Search PubMed⌕ Search

Biomedical subjects

Chuan Peng

Publications and source records attributed to Chuan Peng.

3 recordsLinked to original sources

Multiwavelength discrimination and measurements of a two-gas mixture by use of a broadly tunable mid-infrared semiconductor laser.

Spectroscopic detection of gases can be achieved by measuring a few species-specific absorption lines, requiring very accurate wavelength control. Alternatively, it can be achieved by using many wavelengths spread over a wide range; each wavelength need not be optimal spectroscopically, but all collectively form a unique fingerprint for the species of interest. Statistical regression can be used to quantify their concentrations. An experimental evaluation of this concept involved using a 3.1 microm broadly tunable Sb-based mid-IR laser to discriminate and measure mixtures of acetylene and water vapor with absorption spectral overlaps. As many as 30 wavelengths from approximately 3200 to approximately 3280 cm-1 were used to measure 5 x 5 combinations of the two-gas concentration. Statistical analysis of the results validates the concept. Each gas concentration was consistently and reliably measured without any problem of interference from the other. In addition, the method was sufficiently sensitivite to detect unusual discrepancies by use of statistical analysis. Optimization of the system's detection capability and its receiver-operating characteristics is demonstrated. The results suggest that the statistical multiwavelength broadband approach to detection of gas mixture can be a highly effective alternative to species-specific single-line spectroscopy.

Journal Article↗

Broadband, continuous, and fine-tune properties of external-cavity thermoelectric-stabilized mid-infrared quantum-cascade lasers.

Continuous, broad, and single-mode wavelength tuning of thermoelectrically cooled short-pulse quantum-cascade lasers is demonstrated with a combination of coarse grating tuning and fine phase tuning of the gain element. This approach overcomes the problem of a poor facet antireflection coating of the gain chip by shifting a Fabry-Perot longitudinal mode to coincide with the desired grating-selected wavelength. The 9-microm laser was tested with NH3 gas absorption and showed fine frequency tuning at a rate of 31 MHz/step and a time-averaged linewidth of 500-750 MHz. The total tuning range was 9.08-9.36 microm and was limited only by the intrinsic gain of the device.

Journal Article↗

[The adjustable, folding and multi-function mount].

An adjustable folding mount is presented in this paper. It is a multi-functional device for one or more patient's infusions, continuous traction and functional training, and life nursing etc.

Equipment and Supplies↗