Search PubMed⌕ Search

Biomedical subjects

Christopher F Beaulieu

Publications and source records attributed to Christopher F Beaulieu.

At least 19 recordsLinked to original sources

Articular cartilage of the knee: rapid three-dimensional MR imaging at 3.0 T with IDEAL balanced steady-state free precession--initial experience.

Institutional review board approval and informed consent were obtained for this HIPAA-compliant study. In this study, iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) balanced steady-state free precession (bSSFP), fat-suppressed bSSFP, and fat-suppressed spoiled gradient-echo (GRE) sequences for 3.0-T magnetic resonance (MR) imaging of articular knee cartilage were prospectively compared in five healthy volunteers. Cartilage and fluid signal-to-noise ratio (SNR), cartilage-fluid contrast-to-noise ratio (CNR), SNR efficiency, CNR efficiency, image quality, and fat suppression were compared. Fat-suppressed bSSFP and IDEAL bSSFP had higher SNR efficiency of cartilage (P < .01) than did GRE. IDEAL bSSFP had higher cartilage-fluid CNR efficiency than did fat-suppressed bSSFP or GRE (P < .01). Fat-suppressed bSSFP and IDEAL bSSFP had higher image quality than did GRE (P < .01). GRE and IDEAL bSSFP had significantly better fat-water separation or fat saturation than did fat-suppressed bSSFP (P < .05). IDEAL bSSFP is a promising method for imaging articular knee cartilage.

Adult↗

T1- and T2-weighted fast spin-echo imaging of the brachial plexus and cervical spine with IDEAL water-fat separation.

PURPOSE: To compare the iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) method with fat-saturated T1-weighted (T1W) and T2W fast spin-echo (FSE) and short-TI inversion recovery (STIR) imaging of the brachial plexus and cervical spine. MATERIALS AND METHODS: Images acquired at 1.5T in five volunteers using fat-saturated T1W and T2W FSE imaging and STIR were compared with T1W and T2W IDEAL-FSE images. Examples of T1W and T2W IDEAL-FSE images acquired in patients are also shown. RESULTS: T1W and T2W IDEAL-FSE demonstrated superior fat suppression (P<0.05) and image quality (P<0.05), compared to T1W and T2W fat-saturated FSE, respectively. SNR performance of T1W-IDEAL-FSE was similar to T1W FSE in the spinal cord (P=0.250) and paraspinous muscles (P=0.78), while T2W IDEAL-FSE had superior SNR in muscle (P=0.02) and CSF (P=0.02), and marginally higher cord SNR (P=0.09). Compared to STIR, T2W IDEAL-FSE demonstrated superior image quality (P<0.05), comparable fat suppression (excellent, P=1.0), and higher SNR performance (P<0.001). CONCLUSION: IDEAL-FSE is a promising method for T1W and T2W imaging of the brachial plexus and cervical spine.

Adipose Tissue↗

Advanced magnetic resonance imaging of articular cartilage.

MRI is one of the most accurate imaging methods available to diagnose disorders of articular cartilage. Conventional two-dimensional and three-dimensional approaches show changes in cartilage morphology. Newer and substantially faster three-dimensional imaging methods show great promise to improve MRI of cartilage. These methods may allow acquisition of fluid-sensitive isotropic data that can be reformatted into arbitrary planes for improved detection and visualization of pathology. Unique MRI contrast mechanisms also allow clinicians to probe cartilage physiology and detect early changes in cartilage macromolecules.

Cartilage, Articular↗

Articular cartilage of the knee: evaluation with fluctuating equilibrium MR imaging--initial experience in healthy volunteers.

Institutional review board approval and informed consent were obtained for this HIPAA-compliant study, whose purpose was to prospectively compare three magnetic resonance (MR) imaging techniques-fluctuating equilibrium, three-dimensional (3D) spoiled gradient-recalled acquisition in the steady state (SPGR), and two-dimensional (2D) fast spin echo (SE)-for evaluating articular cartilage in the knee. The study cohort consisted of 10 healthy volunteers (four men, six women; age range, 26-42 years). Cartilage signal-to-noise ratio (SNR), SNR efficiency, cartilage-fluid contrast-to-noise ratio (CNR), CNR efficiency, image quality, cartilage visibility, and fat suppression were compared. Cartilage volume was compared for the fluctuating equilibrium and 3D SPGR techniques. Compared with 3D SPGR and 2D fast SE, fluctuating equilibrium yielded the highest cartilage SNR efficiency and cartilage-fluid CNR efficiency (P < .01 for both). Image quality was similar with all sequences. Fluctuating equilibrium imaging yielded higher cartilage visibility than did 2D fast SE imaging (P <. 01) but worse fat suppression than did 3D SPGR and 2D fast SE imaging (P < .04). Cartilage volume measurements with fluctuating equilibrium and 3D SPGR were similar. Fluctuating equilibrium MR imaging is a promising method for evaluating articular cartilage in the knee.

