Christina Unterberg-Buchwald

Publications and source records attributed to Christina Unterberg-Buchwald.

7 recordsLinked to original sources

Improving SVT discrimination in single-chamber ICDs: a new electrogram morphology-based algorithm.

INTRODUCTION: Wide-spread adoption of ICD therapy has focused efforts on improving the quality of life for patients by reducing "inappropriate" shock therapies. To this end, distinguishing supraventricular tachycardia from ventricular tachycardia remains a major challenge for ICDs. More sophisticated discrimination algorithms based on ventricular electrogram morphology have been made practicable by the increased computational ability of modern ICDs. METHODS AND RESULTS: We report results from a large prospective study (1,122 pts) of a new ventricular electrogram morphology tachycardia discrimination algorithm (Wavelet Dynamic Discrimination, Medtronic, Minneapolis, MN, USA) operating at minimal algorithm setting (RV coil-can electrogram, match threshold of 70%). This is a nonrandomized cohort study of ICD patients using the morphology discrimination of the Wavelet algorithm to distinguish SVT and VT/VF. The Wavelet criterion was required ON in all patients and all other supraventricular tachycardia discriminators were required to be OFF. Spontaneous episodes (N = 2,235) eligible for ICD therapy were adjudicated for detection algorithm performance. The generalized estimating equations method was used to remove bias introduced when an individual patient contributes multiple episodes. Inappropriate therapies for supraventricular tachycardia were reduced by 78% (90% CI: 72.8-82.9%) for episodes within the range of rates where Wavelet was programmed to discriminate. Sensitivity for sustained ventricular tachycardia was 98.6% (90% CI: 97-99.3%) without the use of high-rate time out. CONCLUSIONS: Results from this prospective study of the Wavelet electrogram morphology discrimination algorithm operating as the sole discriminator in the ON mode demonstrate that inappropriate therapy for supraventricular tachycardia in a single-chamber ICD can be dramatically reduced compared to rate detection alone.

Algorithms↗

Transfection of the DNA for the receptor KDR/flk-1 attenuates neointimal proliferation and luminal narrowing in a coronary stent angioplasty model.

BACKGROUND: Neointimal proliferation resulting in luminal renarrowing is the major cause of restenosis limiting the long-term success of coronary angioplasty in 20 to 30% of patients. Local transfection of the DNA encoding for VEGF has been shown to enhance re-endothelialization and reduce neointimal proliferation in an experimental model. We tested the hypothesis that transfection of the DNA for the receptor of vascular endothelial growth factor VEGF, KDR-flk-1, reduces neointimal proliferation after angioplasty. METHODS: In a minipig model, we performed coronary stent implantation, followed by injection of either KDR/flk-1 DNA (200 microg of linearized DNA in a CMV-promotor) or LacZ control in two coronary artery segments per animal in a randomized, blinded protocol (n = 22 animals). Expression of KDR/flk-1 was analyzed using in situ hybridization after 4, 7, and 14 days. RESULTS: In KDR-transfected coronary segments, expression of KDR/flk-1 occurred earlier and to much stronger extent compared to LacZ-transfected segments. After 4 weeks (n = 10) neointimal proliferation and luminal narrowing was significantly reduced in KDR/flk-1 transfected animals. No expression of locally transfected DNA was detected in other organs. CONCLUSION: The hypothesis is supported, that expression of the VEGF-receptor KDR/flk-1 can be rate-limiting for endothelial regeneration and that its transient overexpression at the time angioplasty can prevent excessive neointimal proliferation resulting in restenosis.

Angioplasty, Balloon, Coronary↗

Biventricular pacing improves the blunted force-frequency relation present during univentricular pacing in patients with heart failure and conduction delay.

