Search PubMed⌕ Search

Biomedical subjects

Chien Ho

Publications and source records attributed to Chien Ho.

43 records · Page 3Linked to original sources

NMR investigation of the dynamics of tryptophan side-chains in hemoglobins.

NMR relaxation measurements of 15N spin-lattice relaxation rate (R(1)), spin-spin relaxation rate (R(2)), and heteronuclear nuclear Overhauser effect (NOE) have been carried out at 11.7T and 14.1T as a function of temperature for the side-chains of the tryptophan residues of 15N-labeled and/or (2H,15N)-labeled recombinant human normal adult hemoglobin (Hb A) and three recombinant mutant hemoglobins, rHb Kempsey (betaD99N), rHb (alphaY42D/betaD99N), and rHb (alphaV96W), in the carbonmonoxy and the deoxy forms as well as in the presence and in the absence of an allosteric effector, inositol hexaphosphate (IHP). There are three Trp residues (alpha14, beta15, and beta37) in Hb A for each alphabeta dimer. These Trp residues are located in important regions of the Hb molecule, i.e. alpha14Trp and beta15Trp are located in the alpha(1)beta(1) subunit interface and beta37Trp is located in the alpha(1)beta(2) subunit interface. The relaxation experiments show that amino acid substitutions in the alpha(1)beta(2) subunit interface can alter the dynamics of beta37Trp. The transverse relaxation rate (R(2)) for beta37Trp can serve as a marker for the dynamics of the alpha(1)beta(2) subunit interface. The relaxation parameters of deoxy-rHb Kemspey (betaD99N), which is a naturally occurring abnormal human hemoglobin with high oxygen affinity and very low cooperativity, are quite different from those of deoxy-Hb A, even in the presence of IHP. The relaxation parameters for rHb (alphaY42D/betaD99N), which is a compensatory mutant of rHb Kempsey, are more similar to those of Hb A. In addition, TROSY-CPMG experiments have been used to investigate conformational exchange in the Trp residues of Hb A and the three mutant rHbs. Experimental results indicate that the side-chain of beta37Trp is involved in a relatively slow conformational exchange on the micro- to millisecond time-scale under certain experimental conditions. The present results provide new dynamic insights into the structure-function relationship in hemoglobin.

Amino Acid Substitution↗

Recombinant hemoglobins with low oxygen affinity and high cooperativity.

By introducing an additional H-bond in the alpha(1)beta(2) subunit interface or altering the charge properties of the amino acid residues in the alpha(1)beta(1) subunit interface of the hemoglobin molecule, we have designed and expressed recombinant hemoglobins (rHbs) with low oxygen affinity and high cooperativity. Oxygen-binding measurements of these rHbs under various experimental conditions show interesting properties in response to pH (Bohr effect) and allosteric effectors. Proton nuclear magnetic resonance studies show that these rHbs can switch from the oxy (or CO) quaternary structure (R) to the deoxy quaternary structure (T) without changing their ligation states upon addition of an allosteric effector, inositol hexaphosphate, and/or reduction of the ambient temperature. These results indicate that if we can provide extra stability to the T state of the hemoglobin molecule without perturbing its R state, we can produce hemoglobins with low oxygen affinity and high cooperativity. Some of these rHbs are also quite stable against autoxidation compared to many of the known abnormal hemoglobins with altered oxygen affinity and cooperativity. These results have provided new insights into the structure-function relationship in hemoglobin.

Adult↗

Effects of amino acid substitutions at beta 131 on the structure and properties of hemoglobin: evidence for communication between alpha 1 beta 1- and alpha 1 beta 2-subunit interfaces.

Substitutions of Asn, Glu, and Leu for Gln at the beta131 position of the hemoglobin molecule result in recombinant hemoglobins (rHbs) with moderately lowered oxygen affinity and high cooperativity compared to human normal adult hemoglobin (Hb A). The mutation site affects the hydrogen bonds present at the alpha(1)beta(1)-subunit interface between alpha103His and beta131Gln as well as that between alpha122His and beta35Tyr. NMR spectroscopy shows that the hydrogen bonds are indeed perturbed; in the case of rHb (beta131Gln --> Asn) and rHb (beta131Gln --> Leu), the perturbations are propagated to the other alpha(1)beta(1)-interface H-bond involving alpha122His and beta35Tyr. Proton exchange measurements also detect faster exchange rates for both alpha(1)beta(1)-interface histidine side chains of the mutant rHbs in 0.1 M sodium phosphate buffer at pH 7.0 than for those of Hb A under the same conditions. In addition, the same measurements in 0.1 M Tris buffer at pH 7.0 show a much slower exchange rate for mutant rHbs and Hb A. One of the mutants, rHb (beta131Gln --> Asn), shows the conformational exchange of its interface histidines, and exchange rate measurements have been attempted. We have also conducted studies on the reactivity of the SH group of beta93Cys (a residue located in the region of the alpha(1)beta(2)-subunit interface) toward p-mercuribenzoate, and our results show that low-oxygen-affinity rHbs have a more reactive beta93Cys than Hb A in the CO form. Our results indicate that there is communication between the alpha(1)beta(1)- and alpha(1)beta(2)-subunit interfaces, and a possible communication pathway for the cooperative oxygenation of Hb A that allows the alpha(1)beta(1)-subunit interface to modulate the functional properties in conjunction with the alpha(1)beta(2) interface is proposed.

