Search PubMed⌕ Search

Biomedical subjects

Chien-Chung Tsai

Publications and source records attributed to Chien-Chung Tsai.

7 recordsLinked to original sources

Development of a new method for small bowel transit study.

BACKGROUND AND PURPOSE: Currently, most studies combine the small bowel transit examination with gastric emptying time examination. There are significant drawbacks to this method. The radiotracer does not enter the small intestine in a bolus and the starting time for transit in the duodenum is difficult to define. This makes the result unreliable. In this study, we used a commercial enteric capsule containing radioactive charcoal to solve these problems. MATERIALS AND METHODS: Activated charcoal powder was mixed with Tc-99m pertechnetate and loaded to the enteric capsule which can resist gastric acid and dissolve only in the small intestine. In-vitro stability experiment was performed by immersing these capsules in a colorless phosphate buffer of variable pH which mimicked the condition in stomach and small intestine. In addition, ten healthy Chinese volunteers were included for in-vivo experiment. Anterior and posterior views of abdomen were obtained at regular 30-minute intervals until the eighth hour after administration of the radioactive enteric capsule. Small bowel transit time was calculated. RESULTS: The enteric capsule remained intact for at least 480 minutes in the solution mimicking gastric content (pH = 3.0) and disrupted at a mean duration of 227.2 minutes at a pH of 6.8 and at a mean duration of 212.4 minutes at a pH of 7.4 in the solution mimicking pancreaticobiliary secretions. In nine of ten volunteers, the small bowel transit time was between 30 to 270 minutes with a mean transit time of 140 min. In one volunteer, we failed to detect the exact time of small bowel transit because the capsule remained in the stomach throughout the study for up to 8 hours. CONCLUSIONS: We consider activated charcoal labeled with Tc-99m pertechnetate using an enteric capsule as the carrier to be a potential radioactive marker for small bowel transit study.

Administration, Oral↗

Effectiveness of delayed 2-day lymphoscintigraphy on sentinel lymph node detection in patients with breast cancer with negative early lymphoscintigraphy.

PURPOSE: Most centers perform lymphoscintigraphy for the detection of sentinel lymph node (SLN) in patients with breast cancer within 2 hours after radiotracer injection. However, the interval between the injection of the radiotracer and surgery may not be long enough. In this study, we evaluated the effectiveness of delayed imaging (more than 15 hours) for SLN detection in patients with negative early images. METHODS: We retrospectively analyzed a database of 401 patients with breast cancer referred for SLN detection. On the day before surgery, lymphoscintigrams were obtained at 30-minute intervals until SLN was detected or 120 minutes. In those patients who failed to localize SLN on the early images, delayed imaging was performed the next morning. RESULTS: Twenty-seven (6.7%) patients failed to show SLN on the early images. In the 27 patients, delayed imaging was available for 14 patients but not for 13 patients resulting from the tight time schedule for surgery. Of the 14 patients with delayed images, SLNs were successfully harvested in 10 patients (71.4%) at surgery. In contrast, in the 13 patients who lacked delayed images, SLN was only harvested in one case (7.7%) at surgery. The intraoperative detection rate for SLN was significantly higher in the 14 patients with delayed images than that in the 13 patients without delayed images. CONCLUSIONS: Two-day delayed imaging is significantly useful to increase the rate of localizing SLN at surgery in patients with a negative early image.

Breast Neoplasms↗

Balanced detector interferometric ellipsometer.

A novel balanced detector interferometric ellipsometer (BDIE), composed of a polarized common-path optical heterodyne interferometer incorporating a novel balanced detector, provides an amplitude-sensitive method for measurement of the elliptical parameters of a thin film. The requirement for equal amplitude of the polarized heterodyne signals for balanced detection results in the simultaneous measurement of the elliptical parameters in terms of the azimuth angle of a half-wave plate and the output intensity from the differential amplifier, respectively. The common-path feature of BDIE shows a common phase noise rejection mode and this enhances the sensitivity of the phase measurement. At the same time, the balanced detector configuration of BDIE reduces excess noise of laser intensity fluctuation to give better sensitivity during measurement. The error of measurement of BDIE is derived and analyzed. Finally, the elliptical polarization effect of the laser beam is found to be independent of the measurement of the elliptical parameters.

Journal Article↗

Determination of optical parameters of a twisted-nematic liquid crystal by phase-sensitive optical heterodyne interferometric ellipsometry.

What is believed to be a novel phase-sensitive optical heterodyne interferometric ellipsometer is set up to characterize a twisted-nematic liquid crystal (TN-LC) by the elliptical parameters of the output polarization state. This ellipsometer presents the advantages of both polarized optical heterodyne interferometry and optical photometry, which introduce a polarization modulation that is capable of performing with high-sensitivity on phase detection in real time. The twist angle phi and the untwisted phase retardation gamma of TN-LC are measured precisely. The experimental results verify that a TN-LC can be treated as identical to an elliptical retarder.

Journal Article↗

Tc-99m(V)-DMSA in wound infection after closure of an ileostomy.

We present a 71-year-old man who underwent closure of an ileostomy and had a fever seven days post surgery. Both Tc-99m(V)-dimercaptosuccinic acid (DMSA) and gallium-67 citrate scans showed increased tracer accumulation in the right lower quadrant of the abdomen. Tc-99m(V)-DMSA scintigraphy can be a rapid alternative tool in the detection of wound infection in patients after ileostomy closure.

Aged↗

Comparison of Tc-99m sestamibi and F-18 FDG-PET in the assessment of multiple myeloma.

BACKGROUND: Tc-99m methoxy-isobutyl-isonitrile (MIBI) has been reported to be a useful tracer in patients with multiple myeloma (MM). Few articles have reported the potential value of fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) in the evaluation of MM. Therefore, the purpose of this study was to compare the diagnostic abilities of the MIBI scan and the FDG-PET scan in the evaluation of MM. MATERIALS AND METHODS: Twelve patients with MM were included. All patients received a radiological skeletal survey, MIBI scan and FDG-PET scan. RESULTS: Thirty-four lesions (19 soft tissue lesions and 15 skeletal lesions) plus 5 cases of bone marrow involvement were detected. The conventional skeletal X-ray survey detected 4 soft tissue lesions (21.1%), 12 skeletal lesions (80%), but no bone marrow involvement (0%). The MIBI scan found 4 cases of bone marrow involvement (80%), 13 soft tissue lesions (68.4%) and 12 skeletal lesions (80%). The PET scan detected 5 cases of bone marrow involvement (100%), 17 soft tissue lesions (89.5%) and 14 skeletal lesions (93.3%). CONCLUSION: Both the MIBI and the FDG-PET scans are useful in the evaluation of patients with MM. However, FDG-PET can detect more lesions than the MIBI scan in patients with MM.

Adult↗