Magnetic resonance imaging of phase transitions in nitinol.

Magnetic resonance images are prone to artifacts caused by metallic objects. Apart from being a source of image degradation, such artifacts can also provide information about the magnetic properties of the foreign object. In this work, we aim to explore the potential of magnetic resonance imaging to detect and characterize changes in magnetic properties of nitinol undergoing temperature- or strain-induced phase changes. A spin echo and a gradient echo method were used to measure the magnetization changes related to the phase transformations. Results of both methods were in agreement and in accordance with the independent measurements using a vibrating sample magnetometer. Magnetic resonance imaging turned out to be a suitable method to visualize and quantify magnetization and phase changes in situ. It is not restricted to a single imaging strategy and does not require any modification of the test object. The results indicate the potential of magnetic resonance imaging to provide direct feedback of the thermomechanical state of the alloy.

Alloys↗

Circle of Willis at CT angiography: dose reduction and image quality--reducing tube voltage and increasing tube current settings.

PURPOSE: To prospectively assess the effects of lower tube voltage and various effective tube currents on image quality for computed tomographic (CT) angiography of the circle of Willis. MATERIALS AND METHODS: Institutional review board approval was obtained. Patients or family provided written informed consent. Signal-to-noise ratios (SNRs) were determined in a head phantom for various effective tube currents with tube voltages of 90, 120, and 140 kVp. Patients were referred for CT angiography because of acute subarachnoid hemorrhage (n = 20) or family history of cerebral aneurysms (n = 20). In each group, 10 patients were scanned with 120 kVp and 200 mAs(eff) and 10 were scanned with 90 kVp and 330 mAs(eff) (CT dose index volumes, 27.2 mGy and 20.6 mGy, respectively). CT numbers were measured in the internal carotid artery at the T junction and compared with a t test. Two radiologists used a five-point scale to subjectively score arterial enhancement, depiction of small arterial detail, image noise, venous contamination, and interference of subarachnoid blood. Mann-Whitney U test was used for statistical analysis. RESULTS: In the phantom, SNR(2) was proportional to effective tube current and CT dose index volume. With an identical effective tube current, SNR(2) was lower at 90 kVp than at 120 or 140 kVp. With identical CT dose index volume, tube voltage of 90 kVp resulted in a 45%-52% increase of SNR(2) compared with SNR(2) at 120 kVp. In patients, mean attenuation in the internal carotid artery T junction was higher with 90 kVp (340 HU) than with 120 kVp (252 HU, P < .001). Although dose at 90 kVp was 30% lower than dose at 120 kVp, scores for arterial enhancement and depiction of small arterial detail were higher at 90 kVp than at 120 kVp (4.0 vs 3.2 and 3.6 vs 3.1, respectively; P < .005). CONCLUSION: In head phantoms, lower tube voltage improved SNR at equal radiation doses. For CT angiography of the circle of Willis, this translated into superior image quality at 90 kVp.

Adult↗

Correction of proton resonance frequency shift temperature maps for magnetic field disturbances caused by breathing.

Respiratory induced resonance offset (RIRO) is a periodic disturbance of a magnetic field due to breathing. Such disturbance handicaps the accuracy of the proton resonance frequency shift (PRFS) method of MRI temperature mapping in anatomies situated nearby the lungs and chest wall. In this work, we propose a method capable of minimizing errors caused by RIRO in PRFS temperature maps. In this method, a set of baseline images characterizing RIRO at a variety of respiratory cycle instants is acquired before the thermal treatment starts. During the treatment, the temperature evolution is found from two successive images. Then, the calculated temperature changes are corrected for the additional contribution caused by RIRO using the pre-treatment baseline images acquired at the identical instances of the respiratory cycle. Our method is shown to improve the accuracy and stability of PRFS temperature maps in the presence of RIRO and inter-scan motion in phantom and volunteers' breathing experiments. Our method is also shown to be applicable to anatomies moving during breathing if a proper registration procedure is applied.

Electromagnetic Fields↗

Feasibility and measurement precision of 3D quantitative blood flow mapping of the prostate using dynamic contrast-enhanced multi-slice CT.

