Search PubMed⌕ Search

Biomedical subjects

Cheng S Lee

Publications and source records attributed to Cheng S Lee.

At least 19 recordsLinked to original sources

Selective enrichment and ultrasensitive identification of trace peptides in proteome analysis using transient capillary isotachophoresis/zone electrophoresis coupled with nano-ESI-MS.

Besides the complexity in protein samples of biological origin, probably the greatest challenge presently facing comprehensive proteome analysis is related to the large variation of protein relative abundances (>6 orders of magnitude), having potential biological significance in mammalian systems. As demonstrated in this work, transient capillary ITP/zone electrophoresis (CITP/CZE) provides selective analyte enrichment through electrokinetic stacking and extremely high resolving power toward protein and peptide mixtures. The result of the CITP process is that major components may be diluted, but trace compounds are concentrated. The on-column transition of CITP to CZE minimizes additional band broadening while providing superior analyte resolution. Online coupling of transient CITP/CZE with nano-ESI-MS allows ultrasensitive detection of trace peptides at levels of subnanomolar concentration or subfemtomole mass in complex peptide mixtures. More importantly, selective enrichment of trace peptides enables the identification and sequence analysis of low-abundance peptides co-migrated with highly abundant species at a concentration ratio of 1:500,000. The combined CITP/CZE-nano-ESI-MS system is demonstrated to be at least one to two orders of magnitude more sensitive than that attained in conventional electrophoretic and chromatographic-based proteome technologies over a wide dynamic concentration range, potentially allowing comprehensive analysis of protein profiles within a small cell population and limited tissue samples using conventional mass spectrometers. Furthermore, the speed of CITP/CZE separation and the lack of column equilibration in CITP/CZE not only improve the throughput of proteome analysis, but also facilitate its seamless integration with other separation technologies in a multidimensional protein identification platform.

Cytochromes c↗

Capillary separations enabling tissue proteomics-based biomarker discovery.

Development of the capability to enable large-scale proteome studies, analogous to comprehensive gene expression analysis, will clearly have far-reaching impacts on protein biomarker investigations of human diseases such as cancer through interrogation of the archived fresh frozen and formalin-fixed and paraffin-embedded tissue collections. This review therefore focuses on the most recent advances in microdissection techniques and proteome platforms for procuring homogeneous subpopulations of tumor cells or structures and performing comprehensive analysis of protein profiles within tissue specimens, respectively. Developments in capillary separations capable of providing extremely high resolving power and selective analyte enrichment are particularly highlighted for their roles within the broader context of a state-of-the-art integrated tissue proteome effort. The capabilities of CIEF-based multidimensional separations for performing proteome analysis from minute samples create new opportunities in the pursuit of biomarker discovery using enriched and selected cell populations procured from tissue specimens. These proteome technological advances combined with recently developed tissue microdissection techniques provide powerful tools for those seeking to gain a greater understanding at the global level of the cellular machinery associated with human diseases such as cancer.

Biomarkers↗

Microfluidic technologies for MALDI-MS in proteomics.

The field of microfluidics continues to offer great promise as an enabling technology for advanced analytical tools. For biomolecular analysis, there is often a critical need to couple on-chip microfluidic sample manipulation with back-end MS. Though interfacing microfluidics to MS has been most often reported through the use of direct ESI-MS, there are compelling reasons for coupling microfluidics to MALDI-MS as an alternative to ESI-MS for both online and offline analysis. The intent of this review is to provide a summary of recent developments in the integration of microfluidic systems with MALDI-MS, with an emphasis on applications in proteomics. Key points are summarized, followed by a review of relevant technologies and a discussion of outlook for the field.

Microfluidics↗

Characterization of the human salivary proteome by capillary isoelectric focusing/nanoreversed-phase liquid chromatography coupled with ESI-tandem MS.

Saliva is a readily available body fluid with great diagnostic potential. The foundation for saliva-based diagnostics, however, is the development of a complete catalog of secreted and "leaked" proteins detectable in saliva. By employing a capillary isoelectric focusing-based multidimensional separation platform coupled with electrospray ionization tandem mass spectrometry (MS), a total of 5338 distinct peptides were sequenced, leading to the identification of 1381 distinct proteins. A search of bacterial protein sequences also identified many peptides unique to several organisms and unique to the NCBI nonredundant database. To the best of our knowledge, this proteome study represents the largest catalog of proteins measured from a single saliva sample to date. Data analysis was performed on individual MS/MS spectra using the highly specific peptide identification algorithm, OMSSA. Searches were conducted against a decoyed SwissProt human database to control the false-positive rate at 1%. Furthermore, the well-curated SwissProt sequences represent perhaps the least redundant human protein sequence database (12,484 records versus the 50,009 records found in the International Protein Index human database), therefore minimizing multiple protein inferences from single peptides. This combined bioanalytical and bioinformatic approach has established a solid foundation for building up the human salivary proteome for the realization of the diagnostic potential of saliva.

