Search PubMed⌕ Search

Biomedical subjects

Christiane K Kuhl

Publications and source records attributed to Christiane K Kuhl.

At least 19 recordsLinked to original sources

Intra-individual comparison of image contrast in SPIO-enhanced liver MRI at 1.5T and 3.0T.

The purpose of the study was to examine if the higher susceptibility at 3.0 Tesla (T) compared to 1.5 T will affect the contrast in MR imaging of the liver after application of superparamagnetic iron oxide particles (SPIO). The study was approved by our institutional review board and informed consent was obtained. Seventeen healthy volunteers were examined in a prospective, intra-individual comparative study within one day on a 1.5 T and a 3.0 T MRI system. T2 weighted TSE sequences were acquired after bolus injection of a SPIO contrast agent. Image contrast and signal to noise ratio (SNR) were compared between the field strengths. Image contrast was calculated between the liver tissue and the kidneys / spleen / muscles and fluids. The students'T-test was used for statistical analysis. No influence of the higher field strength could be observed on image contrast except for the liver / muscle contrast. This was due to a distinct SNR increase of the muscle tissue at 3.0 T as a result of their relaxation properties. The higher susceptibility at 3.0 T compared to 1.5 T does not translate into a stronger signal attenuation of the SPIO enhanced liver parenchyma.

Adult↗

Female pelvis: MR imaging at 3.0 T with sensitivity encoding and flip-angle sweep technique.

This study had institutional review board approval; all 33 patients (mean age, 47 years +/- 16 [standard deviation]) gave informed consent. The aim was to prospectively evaluate the diagnostic image quality yielded by a 3.0-T T2-weighted turbo spin-echo magnetic resonance imaging sequence with a very short imaging time versus that yielded by a standard 3.0-T sequence at imaging of the female pelvis. Signal-to-noise ratio and delineation of gynecologic disorders were approximately equal between the two sequences. The majority of tissue contrasts were comparable, but contrast between fluid and muscle was significantly higher and motion artifacts were reduced (P < .001 for both) with the short imaging time sequence. The fast sequence maintained or improved image quality and thus seems to be advantageous for uncooperative patients.

Adolescent↗

High-field-strength MR imaging of the liver at 3.0 T: intraindividual comparative study with MR imaging at 1.5 T.

PURPOSE: To prospectively evaluate whether magnetic resonance (MR) imaging of the liver at 3.0 T is comparable to that at 1.5 T with respect to image artifacts, image quality, and diagnostic utility in terms of detection and characterization of focal liver lesions in patients with these lesions. MATERIALS AND METHODS: Patients provided informed consent after the study had been explained, and the institutional review board approved the study protocol. An intraindividual comparative study was performed in 21 patients (12 men and nine women; mean age, 58.7 years; range, 36-76 years) with a total of 79 focal liver lesions (benign and malignant) who were examined at 1.5- and 3.0-T MR imaging within 1 week. The imaging protocol consisted of T2-weighted turbo spin-echo (SE) sequences with or without fat suppression, as well as T1-weighted gradient-echo (GRE) sequences with or without gadolinium-based contrast agent. All images were rated independently by two radiologists with respect to types of artifacts (susceptibility, motion, pulsation, image homogeneity, and electrodynamic effects) and in regard to detectability and characterization of focal liver lesions. A modified sign test was used for statistical analysis (alpha < .2). RESULTS: Motion artifacts were significantly more pronounced in non-fat-suppressed T2-weighted turbo SE images at 3.0 T (P = .03), whereas pulsation artifacts were more pronounced (P = .19) in precontrast T1-weighted GRE 1.5-T images. No statistically significant differences (P < .2) were observed for the remaining artifacts and sequences. Of the 79 index lesions, a total of 76 were prospectively identified at 1.5-T imaging and a total of 77 were identified at 3.0-T imaging. CONCLUSION: MR imaging of the liver at 3.0 T, compared with that at 1.5 T, is feasible with equivalent image quality and diagnostic utility in terms of detection and characterization of focal liver lesions.

Adult↗

The management of lobular carcinoma in situ (LCIS). Is LCIS the same as ductal carcinoma in situ (DCIS)?

