Christopher T Culbertson

Publications and source records attributed to Christopher T Culbertson.

11 recordsLinked to original sources

The effect of photomask resolution on separation efficiency on microfabricated devices.

Separation quality on glass microfluidic devices fabricated from photomasks of different optical resolutions was compared by measuring the dispersion (apparent diffusion) coefficients of a set of standard compounds separated on these devices. Currently, the channel manifolds of most microfluidic devices are patterned using chrome photomasks. A much cheaper, more robust alternative to chrome photomasks are laser photoplotted masks. The primary disadvantage to using laser photoplots is that the optical resolution of these masks is not as high as that of chrome masks, and this feature increases the side-wall roughness of etched channel manifolds patterned using such masks. The increased wall roughness may affect the fluid flow within the channels and, therefore, the separation quality. To determine the effect of increased sidewall channel roughness, microchip channel manifolds were patterned in soda lime glass using a chrome photomask and laser photoplots printed at resolutions of 620, 1240, 3100 and 6200 dots per centimetre (dpc). Separations were performed on these devices using dilute solutions of fluorescently labeled amino acids. The peak variances of the amino acids were calculated at increasing distances down the separation channel and plotted as a function of migration time. From this plot, dispersion coefficients of the analytes were measured. This allowed for a reliable, relatively easy, direct separation analysis among microchips fabricated from the various photomasks. After multiple separations using microchips fabricated from each resolution mask, we found that the change in sidewall surface roughness did not significantly affect the dispersion coefficients measured, and thus the separation quality. The lower mask resolution limit, rather, was governed by the fidelity to which the mask could capture the original CAD design.

Journal Article↗

Surface engineering of poly(dimethylsiloxane) microfluidic devices using transition metal sol-gel chemistry.

We report the coating of poly(dimethylsiloxane) (PDMS) microchannels using transition metal sol-gel chemistry and the subsequent characterization of the coatings. The channels were created using soft polymer lithography, and three metal alkoxide sol-gel precursors were investigated, titanium isopropoxide, zirconium isopropoxide, and vanadium triisobutoxide oxide. The metal alkoxides were diffused into the sidewalls of a PDMS channel and subsequently hydrolyzed using water vapor. This procedure resulted in the formation of durable metal oxide surfaces of titania, zirconia, or vanadia. The resulting surfaces were characterized using contact angle, X-ray photoelectron spectroscopy (XPS), Raman, transmission electron microscopy (TEM), scanning electron microscopy (SEM), atomic force microscopy (AFM), and electroosmotic mobility (EOM) measurements. All of the metal oxide-modified PDMS surfaces were significantly more hydrophilic than native PDMS. Contact angles for the coatings were 90 degrees for PDMS-ZrO2, 61 degrees for PDMS-TiO2, and 19 degrees for PDMS-vanadia. XPS showed the presence of titania, zirconia, and vanadia on the PDMS surface. XPS spectra also showed no chemical modification of the PDMS after the in situ deposition of the particles either in the Si-O, Si-C, or C-H bonds of the PDMS. The particles deposited in situ were imaged with TEM and were found to be homogeneously distributed throughout the bulk of the PDMS. EOM measurements of the inorganic coatings were stable over a period of at least 95 days. Both cathodic and anodic EOMs could be generated depending upon buffer pH used. The points of net zero charge for PDMS-TiO2, PDMS-ZrO2, and PDMS-vanadia channels were calculated using EOM versus pH measurements and were found to be 4.1 +/- 0.25, 6.1 +/- 0.2, and 7.0 +/- 0.43, respectively. In addition to modifying PDMS channels with inorganic coatings, these inorganic coatings were derivatized with various organic functionalities including oligoethylene oxide (OEO), amino, perfluoro, or mercapto groups using silane chemistry. Contact angle measurements for perfluoro, mercapto, amino, and OEO-coated surfaces yielded contact angles of 120 degrees , 76 degrees , 45 degrees , and 23 degrees , respectively. These contact angles did not change over the period of 95 days. OEO-coated channels reduced the EOM by 50% from native PDMS-TiO2 to 0.9 +/- 0.05 x 10(-4) cm2/V.s (n = 5, 5.5% RSD).

Journal Article↗

Micellar electrokinetic chromatography of fluorescently labeled proteins on poly(dimethylsiloxane)-based microchips.

MEKC of standard proteins was investigated on PDMS microfluidic devices. Standard proteins were labeled with AlexaFluor(R) 488 carboxylic acid tetrafluorophenyl ester and filtered through a size-exclusion column to remove any small peptides and unreacted label. High-efficiency MEKC separations of these standard proteins were performed using a buffer consisting of 10 mM sodium tetraborate, 25 mM SDS, and 20% v/v ACN. A separation of BSA using this buffer in a 3.0 cm long channel generated a peak with a plate height of 0.38 microm in <20 s. Additional fast separations of myoglobin, alpha-lactalbumin, lysozyme, and cytochrome c also yielded peaks with plate heights ranging from 0.54 to 0.72 microm. All proteins migrated with respect to their individual pIs. To improve the separations, we used a PDMS serpentine chip with tapered turns and a separation distance of 25 cm. The number of plates generated increased linearly with increasing separation distance on the extended separation channel chips; however, the resolution reached an asymptotic value after about 7 cm. This limited the peak capacity of the separation technique to 10-12.

