Search PubMed⌕ Search

Biomedical subjects

Christoph Vogt

Publications and source records attributed to Christoph Vogt.

12 recordsLinked to original sources

Combined mutations of canalicular transporter proteins cause severe intrahepatic cholestasis of pregnancy.

Intrahepatic cholestasis of pregnancy (ICP) is a cholestatic disorder that usually develops in the third trimester of pregnancy and persists until delivery. The cause of ICP remains elusive, but there is evidence that mutations in the canalicular ABC transporter phospholipid flippase (MDR3) and in the bile salt export pump (BSEP) can predispose for the development of ICP. MDR3 and BSEP were investigated by gene sequencing and immunofluorescence microscopy in a patient with severe ICP of early onset. ICP was diagnosed in a patient in the first trimester of pregnancy with severe pruritus, elevated levels of bile salts, and 48-fold elevation of transaminase levels. A liver biopsy specimen showed diminished canalicular expression of the bile salt export pump BSEP, while the expression and localization of the phospholipid flippase MDR3 was normal. Gene sequencing revealed a homozygous MDR3 gene mutation (S320F). The patient was also homozygous for the common BSEP polymorphism V444A. Treatment with ursodeoxycholate normalized transaminase levels but could not prevent further elevation of bile salt levels and preterm delivery. The combined homozygous alterations of the canalicular transporters may explain the early onset and severity of ICP in this patient. The common BSEP polymorphism V444A accounts for the reduced canalicular BSEP expression. Reduced bile salt secretion through BSEP may explain the persistence of elevated bile salt levels and incomplete efficacy of ursodeoxycholate treatment.

ATP Binding Cassette Transporter, Subfamily B↗

Multi-detector CT-colonography in inflammatory bowel disease: prospective analysis of CT-findings to high-resolution video colonoscopy.

AIM: Prospective analysis of multi-detector CT-colonography (MDCTC) in patients with inflammatory bowel disease (IBD) compared to high-resolution video-endoscopy (HRVC). MATERIALS AND METHODS: Twenty-one patients (mean age 49.6 years) with Crohn's disease or ulcerative colitis underwent MDCTC (Somatom Volume Zoom, Siemens, Erlangen; 1mm collimation, Pitch 8, 100 mAs, 120 kVp). HRVC was performed within 2 h after MDCTC. MDCTC was analyzed by two blinded readers. MDCTC-findings including bowel wall alterations and extraintestinal changes were compared to results of HRVC. RESULTS: Over-all-sensitivity was 100% for endoluminal lesions with correct diagnosis of two cancers. Acute and chronic IBD were correctly identified by MDCTC in 63.6%, and 100%, respectively, with a specificity of 75%, and 100%. Sensitivity, specificity, positive and negative predictive values of MDCTC for diagnosis of acute and chronic disease were best for chronic disease. Sensitivity was worst for acute ulcerative colitis and specificity was worst for acute Crohn's disease. Haustral loss was seen only in ulcerative colitis. Pseudopolyps and fistulae were findings exclusive to Crohn's disease. Particularly extraintestinal findings as increased vascularization and local lymphadenopathy correlated well with endoscopic definition of acute disease. Because of the possibly more vulnerable colonic wall in acute inflammatory bowel disease, the air inflation for MDCTC should be performed most carefully to avoid any risk of colonic perforation. CONCLUSION: MDCTC may help to distinguish between patients with acute and chronic IBD. Especially extraintestinal complications, tumorous as well as pseudo-tumorous lesions can be detected with high sensitivity and specificity.

Adult↗

Time-trends in the epidemiology of peptic ulcer bleeding.