We have developed a 3D dynamic contrast-enhanced (DCE) multislice CT protocol that covers the complete prostate. The DCE-CT data are subsequently analysed using the adiabatic approximation of the tissue homogeneity model resulting in five 3D quantitative maps of blood flow, mean transit time, extraction fraction, extracellular extravascular space and delay time. The purpose of this study was to establish the feasibility of determining these parameters in the prostate with a spatial resolution as high as approximately 0.1 cc as well as a good measurement precision. The precision of the parameter estimation as a function of noise level is determined by a Monte Carlo-based method that simulates the effect of noise present in the data. We find that the precision depends on the value of the flow and transit time, where a higher value is favourable. At a noise level of 4 HU in combination with a peak enhancement in the iliac arteries of approximately 300 HU the 95% confidence intervals are sufficiently small to discriminate whether a parameter value is above or below a given threshold. We have collected and analysed the noise level in the DCE-data of five patients. A noise level of 3.8 HU on average can be obtained by averaging to a voxel volume of 4.5 x 4.5 x 5 mm(3) = 0.1 cc. Analysis of the parameter maps shows that it is feasible to detect both small and large lesions, as well as irregularly shaped lesions.

Contrast Media↗

MRI temperature mapping during thermal balloon angioplasty.

Knowledge on the thermal dose delivered during thermal balloon angioplasty (TBA) is desirable to understand why TBA's outcome varies widely among patients and why it is subject to high restenosis rates. In its conventional implementation, TBA involves injection of a heated medium into a balloon positioned within a stenotic blood vessel. The medium injection causes flow, motion and susceptibility-redistribution artefacts that are devastating to the proton resonance frequency shift (PRFS) technique of MRI temperature mapping. Here, we propose to separate in time medium injection and heating by first inflating a balloon with a medium at an initial temperature, and then by heating the medium up using laser light. The separation is shown to eliminate all the mentioned artefacts and to enable real-time MRI temperature mapping using the PRFS technique. Accurate and reliable temperature maps were acquired in a TBA balloon itself and in the surrounding phantom tissue during heat application.

Angioplasty, Balloon↗

Magnetic resonance imaging of microstructure transition in stainless steel.

Magnetic resonance images are prone to artifacts caused by metallic objects. Such artifacts may not only hamper image interpretation, but also have been shown to provide information about the magnetic properties of the substances involved. In this work, we aim to explore the potential of MRI to detect, localize and characterize changes in magnetic properties that may occur when certain alloys have been exposed to a thermomechanical stress. For this purpose, stainless steel 304 L wires were drawn to induce a change from paramagnetic austenitic into ferromagnetic martensitic microstructure. The changes in magnetic behavior were quantified by analyzing the geometric distortion in spin echo and the geometric distortion and intravoxel dephasing in gradient echo images at 0.5, 1.5 and 3 T. The results of both imaging strategies were in agreement and in accordance with independent measurements with a vibrating sample magnetometer. Drawing wire to 2% of its cross-sectional area was found to increase the volume fraction of the ferromagnetic martensite from 0.3% to 80% and to enhance the magnetization up to two or three orders of magnitude. The results demonstrate the potential of MRI to locate and quantify stress-induced changes in the magnetic properties of alloys in a completely noninvasive and nondestructive way.

Elasticity↗

Fully MR-guided hepatic artery catheterization for selective drug delivery: a feasibility study in pigs.

PURPOSE: To demonstrate the feasibility of hepatic catheterization for selective delivery of therapeutic agents using a clinical MRI scanner for real-time image guidance. MATERIALS AND METHODS: Experiments were performed in three domestic pigs (70-80 kg) using a clinical 1.5-T MR scanner. After abdominal three-dimensional contrast-enhanced MR angiography (3D-CE-MRA) was performed, endovascular devices with susceptibility markers were tracked with passive tracking techniques. Catheters were maneuvered into the primary and secondary hepatic arteries. Selective catheterization was verified using selective time-resolved CE angiography. Paramagnetic microspheres were administered to a different region for each liver. The resulting biodistributions were investigated using MR images. RESULTS: Successful selective hepatic catheterization was repeatedly demonstrated using passive tracking techniques. 3D-CE-MRA significantly aided the interventional procedure by showing the vascular anatomy, and maximum-intensity projections (MIPs) were used as roadmaps during the interventions. In all cases, microspheres were successfully delivered to the selected regions. The catheters were visualized at a maximum frame rate of five frames per second, allowing a good depiction of the devices and a reliable catheterization of the hepatic arteries. CONCLUSION: Fully MR-guided real-time navigation of endovascular devices permits complex procedures such as selective intra-arterial delivery of therapeutic agents to parts of the liver.

