Search PubMed⌕ Search

Biomedical subjects

Christian F Vahl

Publications and source records attributed to Christian F Vahl.

11 recordsLinked to original sources

Poly(ADP-ribose) polymerase inhibitor PJ-34 reduces mesenteric vascular injury induced by experimental cardiopulmonary bypass with cardiac arrest.

The aim of this study was to investigate effects of poly(ADP-ribose) polymerase (PARP) inhibition on mesenteric vascular function and metabolism in an experimental model of cardiopulmonary bypass (CPB) with cardiac arrest. Twelve anesthetized dogs underwent 90-min hypothermic CPB. After 60 min of cardiac arrest, reperfusion was started for 40 min following application of either saline vehicle (control, n = 6) or a potent PARP inhibitor, PJ-34 (10 mg/kg iv bolus and 0.5 mg.kg(-1).min(-1) infusion for 20 min, n = 6). PJ-34 led to better recovery of cardiac output (2.2 +/- 0.1 vs. 1.8 +/- 0.2 l/min in control) and mesenteric blood flow (175 +/- 38 vs. 83 +/- 4 ml/min, P < 0.05 vs. control) after reperfusion. The impaired vasodilator response of the superior mesenteric artery to acetylcholine, assessed in the control group after CPB (-32.8 +/- 3.3 vs. -57.6 +/- 6.6% at baseline, P < 0.05), was improved by PJ-34 (-50.3 +/- 3.6 vs. -54.3 +/- 4.1% at baseline, P < 0.05 vs. control). Although plasma nitrate/nitrite concentrations were not significantly different between groups, mesenteric nitric oxide synthase activity was increased in the PJ-34 group (P < 0.05). Moreover, the treated group showed a marked attenuation of mesenteric venous plasma myeloperoxidase levels after CPB compared with the control group (75 +/- 1 vs. 135 +/- 9 ng/ml, P < 0.05). Pharmacological PARP inhibition protects against development of post-CPB mesenteric vascular dysfunction by improving hemodynamics, restoring nitric oxide production, and reducing neutrophil adhesion.

Animals↗

Regurgitant jet evaluation using three-dimensional echocardiography and magnetic resonance.

BACKGROUND: Three-dimensional assessment of regurgitant jet volume is the prerequisite for stratifying valve insufficiency. However, systematic comparison of three-dimensional methods is lacking. Therefore, we evaluated magnetic resonance imaging and three-dimensional echocardiography experimentally. METHODS: An insufficiency chamber (22 x 18.5 x 27 cm; ostia 10, 16, and 20 mm; regurgitant volumes 2.3 to 25 mL) within experimental circulation (BioMedicus pump, tubes, pulsatile flow 0.2 to 1.9 L/min) was used for three-dimensional echocardiography (HP Sonos 2500) and magnetic resonance imaging (Siemens Magnetom Vision). Doppler flowmeter served as a gold standard. Segmentation used thresholding and surface integration of velocity vectors. Jet volume was evaluated qualitatively by polynom fitting. RESULTS: Jet volume calculated by magnetic resonance (r = 0.99, p < 0.0001) and by echocardiography (r = 0.99, p < 0.0001) correlated identically to the gold standard. Jet volume derived from imaging correlated with each other by r = 0.98 (p < 0.0001). Polynom fits indicated a more paraboloid shape of magnetic resonance jet volume. CONCLUSIONS: Experimentally, three-dimensional echocardiography and magnetic resonance imaging possess identical accuracy for determining regurgitant jet volume. Magnetic resonance imaging seems to provide qualitatively better image data for three-dimensional reconstruction.

Echocardiography, Three-Dimensional↗

INO-1001 a novel poly(ADP-ribose) polymerase (PARP) inhibitor improves cardiac and pulmonary function after crystalloid cardioplegia and extracorporal circulation.

Poly(ADP-ribose) polymerase (PARP) activation plays a key role in free radical-induced injury in the context of systemic inflammation and ischemia/reperfusion. In the present preclinical study, we investigated the effects of INO-1001, a novel PARP inhibitor, on cardiac and pulmonary function during reperfusion in an experimental model of cardioplegic arrest and extracorporal circulation. Twelve anesthetized dogs underwent hypothermic cardiopulmonary bypass. After 60 min of hypothermic cardiac arrest, reperfusion was started after application of either saline vehicle (control, n = 6), or INO-1001 (1 mg/kg), a potent PARP inhibitor (n = 6). Biventricular hemodynamic variables were measured by combined pressure-volume-conductance catheters. Coronary and pulmonary blood flow and vasodilative responses to acetylcholine and sodium nitroprusside as well as pulmonary gas exchange were also determined. The administration of INO-1001 led to a significantly better recovery of left and right ventricular systolic function (P < 0.05) after 60 min of reperfusion. Coronary blood flow was also significantly higher in the INO-1001 group (P < 0.05). Although the vasodilative response to sodium nitroprusside was similar in both groups, acetylcholine resulted in a significantly greater increase in coronary and pulmonary blood flow in the INO-1001 group (P < 0.05). Pulmonary function in terms of alveolar arterial oxygen difference was better preserved in the INO-1001-treated group (P < 0.05). Thus, PARP inhibition improves the recovery of myocardial and endothelial function after hypothermic cardiac arrest and reduces pulmonary injury associated with extracorporal circulation.

