External Quality Assessment in The Netherlands: time to introduce commutable survey specimens. Lessons from the Dutch "Calibration 2000" project.

The performance of suitable secondary reference material for the use of trueness control of six routinely measured clinical enzymes in the Dutch External Quality Assessment (EQA) scheme is described. The reference material of choice was selected using the split-patient-sample between-field method (twin study) design as described in an earlier study of the Calibration 2000 project in The Netherlands. This material, which was proven to be commutable for all wet chemistry systems, was implemented as the national enzyme calibrator. It consisted of a cryo-protected lyophilised serum with additions of recombinant human enzymes. Various batches of the frozen version of this material without cryo-protection additive, called native EQA samples, were used in the general EQA scheme for performance evaluation. The results of Calibration 2000 calibrated and non-Calibration 2000 calibrated laboratories were compared for both the regular (spiked with non-human enzymes) and native EQA samples in terms of precision and bias with established reference method values for the native samples. The regular samples showed mean between-laboratory CV ranges for all six enzymes involved (low-high) of 5.5-10.3% for the non-calibrated users vs. 4.6-10.8% for the calibrated users. For the native samples these respective ranges were 5.2-9.9% vs. 2.2-4.9%. Without exception, the group of Calibration 2000 calibrated users showed the lowest bias against the reference method values. Regular EQA samples (spiked with non-human enzymes) showed poorer performance than native samples and are not suitable for accuracy assessment purposes, the main aim of EQA schemes. Native samples that are commutable should be used for trueness control in current EQA schemes.

Calibration↗

Deficiency of 17,20-lyase causing giant ovarian cysts in a girl and a female phenotype in her 46,XY sister: case report.

A 13-year-old girl was referred because of progressive abdominal pain caused by ovarian torsion and giant ovarian cysts. Secondary sexual characteristics were absent. Hormone analysis revealed markedly elevated serum levels of progesterone and 17-hydroxyprogesterone in combination with very low peripheral concentrations of C19 steroids (dehydroepiandrosterone and androstenedione) and estrogens. Serum concentrations of FSH and LH exceeded the upper limit of normal levels in adult women. The patient's 16-year-old 46,XY sibling showed a female phenotype with similar hormonal disturbances. Both siblings were found to be compound heterozygotes for two mutations in the CYP17 gene: an R347C mutation in one allele and a 25-base pair deletion in exon 1 in the other. The resulting block in 17,20-lyase activity caused an inability to synthesize androgens and estrogens, and increased levels of gonadotrophins due to a lack of negative feedback. The increased levels of gonadotrophins most likely stimulated growth of the ovarian cysts. The administration of a GnRH antagonist reduced the size of the cysts within a few weeks. At present, the girl is being treated with a combination of a GnRH agonist and hormone replacement therapy.

17-alpha-Hydroxyprogesterone↗

Genotyping of hemochromatosis-associated mutations in the HFE gene by PCR-RFLP and a novel reverse hybridization method.

Comparative analysis of the hemochromatosis-associated mutations C282Y, H63D and S65C in the HFE gene in 51 patients using three different methods is reported. One PCR-RFLP method was based on general primers, whereas another employed mutation-specific mismatched primers. The third method was a new PCR-based reverse hybridisation line probe assay (LiPA), comprising DNA amplification by general primers followed by a single step reverse hybridization to specific probes, immobilized on a nitrocellulose strip. Forty-eight (94%) of the 51 samples yielded identical results by all three methods. Three discrepant results were obtained, caused by polymorphisms in the primer binding region, resulting in no amplification at all or selective amplification, leading to misinterpretation of the HFE genotype by PCR-RFLP. The design of the assay and the stringency of the reaction conditions used are crucial to obtain a correct HFE genotype. PCR-LiPA offers an easy and reliable alternative to currently used conventional methods.

Base Sequence↗

Commutability assessment of potential reference materials using a multicenter split-patient-sample between-field-methods (twin-study) design: study within the framework of the Dutch project "Calibration 2000".

BACKGROUND: The Dutch project "Calibration 2000" aims at harmonization of laboratory results via calibration by development of commutable, matrix-based, secondary reference materials. An alternative approach to the NCCLS EP14 protocol for studying commutability of reference materials is presented, the "twin-study design", which in essence is a multicenter, split-patient-sample, between-field-methods protocol. METHODS: The study consisted of the simultaneous analysis of fresh patient sera and potential reference materials (PRMs) for HDL-cholesterol (HDL-C) by 86 laboratories forming 43 laboratory couples. Six subgroups of method combinations were formed. The patient sera were selected and interchanged by each laboratory couple. The PRMs consisted of three types: C37, prepared according to the NCCLS C37 protocol; Fro, frozen selectively pooled human serum; and Lyo, which was the same serum pool as Fro but lyophilized in the presence of sucrose. All PRMs were provided in three HDL-C concentrations. The regression line residuals for the PRMs were normalized by expressing them as multiples of the state-of-the-art within laboratory SD (SD(SA)). In addition, the extra contribution of each PRM to the total measurement uncertainty, CV(Netto), was calculated. RESULTS: Averaged over the three PRM concentrations, 1.6% of the C37 residuals were outside the 3 SD(SA) limit. For the Fro and Lyo PRMs, these values were 2.4% and 11.1%. CV(Netto) values for C37, Fro, and Lyo were 2.9%, 4.3%, and 5.3%, respectively. CONCLUSIONS: The present twin-study design, as a practical alternative to the NCCLS EP14 protocol, is a viable way of studying commutability characteristics of PRMs. The study suggests that the C37 PRMs are the best candidates for a future reference material.

Algorithms↗

Selection, preparation, and characterization of commutable frozen human serum pools as potential secondary reference materials for lipid and apolipoprotein measurements: study within the framework of the Dutch project "Calibration 2000".

BACKGROUND: The Dutch project "Calibration 2000" aims at harmonization of laboratory results via calibration by development of matrix-based secondary reference materials. We considered the selection, preparation, and characterization of 34 potential reference materials (PRMs). METHODS: Sixteen PRMs were prepared either strictly according to the NCCLS C37-A protocol or in a less stringent and more convenient way. In addition, 18 commercial, so-called human serum-based calibrators or controls were purchased and tested. Lipoprotein integrity was evaluated by examining the physicochemical characteristics of the materials. Commutability of the PRMs was assessed in 86 Dutch clinical laboratories, using a multicenter split-patient-sample between-field-method (twin-study) design. Normalized residuals of the PRMs with respect to the patient regression lines were calculated; in addition, the extra contribution of each PRM to the total measurement uncertainty (CV(Netto)) was calculated. On the basis of these results, the most native PRM was selected to investigate its potential to reduce interlaboratory variation and to improve lipid and apolipoprotein standardization. RESULTS: In general, only the NCCLS C37-A-type materials displayed normalized residuals below the decision limit for commutability and had small CV(Netto) values ranging between 0 and 3.8%. This contrasts with the findings in regularly pooled frozen sera and lyophilized cryoprotected PRMs. In two subsequent external quality assessment surveys, the NCCLS type C37-A materials contributed to reducing the intermethod lipid and (apo)lipoprotein variation to approximately 2-4%. CONCLUSIONS: NCCLS C37-A materials have a strong potential as secondary reference materials, not only for cholesterol but also for HDL-cholesterol, LDL-cholesterol, triglyceride, and apolipoprotein measurements.

Apolipoprotein A-I↗