Lobular carcinoma in situ was first described over 60 years ago. Despite the long history, it continues to pose significant difficulties in screening, diagnosis, management and treatment. This is partly due its multi-focal and bilateral presentation, an incomplete understanding of its biology and natural history and perpetuation of misconceptions gathered over the last decades. In this review, the working group on behalf of EUSOMA has attempted to summarise the current thinking and management of this interesting lesion.

Adult↗

Adverse events after unenhanced and monomeric and dimeric contrast-enhanced CT: a prospective randomized controlled trial.

PURPOSE: To prospectively evaluate adverse events (AEs) in patients who underwent nonionic monomeric or dimeric contrast media-enhanced computed tomography (CT) and to compare these effects with AEs in patients who underwent unenhanced CT. MATERIALS AND METHODS: Local ethics committee approval and written informed consent were obtained. Patients were randomly assigned to the dimeric group, monomeric group, or concurrent control group. Acute (occurring during or within 1 hour after contrast agent injection) and delayed (occurring between 1 hour and 7 days after contrast agent injection) AEs were evaluated and categorized (mild, not requiring treatment; moderate, self-limiting AE requiring simple treatment; severe, AE requiring extensive treatment or endangering life). The two-sided Fisher exact test and the Mann-Whitney U and Wilcoxon signed rank tests were used for statistical analysis. RESULTS: A total of 895 patients were recruited. Acute AEs were noted significantly (P < .05) more often in the monomeric group (44.8% [133 of 297 patients]) than in the dimeric (23.7% [71 of 300 patients]) or control (9.4% [28 of 298 patients]) groups. Two moderate acute AEs were noted in one patient in each contrast agent group; all other acute AEs were mild. There was no significant difference in the overall incidence of delayed AEs between the dimeric and monomeric groups (53.1% [139 of 262 patients] vs 50.8% [131 of 258 patients]). Delayed cutaneous AEs were noted significantly (P < .05) more often in the dimeric group. A total 16 AEs (2.0%) were moderate; no AE was severe. CONCLUSION: The dimeric contrast agent caused fewer acute AEs than the monomeric contrast agent; however, the dimeric and monomeric agents caused a similar overall number of delayed AEs. Delayed cutaneous symptoms were noted more often with the dimeric contrast agent. Both contrast agents were safe in that no severe AEs and only a few moderate AEs were observed.

Adult↗

Contrast-enhanced MR imaging of the breast at 3.0 and 1.5 T in the same patients: initial experience.

PURPOSE: To establish a pulse sequence for dynamic contrast material-enhanced magnetic resonance (MR) imaging of the breast at 3.0 T and to prospectively compare MR imaging at 3.0 T with MR imaging at 1.5 T in the same patients. MATERIALS AND METHODS: A prospective intraindividual internal review board-approved study was performed in 37 women with 53 lesions (25 breast cancers, 28 benign focal lesions) who underwent contrast-enhanced dynamic bilateral subtraction MR imaging twice, once at 1.5 T with a standard technique (voxel size, 1.44 mm3) and once at 3.0 T (voxel size, 0.45-0.72 mm3) with variable repetition time and flip angle settings. Written informed consent was obtained. Sagittal single breast high-spatial-resolution MR imaging was performed with active fat suppression. Image quality, number and features of enhancing lesions, and Breast Imaging Reporting and Data System categories were compared by using the Wilcoxon matched-pairs signed rank test and Student t test for matched pairs. Diagnostic confidence was compared by using a receiver operating characteristic (ROC) analysis. RESULTS: With repetition time prolonged to account for longer T1 relaxation times at 3.0 T and a flip angle of 60 degrees, enhancement rates at 3.0 T were substantially below those at 1.5 T. In two patients with benign lesions, enhancement was rated as insufficient to establish diagnosis. When parameter settings were kept equivalent, equivalent enhancement rates were observed with both systems. With these settings, 3.0-T MR imaging yielded homogeneous signal intensity over the entire field of view. No dielectric resonance effects were observed. Overall image quality scores for the dynamic series were slightly higher at 3.0 T (P<.01). A total of 49 lesions were prospectively identified with both systems. Owing to substantial patient motion at 1.5 T, two malignant lesions in one patient were visualized at 3.0 T only. At 3.0 T, differential diagnosis of enhancing lesions was possible with higher diagnostic confidence, as reflected by a larger area under the ROC curve (P<.05). CONCLUSION: Initial experiences indicate that contrast-enhanced MR imaging at 3.0 T is nearing readiness for clinical use.