Acetylcholine↗

Nitric oxide-sensitive soluble guanylyl cyclase activity is preserved in internal mammary artery of type 2 diabetic patients.

Vascular reactivity to nitric oxide (NO) is mediated by NO-sensitive soluble guanylyl cyclase (sGC). Since a diminished activity of vascular sGC has been reported in an animal model of type 2 diabetes, the sGC activity was assayed in vitro in internal mammary artery specimens obtained during bypass surgery from patients with and without type 2 diabetes. The sensitivity of sGC to NO, which is dependent on Fe(2+)-containing heme, was measured in vitro using stimulation with diethylamine NONOate (DEA/NO). In addition, the novel cyclic guanosine monophosphate-elevating compound HMR-1766 was used to test the stimulation of the oxidized heme-Fe(3+)-containing form of sGC. Basal activity of sGC and its sensitivity to stimulation by DEA/NO and HMR-1766 were not different between control and type 2 diabetic patients: maximum stimulation by DEA/NO amounted to 475 +/- 67 and 418 +/- 59 pmol. mg(-1). min(-1) in control and type 2 diabetic patients, respectively. The maximum effects of HMR-1766 were 95 +/- 18 (control subjects) and 83 +/- 11 pmol. mg(-1). min(-1) (type 2 diabetic patients). Hypertension, hyperlipidemia, drug treatment with statins, ACE inhibitors, or nitrates had no effect on sGC activity. In conclusion, the present findings do not support the hypothesis that desensitization of sGC contributes to the pathogenesis of diabetic vascular dysfunction in humans.

Aged↗

Expression of bone sialoprotein and bone morphogenetic protein-2 in calcific aortic stenosis.

BACKGROUND AND AIM OF THE STUDY: Calcific aortic stenosis, the major heart valve disease encountered in the elderly, leads to massive calcium deposition in the valve leaflets that morphologically resembles bone formation. Recent studies have demonstrated the expression of various bone-associated proteins in stenotic valves, suggesting that valvular calcification may be an actively regulated process. Bone sialoprotein (BSP), a non-collagenous bone matrix protein, and bone morphogenetic protein-2 (BMP-2), a member of the transforming growth factor cytokine superfamily, are known to participate in the regulation of bone development and maturation. Their pathogenetic role in calcific aortic stenosis is unknown. METHODS: Using an immunoperoxidase technique and antibodies against BSP and BMP-2, the expression of BSP and BMP-2 was examined in 16 human aortic valves with calcific aortic stenosis obtained at valve replacement, and in seven normal autopsy controls without signs of aortic stenosis. RESULTS: By semiquantitative scoring, stenotic valves showed a significantly increased staining of BSP in cells and extracellular matrix as compared to control valves (2.7 +/- 0.1 versus 0.6 +/- 0.2 score units, p <0.001). Marked BMP-2 expression was detected in stenotic valves, mostly in cell-rich areas associated with focal calcium deposits, but no specific staining for BMP-2 was detected in control valves (1.5 +/- 0.2 versus 0.0 +/- 0.0 score units, p <0.001). CONCLUSION: These results demonstrate for the first time that BSP and BMP-2 are differentially expressed in normal aortic valves and in aortic stenosis, thereby supporting the concept that valvular calcification might be based on an actively regulated process involving BSP and BMP-2.

Aged↗

In vivo validation of cardiac spiral computed tomography using retrospective gating.