Chromatography, Liquid↗

Proteome analysis of microdissected tumor tissue using a capillary isoelectric focusing-based multidimensional separation platform coupled with ESI-tandem MS.

This study demonstrates the ability to perform sensitive proteome analysis on the limited protein quantities available through tissue microdissection. Capillary isoelectric focusing combined with nano-reversed-phase liquid chromatography in an automated and integrated platform not only provides systematic resolution of complex peptide mixtures based on their differences in isoelectric point and hydrophobicity but also eliminates peptide loss and analyte dilution. In comparison with strong cation exchange chromatography, the significant advantages of electrokinetic focusing-based separations include high resolving power, high concentration and narrow analyte bands, and effective usage of electrospray ionization-tandem MS toward peptide identifications. Through the use of capillary isoelectric focusing-based multidimensional peptide separations, a total of 6866 fully tryptic peptides were detected, leading to the identification of 1820 distinct proteins. Each distinct protein was identified by at least one distinct peptide sequence. These high mass accuracy and high-confidence identifications were generated from three proteome runs of a single glioblastoma multiforme tissue sample, each run consuming only 10 microg of total protein, an amount corresponding to 20,000 selectively isolated cells. Instead of performing multiple runs of multidimensional separations, the overall peak capacity can be greatly enhanced for mining deeper into tissue proteomics by increasing the number of CIEF fractions without an accompanying increase in sample consumption.

Brain Neoplasms↗

Effects of chromatography conditions on intact protein separations for top-down proteomics.

For top-down proteomics, nano-reversed phase liquid chromatography (RPLC) plays a major role in both single and multidimensional protein separations in an effort to increase the overall peak capacity for the resolution of complex protein mixtures prior to mass spectrometry analysis. Effects of various chromatography conditions, including alkyl chain length in the stationary phase, capillary column temperature, and ion-pairing agent, on the resolution of intact proteins are studied using nano-RPLC-electrospray ionization-mass spectrometry. Optimal chromatography conditions include the use of C18 column heated at 60 degrees C and the addition of trifluoroacetic acid instead of heptafluorobutyric acid as the ion-paring agent in the mobile phase. Under optimized chromatography conditions, there are no significant differences in the separation performance of yeast cell lysates present in the native versus denatured states. Denatured yeast proteins resolved and eluted from nano-RPLC can be subjected to proteolytic digestion in an on- or off-line approach to provide improved protein sequence coverage toward protein identification in a combined top-down/bottom-up proteome platform.

Chromatography, High Pressure Liquid↗

Polymer nanochannels fabricated by thermomechanical deformation for single-molecule analysis.

A simple method for fabricating nanoscale channels based on thermomechanical deformation of rigid polymer substrates is demonstrated. Polycarbonate preforms containing microchannels with cross-sectional dimensions on the order of tens of micrometers are controllably deformed to produce submicrometer dimensions. The reduced channel dimensions are achieved by heating the preform while applying a uniaxial tensile force to reduce channel cross sections through the Poisson effect. Nanochannels with circular or elliptical cross sections are defined by varying the channel position and preform geometry prior to deformation. Arrays of parallel nanochannels with critical dimensions down to 400 nm are described. Using the fabrication method, a nanochannel network is fabricated for the detection of single protein molecules via confocal fluorescence microscopy. The chip includes a detection channel with cross-sectional dimensions approaching the confocal volume dimensions of the detection optics and a larger adjacent reference channel used to optimize focusing. Detection of fluorescently labeled bovine serum albumin at 15 and 150 nM concentrations is presented, demonstrating the ability to perform single-molecule fluorescence measurements in polycarbonate chips using visible wavelengths for excitation and detection.

Chemistry Techniques, Analytical↗

Denaturing gradient-based two-dimensional gene mutation scanning in a polymer microfluidic network.