Animals↗

Dephased MRI.

In this work gradient dephasing is treated as a mechanism for manipulating contrast in otherwise conventional MR images. The paper provides a theoretical and experimental framework for this approach. It starts from the observation that dephasing gradients invoke a shift in k-space. From this it is inferred that the effects of in-plane and through-plane dephasing can be systematically explored in the context of any given imaging experiment by sampling k-space more widely and densely than dictated by the field of view (FOV) and the spatial resolution of the desired images. The oversampled k-space allows an ensemble of lower-resolution dephased images to be reconstructed in which the degree and direction of dephasing are determined by the off-center position of the reconstruction window. The efficacy of this approach is demonstrated for standard gradient-echo acquisitions in a phantom. The results indicate the potential of the proposed methodology for evaluating 3D image data and optimizing gradient dephasing in applications that rely on the exploitation of partial volume and susceptibility effects (e.g., tracking interventional devices and tracing magnetically labeled substances).

Gels↗

Concerning the preparation and use of substances with a magnetic susceptibility equal to the magnetic susceptibility of air.

In this work it is demonstrated that the susceptibility of diamagnetic substances, such as water and agarose gel, can easily be tuned to the susceptibility of air by the addition of a proper amount of strongly paramagnetic ions, in this case 16.6 +/- 0.1 mM holmium(III). The resultant air-equivalent substances are shown to allow the creation of objects that do not disturb the static magnetic field of the scanner and hence do not invoke susceptibility artifacts, regardless of the objects' shape, size, and orientation with respect to B(0), and regardless of the pulse sequence being used. The addition of the proper amount of holmium(III) to aqueous solutions and gels is further shown to exert a negligible influence on the chemical shift and to cause a moderate increase of the relaxation rates 1/T(1) and 1/T(2). The results indicate the potential of air-equivalent substances for many purposes, including construction of artifact-free test objects; experimental setups and accessory devices; investigation of systems that contain air cavities, gas bubbles, etc.; and monitoring of system-related and object-induced field disturbances.

Air↗

Lanthanide-loaded liposomes for multimodality imaging and therapy.

UNLABELLED: Many advanced molecular imaging agents are currently being investigated preclinically. Especially, liposomes, have proven to be very promising carrier systems for diagnostic agents for use in single-photon emission computed tomography (SPECT) or magnetic resonance imaging (MRI), as well as for therapeutic agents to treat diseases such as cancer. In this study, nanosized liposomes were designed and labeled with the radionuclides, holmium-166 (both a beta- and gamma-emitter and also highly paramagnetic) or technetium-99m, and coloaded with paramagnetic gadolinium allowing multimodality SPECT and MR imaging and radionuclide therapy with one single agent. METHODS: Diethylenetriaminepentaacetic acid bisoctadecylamide (an amphiphilic molecule with a chelating group suitable for labeling with radionuclides) and gadoliniumacetylacetonate (GdAcAc) (a small lipophilic paramagnetic molecule) were incorporated in liposomes. The liposomes were characterized by measuring their mean size and size distribution, gadolinium content, and radiochemical stability after incubation in human serum at 37 degrees C. The MRI properties (in vitro) were determined by use of relaxivity measurements at 1.5 and 3.0 Tesla in order to evaluate their potency as imaging agents. RESULTS: The liposomes were successfully labeled with holmium-166, resulting in a high labeling efficiency (95% +/- 1%) and radiochemical stability (> 98% after 48 hours of incubation), and coloaded with GdAcAc. Labeling of liposomes with technetium-99m was somewhat less efficient (85% +/- 2%), although their radiochemical stability was sufficient (95% +/- 1% after 6 hours of incubation). MRI measurements showed that the incorporation of GdAcAc had a strong effect on the MRI relaxivity. CONCLUSIONS: The synthesized liposomes allow for multimodality imaging and therapy, which makes these new agents highly attractive for future applications.

Lanthanoid Series Elements↗

Non-invasive visualization of collateral blood flow patterns of the circle of Willis by dynamic MR angiography.