OBJECTIVE: Despite the introduction of effective medical treatment of peptic ulcer disease, bleeding is still a frequent complication. The aim of this study was to investigate whether the incidence and the risk profile of peptic ulcer haemorrhage have changed within a 10-year period. MATERIAL AND METHODS: In a prospective epidemiological and observational study the incidence and risk profile of peptic ulcer haemorrhage in Düsseldorf, Germany were compared between two time periods (period A: 1.3.89-28.2.90 and period B: 1.4.99-31.3.2000), involving nine hospitals with both surgical and medical departments. Patients with proven peptic ulcer haemorrhage at endoscopy or operation were included in the study; those with bleeding under defined severe stress conditions were excluded. RESULTS: No differences in bleeding ulcer incidence were observed between periods A and B (51.4 per 100,000 person-years versus 48.7), or for duodenal ulcer (24.9 versus 25.7) or for gastric ulcer bleeding (26.5 versus 23.0). A marked increase in incidence rates was observed with increasing age. In period B, patients with bleeding ulcers were older (56% versus 41% 70 years or older), were usually taking non-steroidal anti-inflammatory drugs (NSAIDs) (45% versus 27%) and were less likely to have a history of ulcer (25% versus 59%) compared with patients in period A. CONCLUSIONS: The persisting high incidence of peptic ulcer disease is a superimposing of two trends: a higher incidence in the growing population of elderly patient with a higher intake of NSAIDs and a lower incidence among younger patients due to a decrease in incidence and improved medical treatment.

Adult↗

[Contrast-enhanced sonography using Levovist is decisive for staging and therapeutic schedule in hepatocellular carcinoma].

In a 65-year-old female patient, B-mode sonography detected a single focal lesion in the right liver lobe with a diameter < 3 cm. Histopathologic examination revealed a low differentiated hepatocellular carcinoma (HCC; G3). Tumor staging was performed by CT (computed tomography) scan and Resovist MRI (magnetic resonance imaging). Both examinations found a single liver lesion without signs of additional focal hepatic lesions. In addition, phase-inversion sonography in the late phase was performed using the ultrasound contrast agent Levovist. This examination of late-phase Levovist uptake detected more than five additional focal hepatic lesions in the right liver lobe, which were invisible by CT scan and Resovist MRI. This finding of multiloculated HCC was very important to decide on the patient's correct therapy. While liver transplantation is the treatment of choice in single HCC < 3 cm, it is contraindicated in multicentric HCC. In the patient described here, hemihepatectomy of the right liver lobe was performed. The histopathologic examination of the resected liver confirmed the diagnosis of multicentric HCC, which was noninvasively diagnosed only by contrast-enhanced sonography, but not by CT scan or MRI.

Aged↗

Detection of colorectal polyps by multislice CT colonography with ultra-low-dose technique: comparison with high-resolution videocolonoscopy.

BACKGROUND: This prospective study compared multislice CT colonography with ultra-low-dose technique to high-resolution videocolonoscopy as the standard for detection of colorectal cancer and polyps. METHODS: After standard bowel preparation, 115 patients underwent multislice CT colonography with an ultra-low-dose multislice CT colonography protocol immediately before videocolonoscopy. After noise reduction by using a mathematical algorithm, ultra-low-dose multislice CT colonographic images were analyzed in blinded fashion, and the results were compared with the results of high-resolution videocolonoscopy. RESULTS: A total of 150 lesions were detected by high-resolution videocolonoscopy in 115 patients. For ultra-low-dose multislice CT colonography, sensitivities for detection of polyps less than 5 mm in size, 5 to 10 mm, and greater than 10 mm in diameter were 76%, 91%, and 100%, respectively. Although the sensitivity for detection of flat lesions was only 50%, the sensitivity and the specificity for detection of polyps 5 mm or greater in size were 94% and 84%, respectively. For adenomatous lesions greater than 5 mm in size, sensitivity was 94% and specificity was 92%. The overall specificity was 79%. The calculated effective radiation dose ranged between 0.75 and 1.25 mSv. CONCLUSIONS: Compared with high-resolution videocolonoscopy, ultra-low-dose multislice CT colonography has excellent sensitivity and specificity for detection of colorectal lesions 5 mm or greater in size, and the radiation exposure is relatively low. However, before this technique can be generally recommended for colorectal screening, further improvement in the detection of flat and extremely small lesions must be achieved.