Adult↗

CT colonography: influence of 3D viewing and polyp candidate features on interpretation with computer-aided detection.

PURPOSE: To retrospectively determine if three-dimensional (3D) viewing improves radiologists' accuracy in classifying true-positive (TP) and false-positive (FP) polyp candidates identified with computer-aided detection (CAD) and to determine candidate polyp features that are associated with classification accuracy, with known polyps serving as the reference standard. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained; this study was HIPAA compliant. Forty-seven computed tomographic (CT) colonography data sets were obtained in 26 men and 10 women (age range, 42-76 years). Four radiologists classified 705 polyp candidates (53 TP candidates, 652 FP candidates) identified with CAD; initially, only two-dimensional images were used, but these were later supplemented with 3D rendering. Another radiologist unblinded to colonoscopy findings characterized the features of each candidate, assessed colon distention and preparation, and defined the true nature of FP candidates. Receiver operating characteristic curves were used to compare readers' performance, and repeated-measures analysis of variance was used to test features that affect interpretation. RESULTS: Use of 3D viewing improved classification accuracy for three readers and increased the area under the receiver operating characteristic curve to 0.96-0.97 (P<.001). For TP candidates, maximum polyp width (P=.038), polyp height (P=.019), and preparation (P=.004) significantly affected accuracy. For FP candidates, colonic segment (P=.007), attenuation (P<.001), surface smoothness (P<.001), distention (P=.034), preparation (P<.001), and true nature of candidate lesions (P<.001) significantly affected accuracy. CONCLUSION: Use of 3D viewing increases reader accuracy in the classification of polyp candidates identified with CAD. Polyp size and examination quality are significantly associated with accuracy.

Adult↗

"Flying through" and "flying around" a PET/CT scan: Pilot study and development of 3D integrated 18F-FDG PET/CT for virtual bronchoscopy and colonoscopy.

UNLABELLED: The objective of this pilot project was to devise a new image acquisition and processing technique to produce PET/CT images rendered in 3-dimensional (3D) volume that can then be reviewed in several 3D formats such as virtual bronchoscopy and colonoscopy "fly-throughs" and external "fly-arounds." METHODS: We tested the new imaging and processing protocol on 24 patients with various malignancies to determine whether it could dependably acquire and reformat standard tomographic 2-dimensional PET/CT images into 3D renderings. RESULTS: This new technique added helpful information to the diagnostic interpretation for 2 of the 24 patients. Further, in the 6 patients undergoing mediastinoscopy, bronchoscopy, or endoscopy, 3D imaging helped in preprocedural planning. CONCLUSION: In this initial study, we demonstrated both the feasibility of rendering PET/CT images into 3D volumes and the potential clinical utility of this technique for diagnostic lesion characterization and preprocedural planning.

Adult↗

Driven equilibrium magnetic resonance imaging of articular cartilage: initial clinical experience.

PURPOSE: To evaluate three-dimensional driven equilibrium Fourier transform (3D-DEFT) for image quality and detection of articular cartilage lesions in the knee. MATERIALS AND METHODS: We imaged 104 consecutive patients with knee pain with 3D-DEFT and proton density (PD-FSE) and T2-weighted (T2-FSE) fast spin echo. Twenty-four went on to arthroscopy. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) efficiency were measured. Subjective image quality, fat suppression, and cartilage thickness visibility were assessed. Cartilage lesions on 3D-DEFT and T2-FSE were compared with findings outlined in operative reports. RESULTS: SNR efficiency was higher for 3D-DEFT and PD-FSE than for T2-FSE (P < 0.02). 3D-DEFT and PD-FSE showed superior cartilage thickness visibility compared with T2-FSE (P < 0.02). T2-FSE showed better fat suppression and fewer image artifacts than 3D-DEFT (P < 0.04). 3D-DEFT had similar sensitivity and similar specificity for cartilage lesions compared with PD-FSE and T2-FSE. CONCLUSION: 3D-DEFT provides excellent synovial fluid-to-cartilage contrast while preserving signal from cartilage, giving this method a high cartilage SNR. 3D-DEFT shows the full cartilage thickness better than T2-FSE. T2-FSE had superior fat saturation and fewer artifacts than 3D-DEFT. Overall, 3D-DEFT requires further technical development, but is a promising method for imaging articular cartilage.

Arthroscopy↗

Controversies in protocol selection in the imaging of articular cartilage.

