Workgroup report: Indoor chemistry and health.

Chemicals present in indoor air can react with one another, either in the gas phase or on surfaces, altering the concentrations of both reactants and products. Such chemistry is often the major source of free radicals and other short-lived reactive species in indoor environments. To what extent do the products of indoor chemistry affect human health? To address this question, the National Institute for Occupational Safety and Health sponsored a workshop titled "Indoor Chemistry and Health" on 12-15 July 2004 at the University of California-Santa Cruz. Approximately 70 experts from eight countries participated. Objectives included enhancing communications between researchers in indoor chemistry and health professionals, as well as defining a list of priority research needs related to the topic of the workshop. The ultimate challenges in this emerging field are defining exposures to the products of indoor chemistry and developing an understanding of the links between these exposures and various health outcomes. The workshop was a step toward meeting these challenges. This summary presents the issues discussed at the workshop and the priority research needs identified by the attendees.

Air Pollutants↗

Products of ozone-initiated chemistry in a simulated aircraft environment.

We used proton-transfer-reaction mass spectrometry (PTR-MS) to examine the products formed when ozone reacted with the materials in a simulated aircraft cabin, including a loaded high-efficiency particulate air (HEPA) filter in the return air system. Four conditions were examined: cabin (baseline), cabin plus ozone, cabin plus soiled T-shirts (surrogates for human occupants), and cabin plus soiled T-shirts plus ozone. The addition of ozone to the cabin without T-shirts, at concentrations typically encountered during commercial air travel, increased the mixing ratio (v:v concentration) of detected pollutants from 35 ppb to 80 ppb. Most of this increase was due to the production of saturated and unsaturated aldehydes and tentatively identified low-molecular-weight carboxylic acids. The addition of soiled T-shirts, with no ozone present, increased the mixing ratio of pollutants in the cabin air only slightly, whereas the combination of soiled T-shirts and ozone increased the mixing ratio of detected pollutants to 110 ppb, with more than 20 ppb originating from squalene oxidation products (acetone, 4-oxopentanal, and 6-methyl-5-hepten-2-one). For the two conditions with ozone present, the more-abundant oxidation products included acetone/propanal (8-20 ppb), formaldehyde (8-10 ppb), nonanal (approximately 6 ppb), 4-oxopentanal (3-7 ppb), acetic acid (approximately 7 ppb), formic acid (approximately 3 ppb), and 6-methyl-5-hepten-2-one (0.5-2.5 ppb), as well as compounds tentatively identified as acrolein (0.6-1 ppb) and crotonaldehyde (0.6-0.8 ppb). The odor thresholds of certain products were exceeded. With an outdoor air exchange of 3 h(-1) and a recirculation rate of 20 h(-1), the measured ozone surface removal rate constant was 6.3 h(-1) when T-shirts were not present, compared to 11.4 h(-1) when T-shirts were present.

Air Pollution, Indoor↗

Nasal effects of a mixture of volatile organic compounds and their ozone oxidation products.

OBJECTIVE: Our objective was to determine if low levels of a mixture of volatile organic compounds (VOCs) and their ozone (O3) oxidation products, similar to what might be found in "sick buildings," cause nasal irritation and inflammation under controlled exposure conditions. METHODS: Healthy, nonsmoking women (n=130) completed 2-hour controlled exposures to VOCs, VOCs and O3, and a masked air "MA" control in random order at least 1 week apart. VOCs and O3 concentrations were approximately 25 mg/m and approximately 40 ppb, respectively. Nasal symptoms were rated before, during, and after exposure. Nasal lavage fluid was analyzed for polymorphonuclear cells, total protein, interleukin-6, and interleukin-8. RESULTS: We found no significant differences in symptoms or markers of nasal inflammation between exposure conditions. CONCLUSIONS: Results suggest that VOCs and their oxidation products may not cause acute nasal effects at low concentrations.

Adult↗

Phthalates in indoor dust and their association with building characteristics.

In a recent study of 198 Swedish children with persistent allergic symptoms and 202 controls without such symptoms, we reported associations between the symptoms and the concentrations of n-butyl benzyl phthalate (BBzP) and di(2-ethylhexyl) phthalate (DEHP) in dust taken from the childrens' bedrooms. In the present study we examined associations between the concentrations of different phthalate esters in the dust from these bedrooms and various characteristics of the home. The study focused on BBzP and DEHP because these were the phthalates associated with health complaints. Associations have been examined using parametric and nonparametric tests as well as multiple logistic regression. For both BBzP and DEHP, we found associations between their dust concentrations and the amount of polyvinyl chloride (PVC) used as flooring and wall material in the home. Furthermore, high concentrations of BBzP (above median) were associated with self-reported water leakage in the home, and high concentrations of DEHP were associated with buildings constructed before 1960. Other associations, as well as absence of associations, are reported. Both BBzP and DEHP were found in buildings with neither PVC flooring nor wall covering, consistent with the numerous additional plasticized materials that are anticipated to be present in a typical home. The building characteristics examined in this study cannot serve as complete proxies for these quite varied sources. However, the associations reported here can help identify homes where phthalate concentrations are likely to be elevated and can aid in developing mitigation strategies.

Case-Control Studies↗

Indoor fine particles: the role of terpene emissions from consumer products.