BACKGROUND: In patients with chronic heart failure (CHF) and conduction delay, biventricular (BiV) and left ventricular (LV) pacing similarly improve systolic function at resting heart rates. We hypothesized that BiV and univentricular pacing differentially affect contractile function at increasing heart rates. METHODS AND RESULTS: Twenty-two patients (aged 66+/-2 years, QRS 179+/-8 ms, LV ejection fraction 23+/-1%) underwent cardiac catheterization before device implantation to measure LV hemodynamics at baseline (rate 68+/-2 bpm; sinus rhythm n=18; atrial fibrillation n=4) and during BiV, LV, and right ventricular (RV) stimulation at 80, 100, 120, and 140 bpm. BiV and LV pacing at 80 bpm equally augmented dP/dtmax as compared with baseline and RV pacing (P<0.001). Stimulation rate significantly interacted with the effect of BiV, LV, and RV pacing on LV end-diastolic pressure (LVEDP), systolic pressure (LVSP), and dP/dtmax. Increasing the rate from 80 to 140 bpm enhanced dP/dtmax from 913+/-28 to 1119+/-50 mm Hg/s during BiV stimulation (P<0.001) but had no significant effect on contractility during single-site LV (951+/-47 versus 1002+/-54 mm Hg/s) or RV (800+/-46 versus 881+/-49 mm Hg/s) pacing. At 140 bpm, LVEDP was lower and LVSP higher during BiV pacing than during RV and LV pacing (LVEDP 12+/-1 versus 17+/-1 and 16+/-1 mm Hg, P<0.001; LVSP 112+/-5 versus 106+/-5 and 108+/-6 mm Hg, P<0.01 and P=0.09; BiV versus RV and LV pacing, respectively). CONCLUSIONS: Different modes of ventricular stimulation alter the in vivo force-frequency relation of CHF patients. In contrast to single-site LV and RV pacing, contractile function improves with increasing heart rates during BiV stimulation. This effect may contribute to the enhanced exercise capacity during BiV pacing and could provide a functional benefit over LV-only pacing in patients for whom resynchronization therapy is indicated.

Adult↗

Patient Alert to detect ICD lead failure: efficacy, limitations, and implications for future algorithms.

AIMS: An algorithm that alerts implantable cardioverter-defibrillator (ICD) patients, in case of abnormal lead impedance (Patient Alerttrade mark, Medtronic), may help to recognize lead dysfunction. We aimed to determine the utility of Patient Alert for ICD lead-failure detection in a prospective study. METHODS AND RESULTS: Three hundred and sixty ICD patients were followed for 22+/-14 months. Patient Alert was active for pacing impedance <200 and >2000-3000 Omega, and high-voltage conductor impedance <10-20 and >200 Omega. Ten alert events and a total of 29 severe system complications occurred. Patient Alert detected three of 10 ICD lead failures, with a positive predictive value (PPV) of 77.8% for any severe system complication. Retrospective analysis identified 23 patients with a sensing integrity counter (SIC) >300 and revealed an additional four prior undetected lead defects. SIC detected ICD lead failure with 92.9% sensitivity and a PPV of 59.1%. Eight of nine patients with a false-positive SIC had an integrated bipolar lead. Patient Alert combined with SIC detected all ICD lead failures and 71.4% of all severe lead complications. CONCLUSIONS: Patient Alert, based on daily lead-impedance measurement, detected one-third of all ICD lead failures. Combined use with continuous lead integrity monitoring (SIC) increased sensitivity to 100%. Integrated bipolar leads may yield a false-positive SIC. Incorporating SIC and automated pace/sense threshold measurement may improve Patient Alert sensitivity for severe lead complications.

Aged↗

Atrial overdrive pacing in patients with sleep apnea with implanted pacemaker.

RATIONALE: Atrial overdrive pacing markedly improved sleep-disordered breathing in a recent study. OBJECTIVES: Using a single-blind, randomized, crossover design, we aimed to reproduce these findings and investigate the possible underlying mechanisms. METHODS: Twenty ambulatory patients with an implanted pacemaker or cardioverter defibrillator were studied by polysomnography on 3 consecutive nights in a randomized, single-blind, crossover study in which devices were programmed for nonpacing or for overdrive pacing at 7 or 15 beats/minute faster than the mean nocturnal heart rate. Ventilation and biomarkers (urinary norepinephrine excretion, amino-terminal portion of the precursor of brain natriuretic peptide, or NT-proBNP, were also evaluated. MEASUREMENTS AND MAIN RESULTS: Neither the primary endpoint apnea-hypopnea index, nor the apnea index, oxygen desaturation, ventilation, or biomarkers were affected by the nocturnal atrial overdrive pacing. A small, clinically insignificant, rate-dependent reduction in the hypopnea index was evoked by pacing (nonpacing, 13.4 +/- 1.4; pacing 7, 12.9 +/- 1.4; pacing 15, 10.9 +/- 1.0; p < 0.01, analysis of variance). CONCLUSIONS: The lack of effect on the apnea-hypopnea index means that atrial overdrive pacing is inappropriate for treating sleep-disordered breathing.

