Search PubMed⌕ Search

Biomedical subjects

Christophe Masselon

Publications and source records attributed to Christophe Masselon.

13 recordsLinked to original sources

Both L-Lactyl and D-Lactyl Enantiomers Modify Histones in Mouse Testis.

Dynamic histone posttranslational modifications are crucial to precisely orchestrate gene expression programs. The recently discovered histone lysine lactylation has already been explored in various pathological contexts, but less in normal tissues. This modification exists as two enantiomers, L- and D-lactylation; the former may more likely modify histones due to abundant L-lactate produced by glycolysis. Here, we report the identification by proteomics of L- and D-lactylation on lysines of histones H3 and H4 in mouse testis. We developed a targeted proteomic analysis of histone peptides using synthetic sequences modified by L- or D-lactyl, to acquire reliable identification and quantification data. Some histone peptides bearing either enantiomer are separated by reversed-phase chromatography. Interestingly, despite the fact that L-lactate is much more abundant than D-lactate in mouse testis, we estimated abundance ratios of L-over D-lactylation to lie between 0.4 and 1.6 on seven residues of histones H3 and H4. Next, targeted proteomic analyses were performed on histones extracted from meiotic and postmeiotic male germ cells (spermatocytes and round spermatids, respectively), which are known to use L-lactate as a main source of energy. Nonetheless, residues 18 and 23 of histone H3 (H3K18 and H3K23) were reliably quantified and shown to harbor balanced amounts of both enantiomers. The stoichiometry of lactylation is low over the whole sequence of H3 and H4, representing about 0.01 to 0.44%: this contrasts with acetylation which exists at up to 25 to 35% relative abundances on some N-terminal lysines. Yet, lactylation appears to be more abundant than acetylation on the C-terminal half of H3 and H4, where the latter modification is scarce. Collectively, our results suggest a mechanism producing a mixture of the two enantiomers of lactate, or of a more direct substrate for lactylation, that leads to the modification of histones by L- and D-lactylation.

Animals↗

Targeted comparative proteomics by liquid chromatography-tandem Fourier ion cyclotron resonance mass spectrometry.

In proteomics, effective methods are needed for identifying the relatively limited subset of proteins displaying significant changes in abundance between two samples. One way to accomplish this task is to target for identification by MS/MS only the "interesting" proteins based on the abundance ratio of isotopically labeled pairs of peptides. We have developed the software and hardware tools for online LC-FTICR MS/MS studies in which a set of initially unidentified peptides from a proteome analysis can be selected for identification based on their distinctive changes in abundance following a "perturbation". We report here the validation of this method using a mixture of standard proteins combined in different ratios after isotopic labeling. We also demonstrate the application of this method to the identification of Shewanella oneidensis peptides/proteins exhibiting differential abundance in suboxic versus aerobic cell cultures.

Bacterial Proteins↗

Ultrasensitive proteomics using high-efficiency on-line micro-SPE-nanoLC-nanoESI MS and MS/MS.

Ultrasensitive nanoscale proteomics approaches for characterizing proteins from complex proteomic samples of <50 ng of total mass are described. Protein identifications from 0.5 pg of whole proteome extracts were enabled by ultrahigh sensitivity (<75 zmol for individual proteins) achieved using high-efficiency (peak capacities of approximately 10(3)) 15-microm-i.d. capillary liquid chromatography separations (i.e., using nanoLC, approximately 20 nL/min mobile-phase flow rate at the optimal linear velocity of approximately 0.2 cm/s) coupled on-line with a micro-solid-phase sample extraction and a nanoscale electrospray ionization interface to a 11.4-T Fourier transform ion cyclotron resonance (FTICR) mass spectrometer (MS). Proteome measurement coverage improved as sample size was increased from as little as 0.5 pg of sample. It was found that a 2.5-ng sample provided 14% coverage of all annotated open reading frames for the microorganism Deinococcus radiodurans, consistent with previous results for a specific culture condition. The estimated detection dynamic range for detected proteins was 10(5)-10(6). An improved accurate mass and LC elution time two-dimensional data analysis methodology, used to both speed and increase the confidence of peptide/protein identifications, enabled identification of 872 proteins/run from a single 3-h nanoLC/FTICR MS analysis. The low-zeptomole-level sensitivity provides a basis for extending proteomics studies to smaller cell populations and potentially to a single mammalian cell. Application with ion trap MS/MS instrumentation allowed protein identification from 50 pg (total mass) of proteomic samples (i.e., approximately 100 times larger than FTICR MS), corresponding to a sensitivity of approximately 7 amol for individual proteins. Compared with single-stage FTICR measurements, ion trap MS/MS provided a much lower proteome measurement coverage and dynamic range for a given analysis time and sample quantity.