Adult↗

Concepts for differential diagnosis in breast MR imaging.

There is broad agreement in that breast MR imaging, compared with all other contemporary breast imaging techniques, offers the highest sensitivity for primary and recurrent invasive breast cancer. For a long time, however, the modality suffered from the reputation of offering only a limited specificity. In addition, the allegedly low sensitivity for intraductal breast cancer hampered the more widespread use of breast MR imaging. More recent results, however, suggest that the specificity and positive predictive value of breast MR imaging are at least equivalent to those of mammography and that the sensitivity for ductal carcinoma in situ (DCIS) is at least comparable to mammography, if not higher. Apart from increasing reader experience, this progress is mainly attributable to the fact that in parallel with improved MR imaging technology, more refined interpretation criteria became available. These criteria allow a substantially improved diagnosis of malignant masses and of DCIS. This article provides an overview on the current status of the diagnosis criteria that are used for differential diagnosis in breast MR imaging and on the diagnostic accuracy that is achievable with breast MR imaging.

Biopsy↗

MR imaging for surveillance of women at high familial risk for breast cancer.

The adequate management of individuals who carry a high lifetime risk for breast cancer is still an unsettled issue. This holds especially true for subjects with documented or suspected germline mutation of a breast cancer susceptibility gene. These women face a lifetime risk for breast cancer of up to 80%, which is, of course, significant. Still, this means that approximately one fifth of women never develop the disease. The perceived mutilating effects of preventive mastectomy make the decision for surgical prevention difficult for most women. Secondary prevention aims at identifying familial breast cancer at the earliest possible stage. During recent years, considerable evidence has been accumulated that breast MR imaging is substantially more sensitive than mammography and breast ultrasound regarding the identification of familial breast cancer. It should be considered an integral part of a surveillance program for women at increased familial risk for breast cancer, be it with or without documented mutation of a breast cancer susceptibility gene.

Age Factors↗

3.0 T neuroimaging: technical considerations and clinical applications.

Since approval by the US Food and Drug Administration (FDA) in 2000, human MR imaging at field strength up to 4.0 T in clinical practice and up to 8.0 T on research systems has become available. Although human MR imaging at field strengths greater than 1.5 T was performed even before 1999 on research systems, the FDA approval for clinical use and the advent of actively shielded magnets marked a new trend for MR vendors and users. Because of the potential technical benefits when moving from 1.5 T to 3.0 T, the number of 3.0 T installations is increasing continuously worldwide. This article reviews the benefits, challenges, and the current knowledge of 3.0 T whole body MR imaging and summarizes its clinical applications.

Adult↗

Diagnostic architectural and dynamic features at breast MR imaging: multicenter study.

PURPOSE: To prospectively determine the prevalence and predictive value of three-dimensional (3D) and dynamic breast magnetic resonance (MR) imaging and contrast material kinetic features alone and as part of predictive diagnostic models. MATERIALS AND METHODS: The study protocol was approved by the institutional review board or ethics committees of all participating institutions, and informed consent was obtained from all participants. Although study data collection was performed before HIPAA went into effect, standards that would be compliant with HIPAA were adhered to. Data from the International Breast MR Consortium trial 6883 were used in the analysis. Women underwent 3D (minimum spatial resolution, 0.7 x 1.4 x 3 mm; minimal temporal resolution, 4 minutes) and dynamic two-dimensional (temporal resolution, 15 seconds) MR imaging examinations. Readers rated enhancement shape, enhancement distribution, border architecture, enhancement intensity, presence of rim enhancement or internal septations, and the shape of the contrast material kinetic curve. Regression was performed for each feature individually and after adjustment for associated mammographic findings. Multivariate models were also constructed from multiple architectural and dynamic features. Areas under the receiver operating characteristic curve (Az values) were estimated for all models. RESULTS: There were 995 lesions in 854 women (mean age, 53 years +/- 12 [standard deviation]; range, 18-80 years) for whom pathology data were available. The absence of enhancement was associated with an 88% negative predictive value for cancer. Qualitative characterization of the dynamic enhancement pattern was associated with an Az value of 0.66 across all lesion architectures. Focal mass margins (Az = 0.76) and signal intensity (Az = 0.70) were highly predictive imaging features. Multivariate models were constructed with an Az value of 0.880. CONCLUSION: Architectural and dynamic features are important in breast MR imaging interpretation. Multivariate models involving feature assessment have a diagnostic accuracy superior to that of qualitative characterization of the dynamic enhancement pattern.