Animals↗

Single cell analysis on microfluidic devices.

There is significant variability among cells of the same type at the single cell level. This variability may be because of external stimuli that vary temporally or spatially among a population of cells. It may also be owing to the nonsynchronized responses of cells to various stimuli. In addition, differences in otherwise similar cells may be generated by genetic mutations acquired by one or more of the cells. Often times multiple biochemical pathways and molecules are involved in such differences. In order to better understand these differences and to detect those rare cells in a large population that may be indicative of early disease states, methods that are capable of rapidly quantifying multiple molecular species in single cells are desired. Microfluidic devices may provide the optimal platform upon which to develop such methods. Microfluidics has the capability of combining the high-throughput manipulation and transport of cells with rapid, high-efficiency separations and high-sensitivity detection. This chapter describes how to fabricate microfluidic devices for the high-throughput manipulation and rapid electrical lysis of single, nonadherent (suspension) cells followed by the injection and separation of the fluorescently labeled cell contents.

Carboxylesterase↗

Microchip separations in reduced-gravity and hypergravity environments.

Microfabricated fluidics technology, e.g., lab-on-a-chip devices, offers many attractive features for performing chemistry and biochemistry on space-based platforms. We have constructed a portable, battery-operated microfluidic platform that was tested under reduced gravity and hypergravity conditions that would be experienced in space flight and launch. This device consisted of a microchip, microchip holder, two 0-8-kV high-voltage power supplies, a high-voltage switch, a solid-state diode-pumped green laser, an optical train, a channel photomultiplier, and an inertial mass measurement unit all under the control of a laptop computer and powered by 10 D-cell alkaline batteries. The unit was tested on NASA's reduced gravity research aircraft at gravity levels that are relevant to NASA's intended use of bioreporter-based microchips for environmental monitoring of space and planetary environments on manned and unmanned spacecraft. Over the course of two flights, 834 fast electrophoretic separations of four amino acids were performed under a variety of gravitational environments including zero-g, Martian-g, lunar-g, and approximately 1.8-g. All separations were performed in less than 12 s and automatically analyzed. After correction with an internal migration standard, the migration time reproducibilities were all <1% relative standard deviation.

Journal Article↗

High efficiency micellar electrokinetic chromatography of hydrophobic analytes on poly(dimethylsiloxane) microchips.

This paper describes a simple method for the effective and rapid separation of hydrophobic molecules on polydimethylsiloxane (PDMS) microfluidic devices using Micellar Electrokinetic Chromatography (MEKC). For these separations the addition of sodium dodecyl sulfate (SDS) served two critical roles - it provided a dynamic coating on the channel wall surfaces and formed a pseudo-stationary chromatographic phase. The SDS coating generated an EOF of 7.1 x 10(-4) cm(2) V(-1) s(-1) (1.6% relative standard deviation (RSD), n = 5), and eliminated the absorption of Rhodamine B into the bulk PDMS. High efficiency separations of Rhodamine B, TAMRA (6-carboxytetramethylrhodamine, succinimidyl ester) labeled amino acids (AA), BODIPY FL CASE (N-(4,4-difluoro-5,7-dimethyl-4-bora-3a,4a-diaza-s-indacene-3-propionyl)cysteic acid, succinimidyl ester) labeled AA's, and AlexaFluor 488 labeled Escherichia coli bacterial homogenates on PDMS chips were performed using this method. Separations of Rhodamine B and TAMRA labeled AA's using 25 mM SDS, 20% acetonitrile, and 10 mM sodium tetraborate generated efficiencies > 100,000 plates (N) or 3.3 x 10(6) N m(-1) in <25 s with run-to-run migration time reproducibilities <1% RSD over 3 h. Microchips with 30 cm long serpentine separation channels were used to separate 17 BODIPY FL CASE labeled AA's yielding efficiencies of up to 837,000 plates or 3.0 x 10(6) N m(-1). Homogenates of E. coli yielded approximately 30 resolved peaks with separation efficiencies of up to 600,000 plates or 2.4 x 10(6) N m(-1) and run-to-run migration time reproducibilities of <1% RSD over 3 h.

Amino Acids↗

Sol-gel modified poly(dimethylsiloxane) microfluidic devices with high electroosmotic mobilities and hydrophilic channel wall characteristics.