Amino Acid Sequence↗

Proteomic analyses using an accurate mass and time tag strategy.

An accurate mass and time (AMT) tag approach for proteomic analyses has been developed over the past several years to facilitate comprehensive high-throughput proteomic measurements. An AMT tag database for an organism, tissue, or cell line is established by initially performing standard shotgun proteomic analysis and, most importantly, by validating peptide identifications using the mass measurement accuracy of Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS) and liquid chromatography (LC) elution time constraint. Creation of an AMT tag database largely obviates the need for subsequent MS/MS analyses, and thus facilitates high-throughput analyses. The strength of this technology resides in the ability to achieve highly efficient and reproducible one-dimensional reversed-phased LC separations in conjunction with highly accurate mass measurements using FTICR MS. Recent improvements allow for the analysis of as little as picrogram amounts of proteome samples by minimizing sample handling and maximizing peptide recovery. The nanoproteomics platform has also demonstrated the ability to detect >10(6) differences in protein abundances and identify more abundant proteins from subpicogram amounts of samples. The AMT tag approach is poised to become a new standard technique for the in-depth and high-throughput analysis of complex organisms and clinical samples, with the potential to extend the analysis to a single mammalian cell.

Amino Acid Sequence↗

High-efficiency on-line solid-phase extraction coupling to 15-150-microm-i.d. column liquid chromatography for proteomic analysis.

The ability to manipulate and effectively utilize small proteomic samples is important for analyses using liquid chromatography (LC) in combination with mass spectrometry (MS) and becomes more challenging for very low flow rates due to extra column volume effects on separation quality. Here we report on the use of commercial switching valves (150-microm channels) for implementing the on-line coupling of capillary LC columns operated at 10,000 psi with relatively large solid-phase extraction (SPE) columns. With the use of optimized column connections, switching modes, and SPE column dimensions, high-efficiency on-line SPE-capillary and nanoscale LC separations were obtained demonstrating peak capacities of approximately 1000 for capillaries having inner diameters between 15 and 150 microm. The on-line coupled SPE columns increased the sample processing capacity by approximately 400-fold for sample solution volume and approximately 10-fold for sample mass. The proteomic applications of this on-line SPE-capillary LC system were evaluated for analysis of both soluble and membrane protein tryptic digests. Using an ion trap tandem MS it was typically feasible to identify 1100-1500 unique peptides in a 5-h analysis. Peptides extracted from the SPE column and then eluted from the LC column covered a hydrophilicity/hydrophobicity range that included an estimated approximately 98% of all tryptic peptides. The SPE-capillary LC implementation also facilitates automation and enables use of both disposable SPE columns and electrospray emitters, providing a robust basis for automated proteomic analyses.

Amino Acid Sequence↗

Identification of tryptic peptides from large databases using multiplexed tandem mass spectrometry: simulations and experimental results.

Multiplexed tandem mass spectrometry (MS/MS) has recently been demonstrated as a means to increase the throughput of peptide identification in liquid chromatography (LC) MS/MS experiments. In this approach, a set of parent species is dissociated simultaneously and measured in a single spectrum (in the same manner that a single parent ion is conventionally studied), providing a gain in sensitivity and throughput proportional to the number of species that can be simultaneously addressed. In the present work, simulations performed using the Caenorhabditis elegans predicted proteins database show that multiplexed MS/MS data allow the identification of tryptic peptides from mixtures of up to ten peptides from a single dataset with only three "y" or "b" fragments per peptide and a mass accuracy of 2.5 to 5 ppm. At this level of database and data complexity, 98% of the 500 peptides considered in the simulation were correctly identified. This compares favorably with the rates obtained for classical MS/MS at more modest mass measurement accuracy. LC multiplexed Fourier transform-ion cyclotron resonance MS/MS data obtained from a 66 kDa protein (bovine serum albumin) tryptic digest sample are presented to illustrate the approach, and confirm that peptides can be effectively identified from the C. elegans database to which the protein sequence had been appended.

Algorithms↗

Global analysis of the Deinococcus radiodurans proteome by using accurate mass tags.