Adult↗

Feasibility of MDCT Colonography in ultra-low-dose technique in the detection of colorectal lesions: comparison with high-resolution video colonoscopy.

OBJECTIVE: The purpose of this study was to assess the feasibility of MDCT colonography in an ultra-low-dose technique in the detection of endoluminal colonic lesions compared with high-resolution video colonoscopy. SUBJECTS AND METHODS: After standard bowel cleansing, 137 patients (77 men, 60 women; mean [+/- SD] age, 57.1 +/- 11.3 years) underwent high-resolution video colonoscopy within 2 hr after ultra-low-dose MDCT colonography had been performed. Ultra-low-dose MDCT colonography was performed with patients in the supine position only using 10 mAs (effective weighted CT dose index, 0.94 mGy). After mathematic noise reduction by nonlinear gaussian filter chains, using dedicated software (ECCET), images were analyzed by two blinded observers in simultaneously displayed interactive 2D and 3D modes. Findings of ultra-low-dose MDCT colonography were compared with the results obtained with high-resolution video colonoscopy. RESULTS: Calculated effective doses were 0.7 and 1.2 mSv for men and women, respectively. Ultra-low-dose MDCT colonography detected 84 (62%) of 135 lesions: 11 (78.6%) of 14 large polyps (> 10 mm), 12 (85.7%) of 14 medium polyps (9.9-5 mm), and 61 (57%) of 107 small polyps (< 5 mm). On a patient-by-patient basis, an overall sensitivity of 70.3% with a specificity of 80.8% was calculated. False-positive findings were seen mostly for small lesions (eight medium and 29 small lesions). Two of the three false-negative lesions were retrospectively detected in contrast-enhanced cleansing fluid; one was a flat lipoma not detectable on ultra-low-dose MDCT colonography. CONCLUSION: Despite an effective dose of approximately 1 mSv, MDCT colonography using an ultra-low-dose technique performs as well as MDCT colonography with a standard dose, according to published data. After mathematic noise reduction, 82% of polyps larger than 5 mm can be detected.

Colon↗

Real-time imaging with the sonographic contrast agent SonoVue: differentiation between benign and malignant hepatic lesions.

OBJECTIVE: We investigated the ability of contrast-enhanced sonography with SonoVue (Altana Pharma, Konstanz, Germany), a sulfur hexafluoride microbubble contrast agent, to reveal differences between benign and malignant focal hepatic lesions. METHODS: One hundred twenty-six lesions in 124 patients with focal hepatic lesions detected by B-mode sonography (hepatocellular carcinoma, n = 36; metastasis, n = 25; cholangiocellular carcinoma, n = 1; lymphoma, n = 2; focal nodular hyperplasia, n = 9; adenoma, n = 4; regenerative cirrhotic nodule, n = 13; hemangioma, n = 29; and focal hyposteatosis, n = 7) were examined in a prospective study. After intravenous injection of 2.4 mL of SonoVue, the liver was examined continuously for 3 minutes by low-mechanical index pulse inversion sonography. RESULTS: For the discrimination of malignant versus benign liver lesions, SonoVue-enhanced sonography improved sensitivity from 78% to 100% and specificity from 23% to 92% compared with baseline sonography. Receiver operating characteristic analysis revealed a significant improvement in this discrimination (area under the receiver operating characteristic curve, 0.510 +/- 0.054 [SD] at baseline sonography, 0.998 +/- 0.003 with SonoVue-enhanced sonography; P < .001). The following flow patterns in the early phase were diagnosis specific: early central starlike pattern for focal nodular hyperplasia, peripheral globular-nodular pattern for hemangioma, and diffuse arterial enhancement for malignant lesions. Homogeneous enhancement in the late phase was predictive for benign lesions (P < .001). Conversely, 93% of patients without contrast enhancement in the late phase had malignant lesions (P < .001). CONCLUSIONS: SonoVue-enhanced sonography has greater specificity and sensitivity than baseline sonography for the differentiation of benign and malignant liver lesions.

