Search PubMed⌕ Search

Biomedical subjects

Christoph Troppmann

Publications and source records attributed to Christoph Troppmann.

21 records · Page 2Linked to original sources

Laparoscopic (vs open) live donor nephrectomy: a UNOS database analysis of early graft function and survival.

The impact of laparoscopic (lap) live donor nephrectomy on early graft function and survival remains controversial. We compared 2734 kidney transplants (tx) from lap donors and 2576 tx from open donors reported to the U.S. United Network for Organ Sharing from 11/1999 to 12/2000. Early function quality (>40 mL urine and/or serum creatinine [creat] decline >25% during the first 24 h post-tx) and delayed function incidence were similar for both groups. Significantly more lap (vs. open) txs, however, had discharge creats greater than 1.4 mg/dL (49.2% vs. 44.9%, p = 0.002) and 2.0 mg/dL (21.8% vs. 19.5%, p = 0.04). But all later creats, early and late rejection, as well as graft survival at 1 year (94.4%, lap tx vs. 94.1%, open tx) were similar for lap and open recipients. Our data suggests that lap nephrectomy is associated with slower early graft function. Rejection rates and short-term graft survival, however, were similar for lap and open graft recipients. Further prospective studies with longer follow up are necessary to assess the potential impact of the laparoscopic procurement mode on early graft function and long-term outcome.

Adult↗

Early and late recipient graft function and donor outcome after laparoscopic vs open adult live donor nephrectomy for pediatric renal transplantation.

BACKGROUND: Laparoscopically procured live donor kidney grafts are increasingly transplanted into pediatric recipients. The safety and efficacy of this changed surgical practice are unknown. HYPOTHESIS: Outcomes of laparoscopic vs open donor grafts in recipients 18 years and younger are equivalent. DESIGN AND SETTING: Retrospective review at an academic tertiary care referral center. PATIENTS: Eleven consecutive pediatric recipients of laparoscopically procured kidneys between April 1, 1997, and December 31, 2001, were pair matched for age with 11 recipients of openly procured kidneys between December 1, 1991, and March 31, 1997; the 22 adult donors were also studied. MAIN OUTCOME MEASURES: Recipients: surgical complications, graft function and survival. Donors: perioperative morbidity and length of hospital stay. RESULTS: Twenty (91%) of 22 kidneys were donated by a parent of the recipient. In recipients of laparoscopically procured grafts, we observed significantly lower creatinine clearances and higher creatinine levels on days 1, 4, and 6, but by 1 month, graft function was similar in both groups. No significant differences in surgical complications, delayed function, acute and chronic rejection, and graft survival rates were found. No laparoscopic or open donor required blood transfusion, reoperation, or hospital readmission. One laparoscopic donor (9%) was converted to open nephrectomy. For laparoscopic vs open donors, median operative time was longer (difference, 67 min; P =.08), but median postoperative length of stay was significantly shorter (3 vs 5 days; P =.02). CONCLUSIONS: Laparoscopic live donor nephrectomy has no adverse impact on pediatric recipient outcomes. For donors, the laparoscopic operation is safe and the hospital stay is shortened. These results support the continued use of laparoscopically procured live donor kidneys in pediatric renal transplantation.

Adolescent↗

Real-time assessment of in vivo renal ischemia using laser autofluorescence imaging.

Potentially transplantable kidneys experience warm ischemia, and this injury is difficult to quantify. We investigate optical spectroscopic methods for evaluating, in real time, warm ischemic kidney injury and reperfusion. Vascular pedicles of rat kidneys are clamped unilaterally for 18 or 85 min, followed by 18 or 35 min of reperfusion, respectively. Contralateral, uninjured kidneys serve as controls. Autofluorescence and cross-polarized light scattering images are acquired every 15 s using 335-nm laser excitation (autofluorescence) and 650+/-20-nm linearly polarized illumination (light scattering). We analyze changes of injured-to-normal kidney autofluorescence intensity ratios during ischemia and reperfusion phases. The effect of excitation with 260 nm is also explored. Average injured-to-normal intensity ratios under 335-nm excitation decrease from 1.0 to 0.78 at 18 min of ischemia, with a return to baseline during 18 min of reperfusion. However, during 85 min of warm ischemia, average intensity ratios level off at 0.65 after 50 min, with no significant change during 35 min of reperfusion. 260-nm excitation results in no autofluorescence changes with ischemia. Cross-polarized light scattering images at 650 nm suggest that changes in hemoglobin absorption are not related to observed temporal behavior of the autofluorescence signal. Real-time detection of kidney tissue changes associated with warm ischemia and reperfusion using laser spectroscopy is feasible. Normalizing autofluorescence changes under 335 nm using the autofluorescence measured under 260-nm excitation may eliminate the need for a control kidney.

Animals↗