Understanding biological systems and the roles of their constituents is facilitated by the ability to make quantitative, sensitive, and comprehensive measurements of how their proteome changes, e.g., in response to environmental perturbations. To this end, we have developed a high-throughput methodology to characterize an organism's dynamic proteome based on the combination of global enzymatic digestion, high-resolution liquid chromatographic separations, and analysis by Fourier transform ion cyclotron resonance mass spectrometry. The peptides produced serve as accurate mass tags for the proteins and have been used to identify with high confidence >61% of the predicted proteome for the ionizing radiation-resistant bacterium Deinococcus radiodurans. This fraction represents the broadest proteome coverage for any organism to date and includes 715 proteins previously annotated as either hypothetical or conserved hypothetical.

Bacteria↗

Mass measurement errors caused by 'local" frequency perturbations in FTICR mass spectrometry.

One of the key qualities of mass spectrometric measurements for biomolecules is the mass measurement accuracy (MMA) obtained. FTICR presently provides the highest MMA over a broad m/z range. However, due to space charge effects, the achievable MMA crucially depends on the number of ions trapped in the ICR cell for a measurement. Thus, beyond some point, as the effective sensitivity and dynamic range of a measurement increase, MMA tends to decrease. While analyzing deviations from the commonly used calibration law in FTICR we have found systematic errors which are not accounted for by a "global" space charge correction approach. The analysis of these errors and their dependence on charge population and post-excite radius have led us to conclude that each ion cloud experiences a different interaction with other ion clouds. We propose a novel calibration function which is shown to provide an improvement in MMA for all the spectra studied.

Chemistry, Physical↗

Increased proteome coverage for quantitative peptide abundance measurements based upon high performance separations and DREAMS FTICR mass spectrometry.

A primary challenge in proteome measurements is to be able to detect, identify, and quantify the extremely complex mixtures of proteins. The relative abundances of interest span at least six orders of magnitude for mammalian proteomes, and this constitutes an intractable challenge for high throughput proteome studies. We have recently described a new approach, Dynamic Range Enhancement Applied to Mass Spectrometry (DREAMS), which is based upon the selective ejection of the most abundant species to expand the dynamic range of Fourier transform ion cyclotron resonanace (FTICR) measurements. The basis of our approach is on-the-fly data-dependent selective ejection of highly abundant species, followed by prolonged accumulation of remaining low-abundance species in a quadrupole external to the FTICR ion trap. Here we report the initial implementation of this approach with high efficiency capillary reverse phase LC separations and high magnetic field electrospray ionization FTICR mass spectrometry for obtaining enhanced coverage in quantitative measurements for mammalian proteomes. We describe the analysis of a sample derived from a tryptic digest of proteins from mouse B16 cells cultured in both natural isotopic abundance and 15N-labeled media. The FTICR mass spectrometric analysis allows the assignment of peptide pairs (corresponding to the two distinctive versions of each peptide), and thus provides the basis for quantiative measurements when one of the two proteomes in the mixture is perturbed or altered in some fashion. We show that implementation of the DREAMS approach allows assignment of approximately 80% more peptide pairs, thus providing quantitative information for approximately 18,000 peptide pairs in a single analysis.

Animals↗

The use of accurate mass tags for high-throughput microbial proteomics.

We describe and review progress towards a global strategy that aims to extend the sensitivity, dynamic range, comprehensiveness, and throughput of proteomic measurements for microbial systems based upon the use of polypeptide accurate mass tags (AMTs) produced by global protein enzymatic digestions. The two-stage strategy exploits high accuracy mass measurements using Fourier transform ion cyclotron resonance mass spectrometry (FTICR) to validate polypeptide AMTs for a specific organism, from potential mass tags tentatively identified using tandem mass spectrometry (MS/MS), providing the basis for subsequent measurements without the need for routine MS/MS. A high-resolution capillary liquid chromatography separation combined with high sensitivity, and high-resolution accurate FTICR measurements is shown to be capable of characterizing polypeptide mixtures of more than 10(5) components, sufficient for broad protein identification using AMTs. Advantages of the approach include the high confidence of protein identification, its broad proteome coverage, and the capability for stable-isotope labeling methods for precise relative protein abundance measurements. The strategy has been initially evaluated using the microorganisms Saccharomyces cerevisiae and Deinococcus radiodurans. Additional developments, including the use of multiplexed-MS/MS capabilities and methods for dynamic range expansion of proteome measurements that promise to further extend the quality of proteomics measurements, are also described.

Amino Acid Sequence↗