Using a sol-gel method, we have fabricated poly(dimethylsiloxane) (PDMS) microchips with SiO2 particles homogeneously distributed within the PDMS polymer matrix. These particles are approximately 10 nm in diameter. To fabricate such devices, PDMS (Sylgard 184) was cast against SU-8 molds. After curing, the chips were carefully removed from the mold and sealed against flat, cured pieces of PDMS to form enclosed channel manifolds. These chips were then solvated in tetraethyl orthosilicate (TEOS), causing them to expand. Subsequently, the chips were placed in an aqueous solution containing 2.8% ethylamine and heated to form nanometer-sized SiO2 particles within the cross-linked PDMS polymer. The water contact angle for the PDMS-SiO2 chips was approximately 90.2 degrees compared to a water contact angle for Sylgard 184 of approximately 108.5 degrees . More importantly, the SiO2 modified PDMS chips showed no rhodamine B absorption after 4 h, indicating a substantially more hydrophilic and nonabsorptive surface than native PDMS. Initial electroosmotic mobilities (EOM) of (8.3+/-0.2)x10(-4) cm2/(V.s) (RSD=2.6% (RSD is relative standard deviation); n=10) were measured. This value was approximately twice that of native Sylgard 184 PDMS chips (4.21+/-0.09)x10(-4) cm2/(V.s) (RSD=2.2%; n=10) and 55% greater than glass chips (5.3+/-0.4)x10(-4) cm2/(V.s) (RSD=7.7%; n=5). After 60 days of dry storage, the EOM was (7.6+/-0.3)x10(-4) cm2/(V.s) (RSD=3.9%; n=3), a decrease of only 8% below that of the initially measured value. Separations performed on these devices generated 80,000-100,000 theoretical plates in 6-14 s for both tetramethylrhodamine succidimidyl ester and fluorescein-5-isothiocyanate derivatized amino acids. The separation distance was 3.5 cm. Plots of peak variance vs analyte migration times gave diffusion coefficients which indicate that the separation efficiencies are within 15% of the diffusion limit.

Journal Article↗

Static and dynamic acute cytotoxicity assays on microfluidic devices.

Static and dynamic acute toxicity assays of cells were performed on microfluidic devices where materials were hydraulically transported. Static assays were performed by incubating cells with an agent in a microchip reservoir and optically interrogating the cells after hydrodynamic focusing at a cross intersection. Dynamic assays were performed on a microchip with a 25-cm-long spiral channel where the cells were mixed with an agent and optically monitored 0.1, 12, and 22 cm from the point of mixing. The incubation time was determined by the time needed for cells to transit from the mixing location to the point of detection. Cell viability was determined using the ratio of fluorescence signals from membrane permeant (calcein) and membrane impermeant (propidium iodide) stains. The model system used in this study was the viability of Jurkat cells in the presence of the agent Triton X-100). An average LC50 value of 138 microM for Triton X-100 was obtained for an incubation period of 7-12 min using the static assay. LC50 values obtained with the dynamic assay for 25- and 47-s incubation times were 290 and 250 microM Triton X-100, respectively. Higher LC50 values for the dynamic assay were expected due to the shorter incubation times.

Cell Survival↗

Microfluidic devices for the high-throughput chemical analysis of cells.

A microfluidic device is reported that integrated cell handling, rapid cell lysis, and electrophoretic separation and detection of fluorescent cytosolic dyes. The device function was demonstrated using Jurkat cells that were loaded with the fluorogenic dyes - carboxyfluorescein diacetate, Oregon green carboxylic acid diacetate, or Calcein AM. The loaded cells were hydrodynamically transported from the cell-containing reservoir to a region on the microfluidic device where they were focused and then rapidly lysed using an electric field. Complete lysis was accomplished in <33 ms. The hydrolyzed, fluorescent dyes in the cell lysate were automatically injected into a separation channel on the device and detected 3 mm downstream of the injection point. The total separation time was approximately 2.2 s with absolute migration time reproducibilities of <1% and efficiencies ranging from 2300 to 4000 theoretical plates. Results from 139 cells are reported. A small fraction of these cells, approximately 9%, were found to enzymatically hydrolyze the loaded dyes in a manner significantly different from the majority of the cells. Cell analysis rates of 7-12 cells/min were demonstrated and are >100 times faster than those reported using standard bench-scale capillary electrophoresis.

Algorithms↗

High-efficiency, two-dimensional separations of protein digests on microfluidic devices.

High-efficiency, two-dimensional separations of tryptic digests were achieved using glass microfluidic devices. Following micellar electrokinetic chromatography (MEKC) separations in a 19.6-cm-long serpentine channel, the peptides were rapidly sampled into a 1.3-cm-long second-dimension channel, where they were separated by capillary electrophoresis (CE). The turns in the serpentine channel were asymmetrically tapered to minimize geometrical contributions to band broadening and to provide ample channel length for high-efficiency chromatographic separations. Analysis of rhodamine B injections routinely produced plate numbers of 230000 and 40000 in the first (MEKC) and second (CE) dimensions, respectively, corresponding to plate heights of 0.9 and 0.3 microm. The electric field strengths were 200 V/cm for MEKC and 2400 V/cm for CE. In analysis times less than 15 min, two-dimensional separation of bovine serum albumin tryptic digest produced a peak capacity of 4200 (110 in the first dimension and 38 in the second dimension). The system was used to identify a peptide from a tryptic digest of ovalbumin using standard addition and to distinguish between tryptic digests of human and bovine hemoglobin.

Animals↗