Adolescent↗

Dynamic contrast-enhanced breast MR imaging in men: preliminary results.

PURPOSE: To prospectively evaluate whether the descriptors of lesion features and the diagnostic criteria that have been established for breast magnetic resonance (MR) imaging in female patients may be used for differential diagnosis with breast MR imaging in male patients as well. MATERIALS AND METHODS: The study design was approved by the institutional review board; all patients gave informed consent. The Institutional Review Board and informed consent information applied to the prospective and any retrospective component of the study. Seventeen consecutive male patients (mean age, 53 years +/- 14) were referred for imaging of a palpable breast mass. In addition to mammography and high-frequency breast ultrasonography, patients underwent dynamic breast MR imaging in a prone position with a dedicated double-breast surface coil. The standardized protocol consisted of a T2-weighted turbo spin-echo sequence followed by a dynamic series. Findings were recorded by using the terminology and descriptors and by evaluating the diagnostic criteria (related to morphology and enhancement kinetics) that have been developed for breast MR imaging in female patients. Validation was achieved at biopsy (nine patients) or follow-up with clinical examination and conventional imaging (eight patients). Because of the small size of the patient cohort, statistical significance was not tested. RESULTS: A total of 24 breast abnormalities were diagnosed. Three patients had invasive breast cancer (five tumors), 11 had gynecomastia (six unilateral, five bilateral), two had pseudogynecomastia, and one had a benign solid tumor (angiolipoma). All malignant tumors appeared as irregular masses with heterogeneous internal architecture or rim enhancement and showed rapid initial enhancement (mean value, 137% +/- 23) followed by a washout time course (Breast Imaging Reporting and Data System [BI-RADS] category 5). Diffuse and nodular gynecomastia showed slow initial and persistent enhancement with normal-appearing parenchymal architecture (BI-RADS category 2; 15 of 16 breasts in 10 of 11 patients). In one patient with biopsy-proved bilateral gynecomastia, an area with segmental enhancement was classified as suspicious for ductal carcinoma in situ. Pseudogynecomastia did not enhance at all. The angiolipoma showed benign morphologic features and slow initial and persistent enhancement (BI-RADS category 2). CONCLUSION: In the small study cohort, the MR imaging features of benign breast diseases and breast cancers in male patients seemed to be comparable to those seen in female patients.

Adult↗

Mammography, breast ultrasound, and magnetic resonance imaging for surveillance of women at high familial risk for breast cancer.

PURPOSE: To compare the effectiveness of mammography, breast ultrasound, and magnetic resonance imaging (MRI) for surveillance of women at increased familial risk for breast cancer (lifetime risk of 20% or more). PATIENTS AND METHODS: We conducted a surveillance cohort study of 529 asymptomatic women who, based on their family history and/or mutational analysis, were suspected or proven to carry a breast cancer susceptibility gene (BRCA). A total of 1,542 annual surveillance rounds were completed with a mean follow-up of 5.3 years. Diagnostic accuracies of the three imaging modalities used alone or in different combinations were compared. RESULTS: Forty-three breast cancers were identified in the total cohort (34 invasive, nine ductal carcinoma-in-situ). Overall sensitivity of diagnostic imaging was 93% (40 of 43 breast cancers); overall node-positive rate was 16%, and one interval cancer occurred (one of 43 cancers, or 2%). In the analysis by modality, sensitivity was low for mammography (33%) and ultrasound (40%) or the combination of both (49%). MRI offered a significantly higher sensitivity (91%). The sensitivity of mammography in the higher risk groups was 25%, compared with 100% for MRI. Specificity of MRI (97.2%) was equivalent to that of mammography (96.8%). CONCLUSION: Mammography alone, and also mammography combined with breast ultrasound, seems insufficient for early diagnosis of breast cancer in women who are at increased familial risk with or without documented BRCA mutation. If MRI is used for surveillance, diagnosis of intraductal and invasive familial or hereditary cancer is achieved with a significantly higher sensitivity and at a more favorable stage.