Aged↗

A new endocardial "over-the-wire" or stylet-driven left ventricular lead: first clinical experience.

Transvenous left ventricular (LV) leads are primarily inserted "over-the-wire" (OTW). However, a stylet-driven (SD) approach may be a helpful alternative. A new polyurethane-coated, unipolar LV lead can be placed either by a stylet or a guide wire, which can be inserted into the lead body from both ends. The multicenter OVID study evaluates the clinical performance of this new steroid- and nonsteroid eluting lead. The primary endpoint is the LV lead implant success rate after identification of the coronary sinus (CS). Secondary endpoints include complication rate, short- and long-term lead characteristics, overall procedure and LV lead placement duration, total fluoroscopy time, and lead handling characteristics ratings. To date, 96 patients with heart failure (68 +/- 9 years old, 76% men) are enrolled. The CS was identified in 95 patients and, in 85 (88.5%), the LV lead was successfully implanted. The final lead positioning was lateral in 41%, posterolateral in 35%, anterolateral in 18%, and great cardiac vein in 6% of patients. In 70%, the 85 successful implantations, both stylet-driven and guide-wire techniques were used, a stylet only was used in 22%, and a guide wire only in 8%. Mean overall duration of 85 successful procedures was 112 +/- 40 minutes, total fluoroscopy time 28 +/- 15 minutes, and the duration of LV lead placement was 35 +/- 29 minutes. During a 3-month follow-up, the loss of LV capture occurred in three and phrenic nerve stimulation in six patients. The mean long-term pacing threshold is 0.8 V/0.5 ms and pacing impedance is 550 Omega. The OVID data suggest that these new leads are safe and effective. The choice of both OTW and SD techniques during lead implantation offers greater procedural flexibility.

Adult↗

Safety and efficacy of advanced atrial pacing therapies for atrial tachyarrhythmias in patients with a new implantable dual chamber cardioverter-defibrillator.

OBJECTIVES: This study evaluated the safety and efficacy of atrial pacing therapies for the treatment and prevention of atrial tachycardia (AT) or atrial fibrillation (AF) in a new dual chamber implantable cardioverter defibrillator (ICD). BACKGROUND: Patients with an ICD may also experience AT or AF that is amenable to pace termination. METHODS: The efficacy of atrial antitachycardia pacing (ATP) therapies for atrial tachycardia or atrial fibrillation (AT/AF) was determined in 151 patients after implantation of a GEM III AT ICD (Medtronic Inc., Minneapolis, Minnesota). The percentage of episodes successfully terminated was adjusted for multiple episodes per patient. RESULTS: A total of 717 of 728 (96%) episodes classified as AT or AF were judged to be appropriate detections. By device classification, atrial ATP terminated 187 of 383 (40% adjusted) episodes classified as AT compared with 65 of 240 episodes classified as AF (26% adjusted, p = 0.013). Atrial Ramp or Burst+ ATP terminated 184 of 378 episodes of AT (39% adjusted), whereas 50-Hz Burst pacing therapy terminated only 12 of 109 episodes of AT (12% adjusted) and 65 of 240 episodes of AF (26% adjusted). If efficacy was defined as termination of AT/AF within 20 s of delivery of the pacing therapy, ATP therapies terminated 139 of 383 (32% adjusted) episodes of AT compared with 34 of 240 episodes of AF (15% adjusted, p = 0.003). Efficacy was dependent on AT cycle length. Frequent transitions between AT and AF predicted inefficacy of atrial ATP (p < 0.001). Ventricular proarrhythmia secondary to atrial ATP was not observed. CONCLUSIONS: Atrial ATP therapies terminate many episodes of AT without ventricular proarrhythmia. The addition of 50-Hz Burst pacing has minimal efficacy for AT/AF.

Aged↗