Magnetic resonance (MR) imaging, with its unique ability to noninvasively image and characterize soft tissue, has shown promise in assessment of cartilage. The development of new, fast imaging methods with high contrast will improve the MR evaluation of cartilage morphology. In addition to morphological MR imaging methods, MR imaging contrast mechanisms under development may reveal detailed information regarding the physiology of cartilage. However, many of these methods remain to be tested in the clinical setting. Protocol selection for cartilage imaging requires understanding of the patient population and the advantages and limitations of these techniques.

Cartilage Diseases↗

The flexor hallucis longus: tenographic technique and correlation of imaging findings with surgery in 39 ankles.

PURPOSE: To examine the use of tenography for evaluation of the flexor hallucis longus (FHL) sheath. MATERIALS AND METHODS: Institutional review board approval was waived, patient consent was obtained, and the study was HIPAA compliant. Retrospective review of 192 FHL tenograms and associated surgical records identified 39 ankles in 37 patients (17 male, 20 female; mean age +/- standard deviation, 38 years +/- 13.8; range, 14-68 years) in which both tenography and surgery had been performed. Two radiologists reviewed tenographic findings, including contrast agent extravasation, synovial irregularity, stenosis, fibrous bands, sheath outpouching, extent of opacification, and communications with adjacent structures. Alterations in pain after anesthesia of the tendon sheath were also recorded. Surgical reports were reviewed. RESULTS: Thirty-four of 39 tenograms were diagnostic. Some extravasation occurred in nine (45%) of 20 injections with an initial injection method and in two (11%) of 19 with a new injection technique. Synovial irregularity was present in all 34 studies (15 mild, 16 moderate, three severe). Stenoses were identified in 23 (68%) of 34 ankles, fibrous bands were seen in 16 (47%) of 34 ankles, and outpouching of the sheath above a stenosis was present in 13 (38%) of 34 ankles. Communication of the FHL sheath with the ankle, flexor digitorum longus, or subtalar joint occurred in half the cases. Most patients with pain reported relief; relief was complete (100% reduction from preprocedural pain) in eight of 27, moderate (50%-90% reduction) in nine of 27, and mild (<50% reduction) in eight of 27 patients. CONCLUSION: Tenography of the FHL sheath produced diagnostic images in almost all patients and effectively demonstrated abnormalities of the tendon sheath. Pain relief with anesthetic injection helped confirm the FHL sheath as the pain generator.

Adolescent↗

Surface normal overlap: a computer-aided detection algorithm with application to colonic polyps and lung nodules in helical CT.

We developed a novel computer-aided detection (CAD) algorithm called the surface normal overlap method that we applied to colonic polyp detection and lung nodule detection in helical computed tomography (CT) images. We demonstrate some of the theoretical aspects of this algorithm using a statistical shape model. The algorithm was then optimized on simulated CT data and evaluated using a per-lesion cross-validation on 8 CT colonography datasets and on 8 chest CT datasets. It is able to achieve 100% sensitivity for colonic polyps 10 mm and larger at 7.0 false positives (FPs)/dataset and 90% sensitivity for solid lung nodules 6 mm and larger at 5.6 FP/dataset.

Algorithms↗

Automatic detection and classification of hypodense hepatic lesions on contrast-enhanced venous-phase CT.

The objective of this work was to develop and validate algorithms for detection and classification of hypodense hepatic lesions, specifically cysts, hemangiomas, and metastases from CT scans in the portal venous phase of enhancement. Fifty-six CT sections from 51 patients were used as representative of common hypodense liver lesions, including 22 simple cysts, 11 hemangiomas, 22 metastases, and 1 image containing both a cyst and a hemangioma. The detection algorithm uses intensity-based histogram methods to find central lesions, followed by liver contour refinement to identify peripheral lesions. The classification algorithm operates on the focal lesions identified during detection, and includes shape-based segmentation, edge pixel weighting, and lesion texture filtering. Support vector machines are then used to perform a pair-wise lesion classification. For the detection algorithm, 80% lesion sensitivity was achieved at approximately 0.3 false positives (FP) per slice for central lesions, and 0.5 FP per slice for peripheral lesions, giving a total of 0.8 FP per section. For 90% sensitivity, the total number of FP rises to about 2.2 per section. The pair-wise classification yielded good discrimination between cysts and metastases (at 95% sensitivity for detection of metastases, only about 5% of cysts are incorrectly classified as metastases), perfect discrimination between hemangiomas and cysts, and was least accurate in discriminating between hemangiomas and metastases (at 90% sensitivity for detection of hemangiomas, about 28% of metastases were incorrectly classified as hemangiomas). Initial implementations of our algorithms are promising for automating liver lesion detection and classification.

Algorithms↗

Registration of central paths and colonic polyps between supine and prone scans in computed tomography colonography: pilot study.