Adult↗

Brain tumors: full- and half-dose contrast-enhanced MR imaging at 3.0 T compared with 1.5 T--Initial Experience.

PURPOSE: To prospectively and intraindividually compare the effect of magnetic resonance (MR) imaging at a higher magnetic field strength (3.0 T) on contrast-to-noise ratio (CNR) at different doses of a T1-shortening contrast agent in patients with contrast-enhancing brain lesions, with 1.5-T MR imaging as a reference standard. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained for all patient and volunteer studies. Twelve patients (six women, six men; mean age, 58 years; range, 29-76 years) with 12 enhancing brain lesions (11 patients with primary brain tumors and one with a solitary cerebral metastasis) underwent contrast material-enhanced MR imaging three times, on three separate days: once at 1.5 T with a full dose of 0.10 mmol/kg gadopentetate dimeglumine, once at 3.0 T with a full dose, and once at 3.0 T with half that dose, 0.05 mmol/kg. The same contrast-enhanced T1-weighted spin-echo images (repetition time msec/echo time msec, 500/12; section thickness, 5 mm; matrix, 256 x 205) were obtained at both 3.0 T and 1.5 T after prior optimization of parameters at 3.0 T. The number and conspicuity of enhancing brain lesions were assessed with blinded clinical image reading. Signal-to-noise ratio and CNR were determined with region of interest analysis of enhancing lesions and normal contralateral white matter. For 3.0 T with half the standard dose and with the full dose, CNR of lesions was intraindividually compared with CNR at 1.5 T with the full dose by using the Wilcoxon matched-pairs signed rank test. RESULTS: At 3.0 T and full dose, CNR was 2.8-fold higher than that at 1.5 T and full dose (P < .001). At the same time, higher lesion conspicuity at clinical image reading was observed. With only half the standard dose, MR imaging at 3.0 T still yielded higher CNR (1.3-fold higher) than that with full dose at 1.5 T (P < .01). CONCLUSION: With the same amount of contrast agent, MR imaging at 3.0 T offered a significantly higher CNR of enhancing cerebral lesions, compared with that at 1.5 T; even with the dose reduced by half, CNR was still higher at 3.0 T.

Adult↗

MRI detection of distinct incidental cancer in women with primary breast cancer studied in IBMC 6883.

BACKGROUND: Prior single institution studies suggest MRI may improve the assessment of the extent of cancer within the breast, and thus reduce the risk of leaving macroscopic disease in the breast following breast conservation therapy. We report on the rate of MRI and mammography detection of foci of distinct incidental cancer in a prospective, multi center trial involving 426 women with confirmed breast cancer at 15 institutions in the US, Canada, and Germany. METHODS: Women underwent mammography and MRI prior to biopsy of the suspicious index lesion. Additional incidental lesions (IL) greater than 2 cm from the index lesion that were detected by mammography and MRI were noted and characterized. Biopsy recommendations were associated with ILs given an assessment of suspicious or highly suspicous (BiRads 4 and 5). These assessments were considered a positive test. RESULTS: MRI had a significantly higher yield of confirmed cancer ILs than mammography (0.18 (95%CI: 0.142-0.214) for MRI versus 0.072 (95%CI: 0.050-0.100) for mammography). The cancer ILs detected by MRI alone appeared to be similar to those detected by mammography with respect to size and histology. The percentage of biopsies of ILs that resulted in a cancer diagnosis was similar between the modalities (MRI 0.72(95%CI: 0.6-0.81); Mammography 0.85 (95%CI: 0.62-0.96)). CONCLUSIONS: These results suggest that consideration needs to be given regarding the integration of breast MRI into the pretreatment evaluation of women seeking breast conservation therapy.

Biopsy↗

Three-dimensional dynamic susceptibility-weighted perfusion MR imaging at 3.0 T: feasibility and contrast agent dose.