Consumer products can emit significant quantities of terpenes, which can react with ozone (O3). Resulting byproducts include compounds with low vapor pressures that contribute to the growth of secondary organic aerosols (SOAs). The focus of this study was to evaluate the potential for SOA growth, in the presence of O3, following the use of a lime-scented liquid air freshener, a pine-scented solid air freshener, a lemon-scented general-purpose cleaner, a wood floor cleaner, and a perfume. Two chamber experiments were performed for each of these five terpene-containing agents, one at an elevated O3 concentration and-the other at a lower O3 concentration. Particle number and mass concentrations increased and O3 concentrations decreased during each experiment. Experiments with terpene-based air fresheners produced the highest increases in particle number and mass concentrations. The results of this study clearly demonstrate that homogeneous reactions between O3 and terpenes from various consumer products can lead to increases in fine particle mass concentrations when these products are used indoors. Particle increases can occur during periods of elevated outdoor O3 concentrations or indoor O3 generation, coupled with elevated terpene releases. Human exposure to fine particles can be reduced by minimizing indoor terpene concentrations or O3 concentrations.

Air Pollution, Indoor↗

The association between asthma and allergic symptoms in children and phthalates in house dust: a nested case-control study.

Global phthalate ester production has increased from very low levels at the end of World War II to approximately 3.5 million metric tons/year. The aim of the present study was to investigate potential associations between persistent allergic symptoms in children, which have increased markedly in developed countries over the past three decades, and the concentration of phthalates in dust collected from their homes. This investigation is a case-control study nested within a cohort of 10,852 children. From the cohort, we selected 198 cases with persistent allergic symptoms and 202 controls without allergic symptoms. A clinical and a technical team investigated each child and her or his environment. We found higher median concentrations of butyl benzyl phthalate (BBzP) in dust among cases than among controls (0.15 vs. 0.12 mg/g dust). Analyzing the case group by symptoms showed that BBzP was associated with rhinitis (p = 0.001) and eczema (p = 0.001), whereas di(2-ethylhexyl) phthalate (DEHP) was associated with asthma (p = 0.022). Furthermore, dose-response relationships for these associations are supported by trend analyses. This study shows that phthalates, within the range of what is normally found in indoor environments, are associated with allergic symptoms in children. We believe that the different associations of symptoms for the three major phthalates-BBzP, DEHP, and di-n-butyl phthalate-can be explained by a combination of chemical physical properties and toxicologic potential. Given the phthalate exposures of children worldwide, the results from this study of Swedish children have global implications.

Air Pollution, Indoor↗

Indoor hydrogen peroxide derived from ozone/d-limonene reactions.

In this pilot study, performed in an office manipulated to resemble an environment with a strong indoor ozone source or a significant influx of outdoor air during a smog event, reactions between ozone and d-limonene produced hydroperoxides. Hydrogen peroxide (H202) presumably constituted the majority of the measured hydroperoxides, although a small amount of organic hydroperoxides (ROOH) may have contributed to the signal. Total hydroperoxides were 1.0-1.5 ppb at low air exchange rates (0.5-4 h(-1)) and 0.6-0.8 ppb at high air exchange rates (12-18 h-1). The net estimated yield ranged from 1.5 to 3.2%, consistent with values reported in the literature. Based on these yields and typical indoor scenarios, peak indoor concentrations of H202 are projected to be comparable with, but not significantly larger than, peak outdoor concentrations. Hygroscopic secondary organic aerosols (SOA; 10-100 microg m(-3)) were simultaneously generated by the ozone/d-limonene reactions; their co-occurrence with H202 provides a mechanism whereby H2O2 can be transported into the lower respiratory tract. The results demonstrate that reduced air exchange rates lead to increased concentrations of H2O2 and SOA as well as a shift in the size-distribution toward larger particles (0.3-0.7 microm diameter), potentially increasing the amount of H2O2 delivered to the lower respiratory region. This study increases our understanding of H2O2 exposures, including exposures to H2O2 associated with co-occurring hygroscopic aerosols. It also re-emphasizes the potential of ozone-driven chemistry to alter indoor environments, often producing products more irritating than their precursors.

Aerosols↗

Nitrous acid, nitrogen dioxide, and ozone concentrations in residential environments.

Nitrous acid (HONO) may be generated by heterogeneous reactions of nitrogen dioxide and direct emission from combustion sources. Interactions among nitrogen oxides and ozone are important for outdoor photochemical reactions. However, little is known of indoor HONO levels or the relationship between residential HONO, NO(2), and O(3) concentrations in occupied houses. Six-day integrated indoor and outdoor concentrations of the three pollutants were simultaneously measured in two communities in Southern California using passive samplers. The average indoor HONO concentration was 4.6 ppb, compared to 0.9 ppb for outdoor HONO. Average indoor and outdoor NO(2)concentrations were 28 and 20.1 ppb, respectively. Indoor O(3) concentrations were low (average 14.9 ppb) in comparison to the outdoor levels (average 56.5 ppb). Housing characteristics, including community and presence of a gas range, were significantly associated with indoor NO(2) and HONO concentrations. Indoor HONO levels were closely correlated with indoor NO(2) levels and were about 17% of indoor NO(2) concentrations. Indoor HONO levels were inversely correlated with indoor O(3) levels. The measurements demonstrated the occurrence of substantial residential indoor HONO concentrations and associations among the three indoor air pollutants.

Air Pollution, Indoor↗