BACKGROUND: Cardiac functional assessment represents the basis for diagnostics and cardiac operation planning. Spiral computed tomography (CT) combines the advantages of three-dimensional imaging and high temporal resolution when using gating techniques. However, in vivo validation data of this novel imaging technology are lacking. The purpose of this study was to validate in vivo the new imaging method using retrospective gating and to evaluate the clinical usefulness of the achieved temporal resolution. METHODS: In domestic pigs (n = 10, weight 35 to 40 kg) a flowmeter was placed surgically on the ascending aorta. Flow velocity integrated over systole served as the gold standard for left ventricular (LV) stroke volume (LVSV-FM). CT signal, projection data, pacemaker signal, and flow velocity were recorded simultaneously at constant heart rate (pacemaker, 90 beats per minute). End-systolic and end-diastolic frames were calculated by retrospective gating. LV volumes were traced, the difference representing CT stroke volume (LVSV-CT). Image data were three-dimensionally reconstructed using ray-tracing. RESULTS: Temporal resolution was 170 ms. Correlation of stroke volumes was high (r = 0.94, mean difference 1.75 mL). Intraobserver (0.49 mL for LVEDV, 0.31 for LVESV) and interobserver variability (p = 0.21 and p = 0.06, respectively) were low. Postprocessing resulted in four-dimensional beating-heart models useful for operation planning. CONCLUSIONS: Spiral CT using retrospective gating was validated in vivo. Clinically acceptable temporal resolution and accuracy in determining cardiac stroke volumes were found. As a true volumetric imaging modality the method may now play an important role in computer-assisted diagnostics and surgery.

Animals↗

Ventricular energetics after the Fontan operation: contractility-afterload mismatch.

OBJECTIVE: Fontan-type operations offer the opportunity to create pulmonary and systemic circulation in series with a single pumping chamber. The effectiveness of such a circulatory pattern determines resting and exercise hemodynamics in these patients. The present study investigated cardiac performance after the Fontan operation by using ventricular-vascular coupling framework analysis. METHODS: In 12 anesthetized open-chest dogs, Fontan circulation was established by using a cavopulmonary anastomosis. Left ventricular hemodynamic variables were measured by using a combined pressure-volume-conductance catheter. Additionally, aortic flow and pressure were recorded continuously. Ventricular contractility was quantified by using the load-independent slope of the end-systolic pressure-volume relationship. Arterial system properties were quantified by using the end-systolic pressure/stroke volume ratio. The coupling between the left ventricle and arterial system was expressed by using the ratio of end-systolic pressure/stroke volume to slope of the end-systolic pressure-volume relationship. Additionally, external stroke work, total mechanical energy and mechanical efficiency (Mechanical efficiency = Stroke work/Total mechanical energy) were calculated. Impedance spectra were determined by means of Fourier analysis. RESULTS: During Fontan circulation, the slope of the end-systolic pressure-volume relationship (5.3 +/- 0.6 vs 7.5 +/- 0.6 mm Hg/mL, P <.05) decreased, and the end-systolic pressure-stroke volume relationship (4.2 +/- 0.7 vs 3.3 +/- 0.5 mm Hg/mL, P =.23) increased with parallel increased characteristic impedance. Furthermore, the end-systolic pressure-stroke volume/slope of the end-systolic pressure-volume relationship ratio increased significantly (0.76 +/- 0.04 vs 0.42 +/- 0.03, P <.005). Simultaneously, stroke work (1846 +/- 146 vs 1389 +/- 60 mm Hg/mL, P <.05) and mechanical efficiency (0.82 +/- 0.09 vs 0.56 +/- 0.05, P <.05) were significantly reduced. CONCLUSIONS: Fontan circulation leads to contractility-afterload mismatch by means of increased impedance caused by additional connection of the pulmonary vascular bed to the systemic vasculature and by means of deterioration of myocardial contractility. The increased ventriculoarterial coupling ratio and reduced mechanical efficiency predict limited cardiac functional reserve after the Fontan operation.

Animals↗

Brain death impairs coronary endothelial function.

BACKGROUND: To characterize the impact of brain death (BD) on endothelial dysfunction after cardiac transplantation we investigated coronary circulation and vasomotor function in a canine model. METHODS: Left ventricular pressure-volume data (conductance catheter) and coronary blood flow (CBF) were monitored continuously. Endothelium-dependent vasodilatation after acetylcholine and endothelium-independent vasodilation after sodium nitroprusside were assessed before and 3 hr after BD induction (inflation of a subdural balloon). RESULTS: BD led to an initial hyperdynamic reaction with significant (P<0.05) increase of CBF. After 3 hr, CBF decreased significantly (P<0.05). Although before BD, application of acetylcholine led to a monophasic vasodilatative response, after BD a short mild vasodilatation was followed by a longer vasoconstriction. Endothelium-independent vasodilatation remained unchanged. CONCLUSIONS: BD affects coronary circulation by two means: (1) impairment of CBF to decrease in parallel in afterload with consecutive hemodynamic deterioration and (2) severe endothelial dysfunction that may be a contributing factor to posttransplant outcome.

Acetylcholine↗

Modulation of catecholamine responsiveness and beta-adrenergic receptor/adenylyl cyclase pathway during cardiac allograft rejection1 2.

