-concept device consists of a diode laser light source, two 2 x 1 fiber couplers, a section of fused-silica single-mode fiber, a photodetector, and an electronic control. The sensor's performance in the areas of stability, repeatability, and dynamic range is explored. The results demonstrate the new concept of fiber pressure sensors and the technical feasibility of developing a new generation of fiber sensors for pressure measurements.

Journal Article↗

Measurements of cavity ringdown spectroscopy of acetone in the ultraviolet and near-infrared spectral regions: potential for development of a breath analyzer.

We report a study on the cavity ringdown spectroscopy of acetone in both the ultraviolet (UV) and the near-infrared (NIR) spectral regions to explore the potential for development of a breath analyzer for disease diagnostics. The ringdown spectrum of acetone in the UV (282.4-285.0 nm) region is recorded and the spectrum is in good agreement with those obtained by other spectral techniques reported in the literature. The absorption cross-section of the C-H stretching overtone of acetone in the NIR (1632.7-1672.2 nm) is reported for the first time and the maximum absorption cross-section located at 1666.7 nm is 1.2 x 10(-21) cm(2). A novel, compact, atmospheric cavity with a cavity length of 10 cm has been constructed and implemented to investigate the technical feasibility of the potential instrument size, optical configuration, and detection sensitivity. The detection limit of such a mini cavity employing ringdown mirrors of reflectivity of 99.85% at 266 nm, where acetone has the strongest absorption, is approximately 1.5 ppmv based on the standard 3 criteria. No real breath gas samples are used in the present study. Discussions on the detection sensitivity and background spectral interferences for the instrument development are presented. This study demonstrates the potential of developing a portable, sensitive breath analyzer for medical applications using the cavity ringdown spectral technique.

Breath Tests↗

Measurements of OH radicals in a low-power atmospheric inductively coupled plasma by cavity ringdown spectroscopy.

Cavity ringdown spectroscopy is applied to line-of-sight measurements of OH radicals in an atmospheric-pressure argon inductively coupled plasma, operating at low power (200 W) and low gas flows (approximately 18 liters/min). Density populations of the single S21(1) rotational line in the OH A2sigma(+)-X2Pi (0-0) band are extracted from the measured line-of-sight absorbance. Plasma gas kinetic temperatures, derived from the recorded line shapes of the S21(1) line, ranged from 1858 to 2000 K with an average uncertainty of 10%. Assuming local thermodynamic equilibrium, an assumption supported by the comparison of the experimental and simulated spectra, the spatially averaged total OH number density at different observation heights was determined to be in the range of 1.7 x 10(20)-8.5 x 10(20) (m(-3)) with the highest OH density in the plasma tail. This work demonstrates that ringdown spectra of the OH radical may be used both as a thermometer for high-temperature environments and as a diagnostic tool to probe the thermodynamic properties of plasmas.

Argon↗

Exploration of microwave plasma source cavity ring-down spectroscopy for elemental measurements.

We are exploring sensitive techniques for elemental measurements using cavity ring-down spectroscopy (CRDS) combined with a compact microwave plasma source as an atomic absorption cell. The research work marries the high sensitivity of CRDS with a low-power microwave plasma source to develop a new instrument that yields high sensitivity and capability for elemental measurements. CRDS can provide orders of magnitude improvement in sensitivity over conventional absorption techniques. Additional benefit is gained from a compact microwave plasma source that possesses the advantages of low power and low-plasma gas flow rate, which are of benefit for atomic absorption measurements. A laboratory CRDS system consisting of a tunable dye laser is used in this work for developing a scientific base and demonstrating the feasibility of the technique. A laboratory-designed and -built sampling system for solution sample introduction is used for testing. The ring-down signals are monitored using a photomultiplier tube and recorded using a digital oscilloscope interfaced to a computer. Lead is chosen as a typical element for the system optimization and characterization. The effects of baseline noise from the plasma source are reported. A detection limit of 0.8 ppb (10(-)(10)) is obtained with such a device.

Algorithms↗

Isotopic measurements of uranium using inductively coupled plasma cavity ringdown spectroscopy.

Inductively coupled plasma cavity ringdown spectroscopy (ICP-CRDS) is applied to isotopic measurements of uranium. We have successfully obtained the isotopic-resolved spectra of uranium at three different atomic/ionic transition lines, 286.57, 358.49, and 409.01 nm. Of the three lines, the largest isotope shift of approximately 9 pm was measured at the 286.57 ionic line. Isotopic-resolved spectra were recorded in ratio of 1:1 (235U/238U, 2.5 micrograms/mL) and at the natural abundance ratio of 0.714% (235U/238U, 1.25 micrograms/mL 235U). The smallest measurable isotope shift of approximately 3 pm was determined for the 409.01 nm ion spectral line. Detection limits (DL) were obtained under optimized ICP operating conditions to be in the range of 70-150 ng/mL, except for the 238U component of the 286.57 nm line (300 ng/mL). This latter result was determined to be due to a strong, previously unreported, absorption interference from the argon plasma. The 235U isotope component (DL 70 ng/mL) was found to be unaffected. This work demonstrates the applicability of ICP-CRDS for uranium isotopic measurements. The potential of development of a field-deployable, on-line uranium isotope monitor using plasma-CRDS is discussed.

Gases↗