Amino Acid Substitution↗

MRI of lungs using partial liquid ventilation with water-in-perfluorocarbon emulsions.

A novel (1)H-MRI contrast modality for rat lungs has been developed using water-in-perfluorocarbon (PFC) emulsions for partial liquid ventilation (PLV). The feasibility of the new ventilation protocol for (1)H-MRI studies of lungs has been demonstrated. (1)H-MR images of lungs have been obtained with sensitivity and spatial resolution higher than those of the (19)F-MRI of lungs previously reported. Diffusion-weighted MRI measurements of lungs showed that the results obtained are related to the pulmonary architecture and functional properties of lungs. Although the methodology needs further improvement and evaluation, it appears to have great potential in a wide range of new applications in the field of lung MRI, such as in vivo detection of lung cancer, emphysema, and allograft rejection following lung transplantation. The ability of this technique to achieve high-quality MR images of lungs, together with its technical simplicity, stability, and low cost, makes this method a promising imaging technique for the lungs.

Animals↗

Short planar gradient coils for MR microscopy using concentric return paths.

The aim of this work is to design a set of gradient coils with an optimal geometry for magnetic resonance microscopy studies. Designs for a three-axis gradient coil system particularly suited for studies with small radiofrequency coils are presented. The novel geometry involves a planar section with concentric return paths to keep the coil short. Reduction of the external field has been attempted by varying the positions of the return paths using a simulated annealing algorithm. A biplanar version of x- and z-directed prototype gradients was built and tested. A 2D-MR image of a grid phantom has been obtained on a 7-T MR instrument to demonstrate the theory. A three-axis set used as a surface gradient set has also been built and used to obtain high-resolution MR images.

Equipment Design↗

In vivo detection of acute rat renal allograft rejection by MRI with USPIO particles.

BACKGROUND: Magnetic resonance imaging (MRI) for non-invasively detecting renal rejection was developed by monitoring the accumulation of macrophages labeled with dextran-coated ultrasmall superparamagnetic iron oxide (USPIO) particles at the rat renal allografts during acute rejection. METHODS: Five groups of male rats with DA-->BN renal allografts and one group with BN-->BN renal isografts were investigated by MRI before, immediately after, and 24 hr after intravenous infusion with different doses of USPIO particles. All infusions were done on post-operative day 4. MRI experiments were carried out in a 4.7-Tesla instrument using a gradient echo sequence. RESULTS: MR signal intensity (MRSI) of the cortex was found to decrease with higher dosages of USPIO particles. In the absence of USPIO infusion, a decrease in MRSI was seen in the medulla region, presumably due to hemorrhage associated with renal graft rejection, while no significant change was observed in the cortex. The optimal dose of USPIO particles for visualizing rejection-associated changes in our rat kidney model appears to be 6 mg Fe/kg body weight. Iron staining results correlated with the MRSI data, indicating that the signal reduction in the MR images was due to the presence of iron. Immunohistochemical results indicated that USPIO particles were mostly taken up by infiltrating macrophages in the rejecting grafts. CONCLUSIONS: Our results suggest that MRI with intravenous administration of dextran-coated USPIO particles appears to be a valuable and promising tool that can be used as a non-invasive and sensitive method to detect graft rejection in renal transplantation.

Acute Disease↗

Cerebral blood flow at one year after controlled cortical impact in rats: assessment by magnetic resonance imaging.

Progressive tissue loss and delayed cognitive deficits are seen in rats during the initial year after experimental traumatic brain injury (TBI). As much as 10% of parenchymal volume is lost even in the contralateral hemisphere by 1 year after controlled cortical impact (CCI) in rats. Progressive declines in cerebral blood flow (CBF) are also associated with advanced age and neurodegenerative diseases. Surprisingly, the long-term effects of TBI on CBF remain undefined. CBF was quantified by continuous arterial spin-labeled magnetic resonance imaging (MRI) and measurements of spin-lattice relaxation time in a slice through the plane of injury at 1 year after experimental TBI produced by CCI (n = 4) or sham surgery (n = 4) in rats. CBF was quantified in six regions of interest (ROIs) that were anatomically identified on the control images in each hemisphere and included a medial cortical segment (contusion-enriched, beneath the impact site, on the ipsilateral side) cortex, hippocampus, thalamus, amygdala/pyriform cortex, and hemisphere. At 1 year after injury, CBF was dramatically (96%) reduced in structures within the large cystic lesion that was seen in three of four rats and variably included cortex and hippocampus. Overall, there was an 80% reduction in CBF in the ipsilateral medial cortical segment comparing CCI and sham groups. Similarly, 52% and 67% reductions were seen in CBF in the cortical and hippocampal ROIs ipsilateral to impact (CCI vs. sham), respectively. These are regions both with marked CBF disturbances early after injury and that ultimately suffer considerable tissue loss over the 1-year interval. However, at 1 year after CCI, CBF was not different from sham in other ROIs, including ipsilateral thalamus, or either contralateral hippocampus or hemisphere. We conclude that, at 1 year after CCI, CBF is reduced in anatomic structures at or near the impact site, including injured cortex and hippocampus, and this translates into a reduction in hemispheric CBF. However, despite both significant occult tissue loss ipsilateral and contralateral to the injury and delayed cognitive deficits, widespread reductions in CBF are not observed. This suggests the possibility of remodeling or repackaging of the brain that preserves CBF outside of the cystic lesion.

Animals↗