An integrated two-dimensional (2-D) DNA separation platform, combining standard gel electrophoresis with temperature gradient gel electrophoresis (TGGE) on a polymer microfluidic chip, is reported. Rather than sequentially sampling DNA fragments eluted from standard gel electrophoresis, size-resolved fragments are simultaneously electrokinetically transferred into an array of orthogonal microchannels and screened for the presence of sequence heterogeneity by TGGE in a parallel and high throughput format. A bulk heater assembly is designed and employed to externally generate a temporal temperature gradient along an array of TGGE channels. Extensive finite element modeling is performed to determine the optimal geometries of the microfluidic network for minimizing analyte band dispersion caused by interconnected channels in the network. A pH-mediated on-chip analyte stacking strategy is employed prior to the parallel TGGE separations to further reduce additional band broadening acquired during the electrokinetic transfer of DNA fragments between the first and second separation dimensions. A comprehensive 2-D DNA separation is completed in less than 5 min for positive detection of single-nucleotide polymorphisms in multiplex PCR products that vary in size and sequence.

DNA↗

Electrospray interfacing of polymer microfluidics to MALDI-MS.

The off-line coupling of polymer microfluidics to MALDI-MS is presented using electrospray deposition. Using polycarbonate microfluidic chips with integrated hydrophobic membrane electrospray tips, peptides and proteins are deposited onto a stainless steel target followed by MALDI-MS analysis. Microchip electrospray deposition is found to yield excellent spatial control and homogeneity of deposited peptide spots, and significantly improved MALDI-MS spectral reproducibility compared to traditional target preparation methods. A detection limit of 3.5 fmol is demonstrated for angiotensin. Furthermore, multiple electrospray tips on a single chip provide the ability to simultaneously elute parallel sample streams onto a MALDI target for high-throughput multiplexed analysis. Using a three-element electrospray tip array with 150 microm spacing, the simultaneous deposition of bradykinin, fibrinopeptide, and angiotensin is achieved with no cross talk between deposited samples. In addition, in-line proteolytic digestion of intact proteins is successfully achieved during the electrospray process by binding trypsin within the electrospray membrane, eliminating the need for on-probe digestion prior to MALDI-MS. The technology offers promise for a range of microfluidic platforms designed for high-throughput multiplexed proteomic analyses in which simultaneous on-chip separations require an effective interface to MS.

Microfluidic Analytical Techniques↗

Tissue proteomics using capillary isoelectric focusing-based multidimensional separations.

The capabilities of capillary isoelectric focusing-based multidimensional separations for performing proteome analysis from minute samples create new opportunities in the pursuit of biomarker discovery using enriched and selected cell populations procured from tissue specimens. In this article, recent advances in online integration of capillary isoelectric focusing with nano-reversed phase liquid chromatography for achieving high-resolution peptide and protein separations prior to mass spectrometry analysis are reviewed, along with its potential application to tissue proteomics. These proteome technological advances combined with recently developed tissue microdissection techniques, provide powerful tools for those seeking to gain a greater understanding at the global level of the cellular machinery associated with human diseases such as cancer.

Electrophoresis, Capillary↗

Efficient electrospray ionization from polymer microchannels using integrated hydrophobic membranes.

A simple process for realizing stable and reliable electrospray ionization (ESI) tips in polymer microfluidic systems is described. The process is based on the addition of a thin hydrophobic membrane at the microchannel exit to constrain lateral dispersion of the Taylor cone formed during ESI. Using this approach, ESI chips are shown to exhibit well-defined Taylor cones at flow rates as low as 80 nL min(-1) through optical imaging. Furthermore, stable electrospray current has been measured for flow rates as low as 10 nL min(-1) over several hours of continuous operation. Characterization of the electrospray process by optical and electrical monitoring of fabricated ESI chips is reported, together with mass spectrometry validation using myoglobin as a model protein. The novel process offers the potential for low-cost, direct interfacing of disposable polymer microfluidic separation platforms to mass spectrometry.

Membrane Proteins↗

Integrated and ultrasensitive gel protein identification.

An integrated gel protein identification technology is developed and demonstrated for the effective ( approximately 90% recovery), rapid (less than 5 min), and sensitive identification (as low as 1 ng gel protein loading) of gel-resolved proteins using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). This integrated technology involves on-line combination of electronic protein transfer with nanoscale proteolytic digestion in a capillary platform, enabling electrokinetic-based protein extraction and stacking, real-time proteolytic cleavage of extracted proteins, and direct deposition of protein digests onto MALDI targets. By revisiting the yeast two-dimensional polyacrylamide gel electrophoresis (2-D PAGE) in similar isoelectric point and molecular mass ranges as studied by Gygi and co-workers (Gygi, S. P.; Corthals, G. L.; Zhang, Y.; Rochon, Y.; Aebersold, R. Proc. Natl. Acad. Sci. U.S.A. 2000, 97, 9390-9395), we are additionally able to identify a large number of low abundance proteins with codon adaptation index (CAI) values of <0.2 and increase the proteome coverage to nearly 50%. The CAI value distribution for identified yeast proteins now more closely approximates that predicted for the entire yeast proteome. We further note that the current single-capillary methodology can be easily expanded to a multiplexed capillary platform as a ultrahigh throughput and greatly effective tool for linking 2-D PAGE with MS, particularly for the analysis of low-abundance proteins.