The circle of Willis plays an important role in the distribution of blood flow in the brain. To obtain dynamic information of the blood flow through the circle of Willis, a dynamic MRA technique based on arterial spin labeling (ASL) is introduced as a non-invasive technique. When the ASL labeling slab is restricted to a single artery, it is possible to visualize selectively the flow distribution of that specific artery. However, because of the decay of the label and the presence of noise it is difficult to extract functional information from these images. In the present study we propose three visualization and post-processing methods for the interpretation of these images. Firstly, the passage of labeled blood was corrected for decay of the label and hereafter shown as a movie. Secondly, by calculating the time of arrival at every location in the arteries of the circle of Willis, a 2D image was reconstructed summarizing the information of the movie. Finally, quantitative flow values were obtained by relating the arterial input function to the passage of labeled blood through a region of interest encompassing the vessel under investigation. Experiments in a circle of Willis phantom showed a high linear relation between measured flow and true flow, although the measured values were 10-15% lower than the true flow values. Measurements in healthy volunteers showed the potential to quantify the flow in all major arteries of the circle of Willis.

Circle of Willis↗

Spectral characterization of local magnetic field inhomogeneities.

The purpose of this study was the characterization of local magnetic susceptibility deviations by spectral analysis of their induced magnetic field inhomogeneities. Magnetic resonance spectra and related signal decay curves of local susceptibility deviations were simulated for different volume fractions and compositions of the object within the VOI. The size or composition of the object was varied at constant volume fraction, constant object size, or at constant 'magnetic strength' (defined as the product of the volume and the volume susceptibility of the object). Experimental spectra were acquired for individual metal spherical particles and a spherical air cavity. Where possible, spectra were used to characterize objects in terms of volume and composition. By simulations, a numerical relation was determined between the spectral broadening and the object's volume and composition. Comparison of spectra for various spherical objects showed the possibility of characterization with respect to size and composition. Experimental results confirmed the numerical results to a large extent, although the characterization was compromised by background signal decay, low volume fractions and limitations in signal-to-noise. In conclusion, spectral description of the field inhomogeneities related to small objects allows characterization of such objects with respect to size and composition. Practical applicability of the simulation results depends on background signal decay and volume fraction of the object.

Animals↗

Partial volume effects on arterial input functions: shape and amplitude distortions and their correction.

For quantification of perfusion values from a bolus-tracking MRI experiment, the measurement of an arterial input function (AIF) is necessary. Gradient-echo (GE) sequences are commonly used for this type of experiment because they offer a high signal-to-noise ratio (SNR) and the potential to quantify the concentration of contrast agent. Measurements of calibration curves for Gd-DTPA in human blood have shown a quadratic relation between the DeltaR(2)* and the concentration of contrast agent, and a linear relationship between phase changes and the concentration of contrast agent. However, for in vivo studies the spatial resolution is usually limited, which leads to partial volume effects. Partial volume effects result in a complex sum of signal arising from the tissue outside the vessel and a contrast agent concentration-dependent blood signal. Ignoring the presence of partial volume effects can lead to an overestimation or underestimation of the contrast agent concentration, depending on the experimental conditions. Correction for partial volume effects is feasible in arteries that are parallel to the main magnetic field by estimation and subtraction of the static signal of the surrounding tissue. Patient studies showed a large variation due to the AIF measurements, but it has also been shown that this influence can be minimized by correction for partial volume effects.

Arteries↗

Analysis and correction of gradient nonlinearity and B0 inhomogeneity related scaling errors in two-dimensional phase contrast flow measurements.

Phase contrast flow measurements will be increasingly biased at eccentric positions, where nonlinearity of gradients and inhomogeneity of the main field become important. In theory, they scale the result of phase contrast flow values in two ways: incorrect velocity encoding of moving spins and geometric distortion of the vessel cross-sectional area. A flow phantom, consisting of a 3D grid of interconnected tubes, was used to determine the spatial dependence of the associated scaling factors, which demonstrate that scaling errors in flow can be as large as 20% within the examined volume of 336 x 336 x 336 mm(3). The same phantom was also used to determine and minimize concomitant gradient effects. Correction of the off-center flow values with the local scaling factors and the concomitant gradient phase improves the measurement accuracy substantially, both in the flow phantom and in a volunteer study.

Adult↗

Internal radiation therapy of liver tumors: qualitative and quantitative magnetic resonance imaging of the biodistribution of holmium-loaded microspheres in animal models.