PURPOSE: To prospectively investigate if T2*-weighted dynamic susceptibility-weighted first-pass perfusion magnetic resonance (MR) imaging is feasible at 3.0 T and which dose of contrast agent is suitable for high-field-strength imaging. MATERIALS AND METHODS: Informed consent was obtained from all participants; study protocol was approved by the institutional review board. Study included three volunteers (two men, one woman aged 35, 39, and 52 years) and 26 patients (mean age, 49 years +/- 12.8 [standard deviation]; range, 19-76 years). Volunteers underwent 3.0-T perfusion MR imaging with 0.20, 0.10, and 0.05 mmol per kilogram body weight of gadopentetate dimeglumine; patients underwent imaging with 0.10- and 0.05-mmol doses. Perfusion MR imaging was performed with three-dimensional echo-shifted echo-planar imaging (repetition time msec/echo time msec, 14/21; isotropic 4 mm3 voxels; 50 dynamic volumes with 30 sections each, covering entire brain at temporal resolution of 1.5 seconds per MR image). Quality of source echo-planar images and perfusion maps was assessed; perfusion maps obtained at studies with different contrast media doses were compared. Quantitative perfusion values and diagnostic sensitivity of perfusion studies with 0.10-mmol dose were compared with results with 0.05-mmol dose. Image quality scores were compared with marginal homogeneity test for multinomial variables (Mantel-Haenszel statistics for ordered categorized values). Signal-to-noise ratio and baseline signal intensity in perfusion studies were tested (Student t test for paired samples). Mean transit time (MTT), negative integral (NI), and maximum T2* effect from region-of-interest analysis were compared (one-tailed Student t test for paired samples). Quantitative data on number of gamma-fitted pixels were compared (t test for paired samples). Difference with P=.05 (t test for paired samples) was considered significant. RESULTS: Perfusion image quality was satisfactory even in areas close to skull base (47 of 52 images, minor distortions; remaining images, marked distortions). Perfusion imaging with 0.20-mmol dose caused almost complete signal cancellation during first pass, particularly in cortical gray matter, since mean maximum T2* effect of 98%, 99%, and 98% for gray matter was reached such that the accurate calculation of perfusion maps was impossible. With 0.10-mmol dose, the NI and maximum T2* effect were comparable to published data for 1.5-T perfusion imaging with 0.20- and 0.05-mmol doses; perfusion maps of sufficient diagnostic quality were obtained. For gray matter, mean maximum T2* effect was 25.4% +/- 9.8 with 0.10-mmol dose and 17.5% +/- 9.0 with 0.05-mmol dose. For white matter, mean maximum T2* effect was 15.2% +/- 4.5 with 0.10-mmol dose and 7.7% +/- 2.9 with 0.05-mmol dose. Difference in maximum signal intensity decrease was significant (P <.01). For NI, the difference between 0.10- and 0.05-mmol doses was significant: For gray matter, mean NI was 3.1 +/- 1.60 for 0.10-mmol dose and 1.56 +/- 1.16 for 0.05-mmol dose. For white matter, mean NI was 1.35 +/- 0.59 with 0.1-mmol dose and 0.59 +/- 0.30 with 0.05-mmol dose. CONCLUSION: With echo-shifted multishot echo-planar imaging, dynamic susceptibility-weighted perfusion MR imaging at high field strength is feasible without relevant image distortions. Compared with contrast agent dose for 1.5 T imaging, the dose for 3.0 T can be reduced to 0.10 mmol.

Adult↗

Functional 3.0-T MR assessment of higher cognitive function: are there advantages over 1.5-T imaging?

PURPOSE: To compare cortical activation patterns associated with manual motor decision tasks at 1.5- and 3.0-T functional magnetic resonance (MR) imaging. MATERIALS AND METHODS: The local ethics committee approved this study, and informed written consent was obtained. Ten right-handed healthy volunteers (eight men and two women; mean age, 35 years +/- 7 [standard deviation]) underwent functional MR imaging twice, once at 1.5 T and once at 3.0 T, while performing cognitive tasks that demanded manual motor decisions (letter-finger matching and lexical and semantic decisions). While stimulus presentation was blocked, an event-related model was employed to analyze subjects' individual responses. A group analysis of functional data was performed with a t test of 1.5- and 3.0-T results in the 10 subjects. RESULTS: Manual motor decisions activated a widespread network of motor- (primary motor, posterior parietal) and decision-related areas (superior frontal cortex or anterior cingulate) at both field strengths (P <.05, corrected). Moreover, additional functional activation was detected in medial (supplementary motor area) and dorsal premotor regions (P <.05, corrected) at 3.0-T functional MR imaging, which was not detectable with corresponding 1.5-T imaging. The mean t value for peak voxels in activated areas detectable with both systems was 1.3 times larger at 3.0 T than that at 1.5 T. CONCLUSION: Functional 3.0-T MR imaging allows detection of additional activation in cortical areas involved in higher executive motor functions compared with functional 1.5-T MR imaging.