Electrophoresis, Gel, Two-Dimensional↗

Induced pressure pumping in polymer microchannels via field-effect flow control.

Microfluidic field-effect flow control (FEFC) modifies the zeta potential of electroosmotic flow using a transverse electric field applied through the microchannel wall. Previously demonstrated in silicon-based and glass microsystems, FEFC is presented here as an elegant method for flow control in polymer-based microfluidics with a simple and low-cost fabrication process. In addition to direct FEFC flow modulation, independent transverse electric fields in connected microchannels are demonstrated to produce a differential pumping rate between the microchannels. The different electroosmotic pumping rates formed by local zeta potential control induce an internal pressure at the microchannel intersection, resulting in hydrodynamic pumping through an interconnecting field-free microchannel. Modulation of the voltages applied to the gate electrodes adjusts the magnitude and direction of the bidirectional pressure pumping, with fine resolution volume flow rates from -2 to 2 nL/min in the field-free microchannel demonstrated.

Journal Article↗

DNA mutation detection in a polymer microfluidic network using temperature gradient gel electrophoresis.

A miniaturized system for DNA mutation analysis, utilizing temperature gradient gel electrophoresis (TGGE) in a polycarbonate (PC) microfluidic device, is reported. TGGE reveals the presence of sequence heterogeneity in a given heteroduplex sample by introducing a thermal denaturing gradient that results in differences between the average electrophoretic mobilities of DNA sequence variants. Bulk heater assemblies are designed and employed to externally generate temperature gradients in spatial and temporal formats along the separation channels. TGGE analyses of model mutant DNA fragments, each containing a single base substitution, are achieved using both single- and 10-channel parallel measurements in a microfluidic platform. Additionally, a comprehensive polymer microfluidic device containing an integrated microheater and sensor array is developed and demonstrated for performing spatial TGGE for DNA mutation analysis. The device consists of two PC modular substrates mechanically bonded together. One substrate is embossed with microchannels, and the other contains a tapered microheater, lithographically patterned along with an array of temperature sensors. Compared with the external heating approaches, the integrated platform provides significant reduction in power requirement and thermal response time while establishing more accurate and highly effective control of the temperature gradient for achieving improved separation resolution.

DNA Mutational Analysis↗

Integration of isoelectric focusing with parallel sodium dodecyl sulfate gel electrophoresis for multidimensional protein separations in a plastic microfluidic [correction of microfludic] network.

An integrated protein concentration/separation system, combining non-native isoelectric focusing (IEF) with sodium dodecyl sulfate (SDS) gel electrophoresis on a polymer microfluidic chip, is reported. The system provides significant analyte concentration and extremely high resolving power for separated protein mixtures. The ability to introduce and isolate multiple separation media in a plastic microfluidic network is one of two key requirements for achieving multidimensional protein separations. The second requirement lies in the quantitative transfer of focused proteins from the first to second separation dimensions without significant loss in the resolution acquired from the first dimension. Rather than sequentially sampling protein analytes eluted from IEF, focused proteins are electrokinetically transferred into an array of orthogonal microchannels and further resolved by SDS gel electrophoresis in a parallel and high-throughput format. Resolved protein analytes are monitored using noncovalent, environment-sensitive, fluorescent probes such as Sypro Red. In comparison with covalently labeling proteins, the use of Sypro staining during electrophoretic separations not only presents a generic detection approach for the analysis of complex protein mixtures such as cell lysates but also avoids additional introduction of protein microheterogeneity as the result of labeling reaction. A comprehensive 2-D protein separation is completed in less than 10 min with an overall peak capacity of approximately 1700 using a chip with planar dimensions of as small as 2 cm x 3 cm. Significant enhancement in the peak capacity can be realized by simply raising the density of microchannels in the array, thereby increasing the number of IEF fractions further analyzed in the size-based separation dimension.

Electrophoresis, Gel, Two-Dimensional↗

Electronic gel protein transfer and identification using matrix-assisted laser desorption/ionization-mass spectrometry.

