Search PubMed⌕ Search

Biomedical subjects

Christoph Cremer

Publications and source records attributed to Christoph Cremer.

24 records · Page 2Linked to original sources

Subwavelength size determination by spatially modulated illumination virtual microscopy.

A new approach for determining the sizes of individual, small fluorescent objects with diameters considerably below the optical resolution limit is described in which spatially modulated illumination (SMI) microscopy and 360-647-nm excitation wavelengths are used. The results of SMI virtual microscopy computer simulations indicate that, in this wavelength range, reliable measurements of sizes as small as approximately 20 nm are feasible if the low numbers of fluorescence photons that are usually detected from such small objects are taken into account. This method is based on the well-known fact that the modulation of the diffraction image in a SMI microscope is disturbed by the size of the object. Using appropriately calculated calibration functions, one can use this disturbance of the modulation to determine the size of the original object.

Journal Article↗

High-resolution colocalization of single dye molecules by fluorescence lifetime imaging microscopy.

Conventional fluorescence microscopy can be used to determine the positions of objects in space when those objects are separated by distances greater than several hundred nanometers, as restricted by the diffraction limit of light. Fluorescence microscopy/spectroscopy based on fluorescence resonance energy-transfer techniques can be used to measure separation distances below approximately 10 nm. To fill the gap between these fundamental limits, we have developed an alternative technique for high-resolution colocalization of fluorescent dyes. The technique is based on fluorescence lifetime imaging. Under favorable conditions, the method can be used to distinguish, and to measure the distance between, two dye molecules that are less than 30 nm apart. To demonstrate the method, lifetime images of a mixture of Cy5 and JF9 (rhodamine derivative) molecules statistically adsorbed on a glass surface were acquired and analyzed. Since these two molecular species differ in fluorescence lifetime (for Cy5, tau(f) = 2.0 ns, and for JF9, tau(f) = 4.0 ns), it is possible to assign the contribution of fluorescence of the two dye types to each image pixel using a pattern recognition technique. Since both dye types can be excited using the same laser wavelength, the measurement is free of chromatic aberrations. The results presented demonstrate the first high-precision distance measurements between single conventional fluorescent dyes based solely on fluorescence lifetime.

Journal Article↗

Spatial preservation of nuclear chromatin architecture during three-dimensional fluorescence in situ hybridization (3D-FISH).

3D-FISH has become a major tool for studying the higher order chromatin organization in the cell nucleus. It is not clear, however, to what extent chromatin arrangement in the nucleus after fixation and 3D-FISH still reflects the order in living cells. To study this question, we compared higher order chromatin arrangements in living cells with those found after the 3D-FISH procedure. For in vivo studies we employed replication labeling of DNA with Cy3-conjugated nucleotides and/or chromatin labeling by GFP-tagged histone 2B. At the light microscope level, we compared the intranuclear distribution of H2B-GFP-tagged chromatin and the positions of replication-labeled chromatin domains in the same individual cells in vivo, after fixation with 4% paraformaldehyde, and after 3D-FISH. Light microscope data demonstrate a high degree of preservation of the spatial arrangement of approximately 1-Mb chromatin domains. Subsequent electron microscope investigations of chromatin structure showed strong alterations in the ultrastructure of the nucleus caused mainly by the heat denaturation step. Through this step chromatin acquires the appearance of a net with mesh size of 50-200 nm roughly corresponding to the average displacement of the chromatin domains observed at light microscope level. We conclude that 3D-FISH is a useful tool to study chromosome territory structure and arrangements down to the level of approximately 1-Mb chromatin domain positions. However, important ultrastructural details of the chromatin architecture are destroyed by the heat denaturation step, thus putting a limit to the usefulness of 3D-FISH analyses at nanometer scales.

Carbocyanines↗

Evolutionary conservation of chromosome territory arrangements in cell nuclei from higher primates.

We demonstrate that the nuclear topological arrangement of chromosome territories (CTs) has been conserved during primate evolution over a period of about 30 million years. Recent evidence shows that the positioning of chromatin in human lymphocyte nuclei is correlated with gene density. For example, human chromosome 19 territories, which contain mainly gene-dense and early replicating chromatin, are located toward the nuclear center, whereas chromosome 18 territories, which consist mainly of gene-poor and later replicating chromatin, is located close to the nuclear border. In this study, we subjected seven different primate species to comparative analysis of the radial distribution pattern of human chromosome 18- and 19-homologous chromatin by three-dimensional fluorescence in situ hybridization. Our data demonstrate that gene-density-correlated radial chromatin arrangements were conserved during higher-primate genome evolution, irrespective of the major karyotypic rearrangements that occurred in different phylogenetic lineages. The evolutionarily conserved positioning of homologous chromosomes or chromosome segments in related species supports evidence for a functionally relevant higher-order chromatin arrangement that is correlated with gene-density.

Animals↗

Spatially modulated illumination microscopy allows axial distance resolution in the nanometer range.

For an improved understanding of the structural basis of cellular mechanisms, it is highly desirable to develop methods for a detailed topological analysis of biological nanostructures and their dynamics in the interior of three-dimensionally conserved cells. We present a method of far-field laser fluorescence microscopy to measure relative axial positions of pointlike fluorescent targets and the distance between each target in the range of a few nanometers. The physical principle behind this approach can be extended to the determination of three-dimensional (3D) positions and 3D distances between any number of objects that can be discriminated owing to their spectral signature, thus allowing topological measurements so far regarded to be beyond the capabilities of light microscopy.

Algorithms↗

Saturated patterned excitation microscopy--a concept for optical resolution improvement.

The resolution of optical microscopy is limited by the numerical aperture and the wavelength of light. Many strategies for improving resolution such as 4Pi and I5M have focused on an increase of the numerical aperture. Other approaches have based resolution improvement in fluorescence microscopy on the establishment of a nonlinear relationship between local excitation light intensity in the sample and in the emitted light. However, despite their innovative character, current techniques such as stimulated emission depletion (STED) and ground-state depletion (GSD) microscopy require complex optical configurations and instrumentation to narrow the point-spread function. We develop the theory of nonlinear patterned excitation microscopy for achieving a substantial improvement in resolution by deliberate saturation of the fluorophore excited state. The postacquisition manipulation of the acquired data is computationally more complex than in STED or GSD, but the experimental requirements are simple. Simulations comparing saturated patterned excitation microscopy with linear patterned excitation microscopy (also referred to in the literature as structured illumination or harmonic excitation light microscopy) and ordinary widefield microscopy are presented and discussed. The effects of photon noise are included in the simulations.

Computer Simulation↗