Search PubMed⌕ Search

Biomedical subjects

Christopher I Blauth

Publications and source records attributed to Christopher I Blauth.

3 recordsLinked to original sources

The subcoronary Toronto stentless versus supra-annular Perimount stented replacement aortic valve: early clinical and hemodynamic results of a randomized comparison in 160 patients.

BACKGROUND: A stentless valve is expected to be hemodynamically superior to a stented valve. The aim of this study was to compare early postoperative hemodynamic function and clinical events in a randomized, prospective series of 160 stentless and stented biological replacement aortic valves. METHODS: We randomized 160 consecutive patients on 1 surgeon's list to receive either a Toronto stentless porcine valve (St Jude Medical, Inc, St Paul, Minn) or a Perimount stented bovine pericardial valve (Edwards Lifesciences, Irvine, Calif). Echocardiography was performed at discharge, between 3 and 6 months, and at 1 year after surgery. Statistical analysis was performed by both intention to treat and actual valves implanted. RESULTS: The mean labeled size of both designs of valve was 24.7. There were no statistically significant differences in results at any time interval or whether analysis was performed by actual valves implanted or intention to treat. At 3 to 6 months for the Toronto versus the Perimount valve, the effective orifice area was 1.58 versus 1.66 cm2, the mean pressure difference was 7.54 versus 7.42 mm Hg, and the peak velocity was 2.07 versus 2.0.1 m/s. There was no difference in mortality, regression of left ventricular hypertrophy, or complications other than paraprosthetic regurgitation at 12 months or on follow-up for a proportion of the sample to 8 years. The incidence of regurgitation through the valves was similar for Toronto (10%) and Perimount (13.8%) at 1 year, but mild paraprosthetic regurgitation was found in 5 patients with the Perimount valve and none with Toronto valves. CONCLUSIONS: There were no significant differences in hemodynamic function or clinical events between the stented and stentless biological valves chosen for comparison in the early postoperative period or in preliminary follow-up to 5 years.

Aged↗

Nominal size in six bileaflet mechanical aortic valves: a comparison of orifice size and biologic equivalence.

OBJECTIVES: Nominal size remains the standard by which valves are compared, but its relationship with orifice area and the patient tissue annulus diameter may differ according to valve design. The aims of this study were to measure the orifice size and compare biologic equivalence in six bileaflet mechanical heart valve designs. METHODS: The inflow aspect of each of 29 valves was photographed then digitized, and the maximum internal diameter and orifice area were calculated. Biologic equivalence was assessed with a series of machined polypropylene blocks. RESULTS: The orifice area ranged between 159 and 222 mm(2) for the six size 19 valves. The internal diameter ranged from 1.6 to 4.6 mm less than the manufacturer's nominal size. Biologic equivalence assessed from an estimate of tissue annulus diameter with machined blocks ranged from 1.0 and 3.5 mm larger than nominal size for the intra-annular valves. This diameter ranged from 3.5 mm smaller to 1.5 mm larger than nominal size for the supra-annular valves. CONCLUSION: There are major differences between nominal size and biologic equivalence. This may lead to confusion when attempting to make comparisons between different valve designs with the same nominal size. A clearer sizing nomenclature is required and could be based on in vitro assessment of tissue annulus diameter or an alphanumeric code.

Aortic Valve↗