An electronic protein transfer technique is described for achieving the rapid and efficient recovery of sodium dodecyl sulfate (SDS)-protein complexes from polyacrylamide gels. This process involves the use of small-dimension capillaries in physical contact with a resolved protein band within the polyacrylamide gel, providing a large potential drop and high electric field strength at the capillary/gel interface. Several factors controlling the electronic protein transfer, including the applied electric field strength, the electrophoresis buffer concentration, and the capillary dimension, are studied to further enhance the use of field-amplification for sample stacking of extracted SDS-protein complexes. As a result of sample stacking, the extracted proteins from a 50 ng gel loading are present in a narrow ( approximately 80 nL) and highly concentrated (0.46 mg/mL or 3.3 x 10(-5) M for cytochrome c) solution plug. Three model proteins with molecular mass ranging from 14 kDa (cytochrome c) to 116 kDa (beta-galactosidase) are stained by Coomassie blue and electrophoretically extracted from gels with protein loadings as low as 50 ng. The capillary format of the electronic protein transfer technique allows direct deposition of extracted proteins onto a matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) target. Various matrices and solvent compositions are evaluated for the analysis of extracted and concentrated SDS-protein complexes using MALDI-MS. The electronic protein transfer technique, when operated under optimized conditions, is demonstrated for the effective (>70% recovery), speedy (less than 5 min), and sensitive MS identification of gel resolved proteins (as low as 50 ng).

Cytochromes c↗

Recent advances in capillary separations for proteomics.

The sequencing of several organisms' genomes, including the human's one, has opened the way for the so-called postgenomic era, which is now routinely coined as "proteomics". The most basic task in proteomics remains the detection and identification of proteins from a biological sample, and the most traditional way to achieve this goal consists of protein separations performed by two-dimensional polyacrylamide gel electrophoresis (2-D PAGE). Still, the 2-D PAGE-mass spectrometry (MS) approach remains lacking in proteome coverage (for proteins having extreme isoelectric points or molecular masses as well as for membrane proteins), dynamic range, sensitivity, and throughput. Consequently, considerable efforts have been devoted to the development of non-gel-based proteome separation technologies in an effort to alleviate the shortcomings in 2-D PAGE while reserving the ability to resolve complex protein and peptide mixtures prior to MS analysis. This review focuses on the most recent advances in capillary-based separation techniques, including capillary liquid chromatography, capillary electrophoresis, and capillary electrokinetic chromatography, and combinations of multiples of these mechanisms, along with the coupling of these techniques to MS. Developments in capillary separations capable of providing extremely high resolving power and selective analyte enrichment are particularly highlighted for their roles within the broader context of a state-of-the-art integrated proteome effort. Miniaturized and integrated multidimensional peptide/protein separations using microfluidics are further summarized for their potential applications in high-throughput protein profiling toward biomarker discovery and clinical diagnosis.

Chromatography, Liquid↗

Integration of electrokinetic-based multidimensional separation/concentration platform with electrospray ionization-Fourier transform ion cyclotron resonance-mass spectrometry for proteome analysis of Shewanella oneidensis.

This work focuses on the development of a multidimensional electrokinetic-based separation/concentration platform coupled with electrospray ionization-Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICR-MS) for achieving the high resolution and ultrasensitive analysis of complex protein/peptide mixtures. A microdialysis junction is employed as the interface for on-line combination of capillary isoelectric focusing (CIEF) with transient capillary isotachophoresis/zone electrophoresis (CITP/CZE) in an integrated platform. Besides the excellent resolving power afforded by both CIEF and CZE separations, the electrokinetic focusing/stacking effects of CIEF and CITP greatly enhance the dynamic range and detection sensitivity of MS for protein identification. The constructed multidimensional separation/concentration platform is demonstrated for the analysis of Shewanella oneidensis proteome, which has considerable implications toward the bioremediation of environmental pollutants. The electrokinetic-based platform offers the overall peak capacity comparable to those obtained using multidimensional chromatography systems, but with a much shorter run time and no need for column regeneration. Most importantly, a total of 1174 unique proteins, corresponding to 26.5% proteome coverage, are identified from the cytosolic fraction of S. oneidensis, while requiring <500 ng of proteolytic digest loaded in the CIEF capillary. The ultrasensitive capabilities of electrokinetic-based proteome approach are attributed to the concentration effect in CIEF, the electrokinetic stacking of CITP, the nanoscale peak volume in CZE, the "accurate mass tag" strategy for protein/peptide identification, and the high-sensitivity, high-resolution, and high-mass measurement accuracy of FTICR-MS.

Amino Acid Sequence↗