Computed tomography colonography (CTC) is a minimally invasive method that allows the evaluation of the colon wall from CT sections of the abdomen/pelvis. The primary goal of CTC is to detect colonic polyps, precursors to colorectal cancer. Because imperfect cleansing and distension can cause portions of the colon wall to be collapsed, covered with water, and/or covered with retained stool, patients are scanned in both prone and supine positions. We believe that both reading efficiency and computer aided detection (CAD) of CTC images can be improved by accurate registration of data from the supine and prone positions. We developed a two-stage approach that first registers the colonic central paths using a heuristic and automated algorithm and then matches polyps or polyp candidates (CAD hits) by a statistical approach. We evaluated the registration algorithm on 24 patient cases. After path registration, the mean misalignment distance between prone and supine identical anatomic landmarks was reduced from 47.08 to 12.66 mm, a 73% improvement. The polyp registration algorithm was specifically evaluated using eight patient cases for which radiologists identified polyps separately for both supine and prone data sets, and then manually registered corresponding pairs. The algorithm correctly matched 78% of these pairs without user input. The algorithm was also applied to the 30 highest-scoring CAD hits in the prone and supine scans and showed a success rate of 50% in automatically registering corresponding polyp pairs. Finally, we computed the average number of CAD hits that need to be manually compared in order to find the correct matches among the top 30 CAD hits. With polyp registration, the average number of comparisons was 1.78 per polyp, as opposed to 4.28 comparisons without polyp registration.

Algorithms↗

Asymmetric closure of ischiopubic synchondrosis in pediatric patients: correlation with foot dominance.

OBJECTIVE: The enlarged ischiopubic synchondrosis is a well-known anatomic structure; however, little is known about its physiology. In early childhood, enlargement of this synchondrosis occurs bilaterally, whereas before complete ossification, it is frequently found unilaterally. In most children, the unilateral enlarged ischiopubic synchondrosis is observed in the left hemipelvis, a finding that was hitherto unexplained. During common athletic activities, increased ground reaction forces are exerted on the weight-bearing nondominant limb, which in up to 87% of the general population is the left leg. The asymmetric exertion of these forces may explain the distinct closure sequence of this temporary joint. The purpose of this study was to correlate unilateral enlarged ischiopubic synchondrosis with foot dominance. MATERIALS AND METHODS: The study cohort comprised 32 children who had undergone unenhanced radiography, CT, or MRI for reasons other than bone disorders and who presented with enlarged ischiopubic synchondroses. In these children, the distribution of enlarged ischiopubic synchondrosis and foot dominance were evaluated either retrospectively (n = 11) or prospectively (n = 21). RESULTS: In this cohort, 78% of patients were right-footed and 22% were left-footed. Nine of the 32 children presented with unilateral enlarged ischiopubic synchondrosis (left, seven [78%] of nine; right, two [22%] of nine). All children with enlarged left ischiopubic synchondrosis were right-footed, and all children with enlarged right ischiopubic synchondrosis were left-footed. CONCLUSION: Unilateral enlarged ischiopubic synchondrosis is closely correlated with foot dominance. The asymmetric ossification pattern of the ischiopubic synchondrosis indicates delayed ossification of this anatomic structure due to asymmetrically applied mechanical forces to the nondominant limb.

Adolescent↗

Circular tomosynthesis: potential in imaging of breast and upper cervical spine--preliminary phantom and in vitro study.

Phantom and in vitro studies were performed to evaluate the potential application of digital circular tomosynthesis in imaging of the breast and upper cervical spine. A prototype volumetric x-ray system was used to image a mammographic phantom, a fresh mastectomy specimen, and a head phantom containing the upper cervical spine. Results show that breast tissue visualization is improved by the ability to produce sectional images that blur overlying structures and yield three-dimensional information about calcification clusters. In upper cervical spine imaging, digital circular tomosynthesis effectively blurs overlying jaw and skull structures so that C1 and C2 can be visualized in a standard anteroposterior view.

Cervical Vertebrae↗

Comparison of new sequences for high-resolution cartilage imaging.

The high prevalence of osteoarthritis continues to demand improved accuracy in detecting cartilage injury and monitoring its response to different treatments. MRI is the most accurate noninvasive method of diagnosing cartilage lesions. However, MR imaging of cartilage is limited by scan time, signal-to-noise ratio (SNR), and image contrast. Recently, there has been renewed interest in SNR-efficient imaging sequences for imaging cartilage, including various forms of steady-state free-precession as well as driven-equilibrium imaging. This work compares several of these sequences with existing methods, both theoretically and in normal volunteers. Results show that the new steady-state methods increase SNR-efficiency by as much as 30% and improve cartilage-synovial fluid contrast by a factor of three. Additionally, these methods markedly decrease minimum scan times, while providing 3D coverage without the characteristic blurring seen in fast spin-echo images.

Cartilage↗