Improved transverse flow estimation using differential maximum Doppler frequency.

Conventional Doppler technique can only provide the axial component of the blood flow vector, which is actually a three dimensional (3-D) quantity. To acquire the complete flow vector, estimations of the other two velocity components are essential. For the two dimensional (2-D) Doppler-bandwidth-based transverse estimation, however, accuracy is generally limited because of the complex dependence of the Doppler spectral shape on the flow variation within the sample volume. Two factors that may lead to the Doppler spectral change were considered in this study. One is the position offset of the sample volume and the other is the length of the sample volume. Simulations were performed and experimental data were also collected. Results indicate that the position offset may result in severe underestimation of Doppler shift frequency. Consequently, Doppler bandwidth is overestimated when it is determined by the difference between Doppler shift frequency and maximum Doppler frequency. Compared with the position offset, influence of the length of sample volume on the Doppler bandwidth is minor. To overcome this problem, a novel method, which is based on the differential maximum Doppler frequency, is proposed. Specifically, two beams with different beam widths are simultaneously generated to observe the blood flow and the difference between the corresponding maximum Doppler frequencies is used to estimate the transverse velocity. It is demonstrated that the accuracy and stability of transverse estimation are significantly improved by the proposed method even when the position offset is present.

Blood Flow Velocity↗

Waveform design for ultrasonic pulse-inversion fundamental imaging.

Pulse-inversion (PI) fundamental imaging exhibits significantly better contrast detection than linear and second-harmonic imaging. PI fundamental imaging involves two firings with inverted waveforms. When the returning echoes from the two firings are summed, the residual signal related to tissue is limited to even-order harmonics, whereas for microbubbles, the fundamental signal is not completely canceled due to the echo under compression differing from that under rarefaction. The efficacy of PI fundamental imaging has been reported previously. In this study, we investigated the performance of PI fundamental imaging using both simulations and in vitro experiments with various transmit waveforms, including coded excitation and asymmetrical waveforms (i.e., asymmetrical between compression and rarefaction). For coded excitation, a longer waveform was found to increase the similarity in the responses to positive and negative pulses, thus lowering the contrast between microbubbles and tissue. In addition, imperfect pulse compression also decreases the contrast because it increases the residue fundamental signal emanating from tissue. Using asymmetrical waveforms noticeably increased the residual microbubble signal in the fundamental band but the nonzero DC component that is inherent in such waveforms also increases the tissue fundamental signal. The combination of these two effects decreases the contrast. From these results, it is concluded that the use of coded excitation is undesirable in PI fundamental imaging and that the waveforms should contain no DC component. Furthermore, the transmit waveform needs to be appropriately windowed in order to reduce spectral leakage. Therefore, a Gaussian pulse with the pulse length determined by the signal-to-noise ratio of the imaging system is generally optimal for PI fundamental imaging.

Artifacts↗

Pulse-inversion-based fundamental imaging for contrast detection.

Pulse-inversion-based fundamental imaging was experimentally investigated for the enhancement of contrast detection. The pulse-inversion technique involves two firings with inverted waveforms. When the returning echoes from the two firings are summed, the residue signal is limited to even-order harmonics for tissue. However, when the returning echoes are from microbubbles, the fundamental signal is not completely cancelled because the reaction of the bubbles under compression is different from that under rarefaction. Thus, with the application of pulse-inversion technique, the fundamental signal can be used to enhance the contrast-to-tissue ratio. In this paper, B-mode, pulse-inversion-based fundamental images were constructed with various transmit waveforms. Motion artifacts also were studied. The results indicate that the contrast-to-tissue ratio was significantly enhanced compared to that obtained using either conventional, fundamental imaging or second-harmonic imaging. Longer transmit pulses resulted in a better signal-to-noise ratio, but did not noticeably affect the nonlinear response of the bubbles. In addition, the optimal ratio of the magnitude of the positive pulse to that of the negative pulse was unity, in terms of avoiding the uncancelled, third-order response in the fundamental frequency range. It also was found that the pulse-inversion fundamental technique is highly sensitive to tissue motion because the fundamental tissue signal is not cancelled when motion is present.

Artifacts↗

Motion artifacts of pulse inversion-based tissue harmonic imaging.

Motion artifacts of the pulse inversion technique were studied for finite amplitude distortion-based harmonic imaging. Motion in both the axial and the lateral directions was considered. Two performance issues were investigated. One is the harmonic signal intensity relative to the fundamental intensity and the other is the potential image quality degradation resulting from spectral leakage. A one-dimensional (1-D) correlation-based correction scheme also was used to compensate for motion artifacts. Results indicated that the tissue harmonic signal is significantly affected by tissue motion. For axial motion, the tissue harmonic intensity decreases much more rapidly than with lateral motion. The fundamental signal increases for both axial and lateral motion. Thus, filtering is still required to remove the fundamental signal, even if the pulse inversion technique is applied. The motion also potentially decreases contrast resolution because of the uncancelled spectral leakage. Also, it was indicated that 1-D motion correction is not adequate if nonaxial motion is present.

Artifacts↗