Aged↗

Differentiation between benign and malignant hepatic lesions: utility of color stimulated acoustic emission with the microbubble contrast agent Levovist.

OBJECTIVE: This study was undertaken to determine whether the examination of color stimulated acoustic emission in the late phase of Levovist (SH U 508A; Schering AG, Berlin, Germany) enhancement is helpful in the discrimination between benign and malignant liver lesions. METHODS: Fifty-six patients with focal hepatic lesions were examined. Diagnosis of the lesions was confirmed by liver biopsy, computed tomography, or scintigraphy. Thirty-one patients had malignant liver lesions: hepatocellular carcinoma (n = 14), cholangiocellular carcinoma (n = 1), metastasis (n = 14), and lymphoma (n = 2). Twenty-five patients had benign lesions: focal nodular hyperplasia (n = 8), hepatic adenoma (n = 1), focal hyposteatosis or hypersteatosis (n = 6), hemangioma (n = 7), and regenerative cirrhotic nodules (n = 3). After a delay of 5 to 10 minutes without scanning, the liver was examined by color stimulated acoustic emission with a fast sweep of 1 to 3 seconds. RESULTS: All patients with homogeneous color stimulated acoustic emission in the late phase of Levovist enhancement had benign liver lesions (P < .001; specificity, 100%; sensitivity, 68%; positive predictive value, 100%; and negative predictive value, 79%). Eighty-one percent of the patients with nonenhancing lesions in the late phase surrounded by enhanced liver parenchyma had malignant liver lesions (P < .001; specificity, 72%; sensitivity, 94%; positive predictive value, 81%; and negative predictive value, 90%). Interobserver agreement (weighted kappa value) improved from 0.570 +/- 0.038 for baseline sonography to 0.918 +/- 0.028 for color stimulated acoustic emission sonography. The area under the receiver operating characteristic curves for color stimulated acoustic emission sonography (0.927) was significantly higher than for baseline sonography (0.739; P < .05). CONCLUSIONS: Color stimulated acoustic emission in the late phase of Levovist enhancement has a high specificity and sensitivity for differentiation between benign and malignant focal liver lesions.

Analysis of Variance↗

[Virtual colonography].

Recent technical developments in computed tomography (CT) and magnetic resonance imaging (MRI) have made a virtual presentation of the colon possible. The results of clinical investigations comparing virtual colonography and conventional colonoscopy up to now are promising. Virtual colonography is a potential tool for colorectal carcinoma screening in the future, but it still has an unsatisfactory sensitivity for the detection of small and flat lesions and exposes the patient to substantial doses of ionizing radiation. Recent investigations using ultra-low-dose (< 2 mSv) multislice CT colonography show promising results. Magnetic resonance (MR) colonography as a radiation-free modality is the technique of the future. Although encouraging results using virtual MR colonography for the detection of colorectal polyps have been reported, the sensitivity of detecting small polyps (</= 10 mm) and flat lesions is poor. Main reason is the limited spatial resolution in MRI of the colon. The potential role of virtual colonography in the prevention of colorectal cancer is not yet clear. Larger studies with asymptomatic persons at average risk are needed, and further improvements in the detection of flat and very small (< 5 mm) lesions need to be achieved before advocating the use of virtual colonography for routine colorectal cancer screening.

Adenoma↗

Late-phase pulse-inversion sonography using the contrast agent levovist: differentiation between benign and malignant focal lesions of the liver.