In internal radiation therapy of unresectable liver tumors, microspheres containing a radionuclide are injected in the hepatic artery to achieve a preferential deposition of microspheres in the lesions. In this study, MR imaging techniques for qualitative and quantitative assessment of the biodistribution of holmium-loaded microspheres (HoMS) were investigated for their use in selective internal radiation therapy of liver tumors. To achieve this goal, the relaxivity of HoMS was first investigated in gel experiments. The resultant calibration curve was subsequently employed to quantify the biodistribution of HoMS administered to 13 excised rabbit livers and to the livers of 3 live rabbits with an implanted tumor. Finally, the feasibility of MR imaging of the biodistribution during treatment of a large animal was investigated by MR imaging of hepatic administration of HoMS to a live pig. Overall, the study showed that MRI can clearly depict the biodistribution of HoMS, but that quantification by means of the gel calibration curve yields an underestimation that increases for higher amounts of HoMS. The observed underestimation is tentatively attributed to accumulations of HoMS in larger liver vessels. The exploratory quantification experiments suggest the feasibility of MR dosimetry.

Animals↗

Renal blood flow measurements with use of phase-contrast magnetic resonance imaging: normal values and reproducibility.

PURPOSE: To assess the validity and the direct, short-term, and long-term reproducibility of renal blood flow (RBF) measurements with phase-contrast (PC) magnetic resonance (MR) imaging. MATERIALS AND METHODS: In 20 healthy volunteers, RBF measurements were repeated with and without repositioning. Internal validity was assessed by comparing the total RBF with the difference in aortic flow above and below the renal arteries. In 19 healthy volunteers, RBF measurements were performed at two different occasions. In 40 healthy volunteers, RBF measurements were performed to assess normal values as a function of age. Analyses were performed according to Bland and Altman. RESULTS: The technical success rate ranged from 78% to 85%. Total RBF and the difference in aortic flow rates showed good agreement (Pearson correlation coefficient, 0.72; P = .002). Directly repeated measurements had a mean difference of 54 mL/min in total RBF with a coefficient of variation (CV) of 17%. For repeated measurements with repositioning, the mean difference in total RBF was 74 mL/min (CV, 23%). Repeated measurements on different occasions showed a CV of 20%. The mean total RBF of the 40 healthy volunteers was 838 mL/min +/- 244 (SD). CONCLUSIONS: RBF measurement with PC MR has a success rate greater than 75%. The demonstrated internal reliability of this method and fair reproducibility of the flow parameters is crucial for further studies of the renal artery with MR imaging.

Adult↗

Internal carotid artery occlusion assessed at pulsed arterial spin-labeling perfusion MR imaging at multiple delay times.

Magnetic resonance (MR) imaging with pulsed arterial spin labeling (ASL) was performed at six different inversion times in nine patients with internal carotid artery (ICA) occlusion and in 11 control subjects. The hospital's commission on scientific research on human subjects approved the study protocol, and all study subjects gave informed consent. Cerebral blood flow (CBF) in the middle cerebral artery territories was calculated from the combined signal intensities measured with ASL at the multiple inversion times. In the patients with ICA occlusion, mean CBF values were decreased in the gray matter of the hemisphere ipsilateral to the occlusion, as compared with values in the gray matter of the contralateral hemisphere (P < .05) and with values in the gray matter of the control subjects (P < .05). Quantification of CBF with ASL at multiple inversion times can compensate for the blood transit delays in patients with ICA occlusion.

Adult↗

Liver tumors: MR imaging of radioactive holmium microspheres--phantom and rabbit study.

PURPOSE: To investigate the use of magnetic resonance (MR) imaging in the administration and biodistribution of holmium-loaded poly(L-lactic acid) microspheres (Ho-PLLA-MS) in liver tumors. MATERIALS AND METHODS: MR imaging measurements were obtained in phantoms, three ex vivo rabbit livers, and four livers in living rabbits. When applicable, measurements were compared with those on scintigraphic images. The transverse relaxivity R2* of the Ho-PLLA-MS was determined in a phantom study. The in vivo animal experiments were performed by using rabbits with an implanted VX2 tumor. Detection of passing Ho-PLLA-MS to estimate lung shunting was performed in a scaled model of the vena cava. RESULTS: In the ex vivo liver experiments, the feasibility of real-time MR imaging during administration of microspheres was demonstrated. The in vivo rabbit experiments demonstrated that MR imaging can depict radioactive, nonradioactive, and decayed Ho-PLLA-MS after treatment for as long as they remain in the body. Furthermore, this study showed the ability of dynamic MR imaging to detect single doses of passing Ho-PLLA-MS. CONCLUSION: Ho-PLLA-MS used for internal radionuclide therapy can be imaged clearly in vivo with MR imaging.

Animals↗