BACKGROUND: This study investigated the changes of catecholamine responsiveness and beta-adrenergic receptor/adenylyl cyclase pathway during acute cardiac transplant rejection. METHODS: Isogeneic Lewis to Lewis and allogeneic Dark Agouti (DA) to Lewis rat cardiac transplants were studied 3 and 5 days after heterotopic intraabdominal transplantation (n=6/group). Myocardial blood flow (MBF), left ventricular systolic pressure (LVSP), maximum pressure development (+dP/dt), and end-diastolic pressure (LVEDP) were measured using an intraventricular balloon. Contractile response to dobutamine (5 microg/kg/min) was also assessed. In separate groups beta-adrenergic receptor density and adenylyl cyclase activity were measured in the grafts, in the recipients' native hearts and in native hearts of sham-operated controls. RESULTS: During mild to moderate rejection cardiac function indices remained unchanged, although MBF and contractile response to dobutamine decreased significantly (P<0.05) in the allogeneic group. The beta-adrenergic receptor density was significantly (P<0.05) increased in both isografts and allografts and in the native hearts of allografted recipients in comparison to native hearts of controls. Adenylyl cyclase activity showed a significant decrease (P<0.05) only in allografts. During severe rejection, LVSP and +dP/dt decreased and LVEDP increased in allografts in comparison to isografts (P<0.05). This was accompanied by a significant decrease in MBF, contractile response to dobutamine, beta-adrenergic receptor density, and adenylyl cyclase activity (P<0.05). CONCLUSIONS: Both microcirculatory disturbances and primary alteration in adenylyl cyclase activity may contribute to decreased contractile reserve in mild to moderate cardiac allograft rejection, whereas beta-adrenergic receptor density seems to be also influenced by cardiac denervation. Severe rejection leads to systolic and diastolic heart failure with complex dysregulation of the beta-adrenergic receptor/adenylyl cyclase pathway and impaired microcirculation.

Adenylyl Cyclases↗

Poly(ADP-Ribose) polymerase inhibition reduces reperfusion injury after heart transplantation.

The aim of the present study was to investigate the effects of the novel poly(ADP-ribose) polymerase (PARP) inhibitor PJ34 (N-(6-oxo-5,6-dihydro-phenanthridin-2-yl)-N,N-dimethylacetamide) on myocardial and endothelial function after hypothermic ischemia and reperfusion in a heterotopic rat heart transplantation model. After a 1-hour ischemic preservation, reperfusion was started either after application of placebo or PJ34 (3 mg/kg). The assessment of left ventricular pressure-volume relations, total coronary blood flow, endothelial function, myocardial high energy phosphates, and histological analysis were performed at 1 and 24 hours of reperfusion. After 1 hour, myocardial contractility and relaxation, coronary blood flow, and endothelial function were significantly improved and myocardial high energy phosphate content was preserved in the PJ34-treated animals. Improved transplant function was also seen with treatment with another, structurally different PARP inhibitor, 5-aminoisoquinoline. The PARP inhibitors did not affect baseline cardiac function. Immunohistological staining confirmed that PJ34 prevented the activation of PARP in the transplanted hearts. The activation of P-selectin and ICAM-1 was significantly elevated in the vehicle-treated heart transplantation group. Thus, pharmacological PARP inhibition reduces reperfusion injury after heart transplantation due to prevention of energy depletion and downregulation of adhesion molecules and exerts a beneficial effect against reperfusion-induced graft coronary endothelial dysfunction.

Adenosine Diphosphate↗

ROPES: a semiautomated segmentation method for accelerated analysis of three-dimensional echocardiographic data.

Echocardiography (cardiac ultrasound) is today the predominant technique for quantitative assessment of cardiac function and valvular heart lesions. Segmentation of cardiac structures is required to determine many important diagnostic parameters. As the heart is a moving organ, reliable information can be obtained only from three-dimensional (3-D) data over time (3-D + time = 4-D). Due to their size, the resulting four-dimensional (4-D) data sets are not reasonably accessible to simple manual segmentation methods. Automatic segmentation often yields unsatisfactory results in a clinical environment, especially for ultrasonic images. We describe a semiautomated segmentation algorithm (ROPES) that is able to greatly reduce the time necessary for user interaction and its application to extract various parameters from 4-D echocardiographic data. After searching for candidate contour points, which have to fulfill a multiscale edge criterion, the candidates are connected by minimizing a cost function to line segments that then are connected to form a closed contour. The contour is automatically checked for plausibility. If necessary, two correction methods that can also be used interactively are applied (fitting of other line segments into the contour and searching for additional candidates with a relaxed criterion). The method is validated using in vivo transesophageal echocardiographic data sets.

Algorithms↗