OBJECTIVE: We assessed the ability of contrast-enhanced sonography to reveal differences between benign and malignant focal hepatic lesions. SUBJECTS AND METHODS: We examined 67 patients with focal hepatic lesions in a prospective study. The causes of the lesions were confirmed by histology, CT, MR imaging, or scintigraphy. The liver was screened for focal lesions using sonography. Thereafter, 2 g of Levovist (300 mg/mL; 1 mL/sec) was injected IV as a bolus. After a delay of at least 2.5 min without scanning, the liver was examined via three different scans using pulse-inversion sonography. RESULTS: For the discrimination of malignant versus benign liver lesions, contrast-enhanced sonography improved sensitivity from 85% to 100% and specificity from 30% to 63%, as compared with baseline sonography. Receiver operating characteristic analysis revealed a significant improvement in this discrimination (A(z) = 0.692 +/- 0.065 at baseline sonography, A(z) = 0.947 +/- 0.037 with contrast-enhanced sonography, p < 0.001). Furthermore, a lower interobserver variability was found for contrast-enhanced sonography (weighted kappa = 0.947), as compared with baseline sonography (weighted kappa = 0.469). All lesions that had homogeneous enhancement in the late phase of Levovist enhancement were benign. In distinction, 90% of lesions without contrast enhancement in the late phase were malignant. All lesions were malignant that were isoechoic (invisible) on baseline sonography but visible because of lack of enhancement after injection. CONCLUSION: Contrast-enhanced sonography has greater specificity and sensitivity than baseline sonography for the differentiation of benign and malignant liver lesions.

Adult↗

Pulse inversion sonography in the early phase of the sonographic contrast agent Levovist: differentiation between benign and malignant focal liver lesions.

OBJECTIVE: To determine whether examination of focal liver lesions by pulse inversion sonography in the early perfusion phase of the contrast agent Levovist (SH U 508A; Schering AG, Berlin, Germany) enables distinction between benign and malignant lesions. METHODS: Seventy-two patients were examined. The cause of the lesion was confirmed by liver biopsy, computed tomography, or both or by hepatic iminodiacetic acid-enhanced scintigraphy. Forty-two patients had malignant liver lesions, and 30 had benign liver lesions. After injection of 2 g of Levovist intravenously, analysis of Levovist arrival was performed by the interval delay imaging technique for 60 seconds. RESULTS: The early arrival of Levovist less than 30 seconds after injection was used as an indicator for malignancy and had specificity of 67% and sensitivity of 60% (P < .05). The central starlike fill-in as a sign for focal nodular hyperplasia had specificity of 100% and sensitivity of 67% (P < .001). The rimlike pattern followed by centripetal fill-in as a sign for hemangioma had specificity of 100% and sensitivity of 18% (P < .01). In contrast, the early diffuse stippled arrival pattern was found in 60% of malignant lesions and also in 33% of cases of focal nodular hyperplasia and in 1 patient with an adenoma. CONCLUSIONS: Analysis of Levovist arrival time cannot distinguish between a malignant or benign lesion in individual cases. However, the central starlike arrival pattern is characteristic of focal nodular hyperplasia.

Aged↗

Serotonin release during percutaneous radiofrequency ablation in a patient with symptomatic liver metastases of a neuroendocrine tumor.

In a patient with symptomatic liver metastases of a neuroendocrine tumor larger than 10 cm in diameter percutaneous radiofrequency ablation was performed. The ablation resulted in a significant decrease in tumor size and a good long-term improvement of symptoms. Plasma serotonin 48 hours after the ablation was approximately 10-fold lower than before. However, sequential determination of plasma serotonin during the radiofrequency ablation revealed a two-fold increase of plasma serotonin induced by the procedure. There was also an approximately three-fold increase of 5-hydroxyindol acetic acid in urine in the 24 hours following the ablation. The data show that ablation procedures in neuroendocrine tumors may induce hormone release which may be critical in patients with severe clinical symptoms.

Catheter Ablation↗