Adult↗

Sensitivity encoding (SENSE) for contrast-enhanced 3D MR angiography of the abdominal arteries.

PURPOSE: To assess sensitivity encoding (SENSE) for contrast-enhanced MR angiography (CE-MRA) of the abdominal arteries in comparison with standard MRA protocols. MATERIALS AND METHODS: In 22 patients MRA of the abdominal arteries was performed twice (once using a standard protocol, and once with the additional use of SENSE). In 10 patients all examination parameters were kept constant (TR/TE/FA = 3.8 msec/1.3 msec/30 degrees ), and a reduction in scan time from 22 to 11 seconds was realized with the use of SENSE. In 12 patients, using SENSE the acquisition matrix was increased from 208 to 416, keeping the scan time constant. Image quality was scored on a five-point scale by three radiologists. Additionally, ROI-based measurements of CNR were performed. RESULTS: For both protocols, image quality was significantly improved using SENSE. The time-reducing SENSE protocol yielded an average score of 4.2 points vs. 3.1 for the standard protocol. Using SENSE to increase the acquisition matrix, an average score of 4.3 was reached vs. 3.2 for the standard protocol (P < 0.05). The number of depictable small vessels and their bifurcations was significantly increased by either of the two SENSE protocols as compared to the standard imaging procedure. CONCLUSION: SENSE for MRA of the abdominal arteries significantly increases image quality and permits a substantial reduction in breath-hold time or a significantly improved spatial resolution.

Abdomen↗

Sensitivity encoding for diffusion-weighted MR imaging at 3.0 T: intraindividual comparative study.

PURPOSE: To prospectively evaluate whether diffusion-weighted (DW) magnetic resonance (MR) imaging with sensitivity encoding (SENSE) at 3.0 T can help to improve image quality and confidence in and accuracy of diagnosis of ischemic lesions, compared with DW MR imaging with conventional phase encoding, in patients. MATERIALS AND METHODS: Patients provided informed consent after the study had been explained, and the institutional review board approved the study protocol. Eighty-five patients (46 male and 39 female patients; age range, 13-86 years; mean age, 52 years) underwent single-shot spin-echo echo-planar DW MR imaging at 3.0 T twice, in a randomized order: once with conventional phase encoding (repetition time msec/echo time msec, 4283/79) and once with SENSE (3141/69, with a reduction factor of three). With both, 128 x 128 matrix, 24 4-mm-thick sections, and two b values of 0 and 1000 sec/mm(2) were used. An eight-element SENSE-compatible receive-only surface coil was used; the built-in body coil served for radiofrequency transmission and generation of the coil sensitivity profile. SENSE and conventional phase encoding were compared for image quality, signal-to-noise ratio, relative signal intensity (SI), and lesion contrast. Two neuroradiologists read images. Diagnostic accuracy of and confidence in detection of apparent diffusion coefficient (ADC) lesions with conventional phase encoding and SENSE at MR imaging were compared; matched-pairs Wilcoxon signed rank test was used to test statistical significance. RESULTS: No major SENSE-related artifacts were seen. At MR imaging with SENSE, consistently and significantly (P < .001) higher image quality scores were achieved because of substantial reduction of image distortions and blurring. Lesion contrast was equivalent with both techniques. Diagnostic confidence for demonstration and exclusion of lesions was significantly (P < .001) higher at MR imaging with SENSE. In three patients, small microembolic lesions were only prospectively diagnosed at MR imaging with SENSE, whereas they were masked by adjacent susceptibility effects and therefore overlooked at MR imaging with conventional phase encoding. CONCLUSION: Parallel MR imaging with SENSE is feasible at 3.0 T. It significantly improves image quality, particularly by reducing or even preventing susceptibility-induced SI changes and image blurring. There was a significantly improved diagnostic confidence with which ADC changes were identified or excluded.

Adolescent↗