Three-dimensional delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at 1.5T and 3.0T.

PURPOSE: To implement and validate a three-dimensional (3D) T1 measurement technique that is suitable for delayed gadolinium (Gd)-enhanced MRI of cartilage (dGEMRIC) and can be easily implemented with clinically available pulse sequences at 1.5T and 3.0T. MATERIALS AND METHODS: A 3D inversion-recovery prepared spoiled gradient-echo (IR-SPGR) imaging pulse sequence with variable TR was used to implement a 3D T1 measurement protocol. The 3D T1 measurements were validated against a gold-standard single-slice 2D IR T1 measurement protocol in both phantoms and in vivo, in both asymptomatic volunteers and volunteers with osteoarthritis (OA). RESULTS: T1 measurements in phantoms showed a statistically significant correlation between the 2D and 3D measurements at 1.5T (R2=0.993, P<0.001) and 3.0T (R2=0.996, P<0.001). In vivo application demonstrated the feasibility of using this 3D IR-SPGR sequence to evaluate the molecular status of articular cartilage throughout the knee joint with 0.63x0.63x3.0 mm spatial resolution within a 20-minute acquisition, even with the measurement parameters set for the higher T1(Gd) of cartilage at 3T (range=400-900 msec mean T1 within a region of interest (ROI) in cartilage, compared to 200-600 msec mean T1 at 1.5T). CONCLUSION: This 3D T1 measurement protocol may prove useful for the evaluation and follow-up of cartilage dGEMRIC indices in clinical studies of OA.

Cartilage, Articular↗

Single acquisition water-fat separation: feasibility study for dynamic imaging.

Water-fat separation can be challenging in the presence of field inhomogeneities. Three-point (3-pt) water-fat separation methods achieve robust performance by measuring and compensating for field inhomogeneities; however, they triple the scan time. The "1+-pt" water-fat separation method proposed in this article for dynamic or repetitive imaging situations combines 3-pt methods' ability to correct for field inhomogeneities with the scan efficiency of a single acquisition method to achieve high temporal and spatial resolutions and robust water-fat separation. Single-echo data are collected with water and fat at a relative phase shift of an odd multiple of pi/2. To correct for undesired phase modulation, phase maps are estimated from a 3-pt calibration scan acquired prior to dynamic imaging. The phase maps are assumed to be slowly varying in time, so they may be used for correcting the phase of the subsequent single-echo signals at the same imaging location. Noise performance was investigated and shown to be equivalent to a single excitation acquisition. The 1+-pt method can also be used in conjunction with parallel imaging. In this situation, the calibration scans required by both methods can be integrated into a shared calibration scan. Promising results were obtained in breast, abdominal, and cardiac imaging applications.

Abdomen↗

Evaluation of real-time single-shot fast spin-echo MRI for visualization of the fetal midline corpus callosum and secondary palate.

OBJECTIVE: The objective of our study was to assess the visibility of the fetal corpus callosum and soft palate on standard single-shot fast spin-echo (SSFSE) imaging versus real-time (RT) SSFSE imaging. SUBJECTS AND METHODS: Part 1 of the study was a prospective analysis using a questionnaire rating the ease of use and utility of RT imaging. Part 2 of the study was a retrospective analysis of 69 fetal MRI studies with RT sagittal midline imaging of the head, face, or both. Standard and RT SSFSE image sets were de-identified, randomized, and shown to three pediatric neuroradiologists who rated on a 5-point scale whether the images were midline and how well they could see and characterize as normal the corpus callosum and secondary palate. The imaging results were correlated with postnatal diagnosis. Statistical methods included the Wilcoxon's signed rank test, McNemar chi-square test, and analysis of variance. RESULTS: Prospectively, the RT SSFSE technique was ranked as excellent in all the categories assessed. Retrospective analysis showed that the midline view obtained with RT SSFSE imaging was helpful in diagnosing the normal and abnormal secondary palate, allowing improved diagnosis of 19 (30.6%) of 62 cases of normal palate and four (57.1%) of seven cases of abnormal palate, when compared with the standard SSFSE technique. RT SSFSE imaging improved the ability to diagnose a normal corpus callosum on the midline view in 13 (27.6%) of 47 fetuses of 20 or more weeks gestational age. CONCLUSION: The RT SSFSE technique can aid in obtaining images in planes that are critical to the evaluation of a moving fetus, particularly when a midline sagittal view of the corpus callosum or palate is required. The use of this technique may lead to improved diagnosis of CNS or orofacial abnormalities in fetuses.

Corpus Callosum↗

Delayed gadolinium-enhanced magnetic resonance imaging of cartilage in knee osteoarthritis: findings at different radiographic stages of disease and relationship to malalignment.

OBJECTIVE: Delayed gadolinium-enhanced magnetic resonance imaging (MRI) of cartilage (dGEMRIC) is used to examine the distribution of glycosaminoglycan in cartilage. This study sought to characterize dGEMRIC in the evaluation of knee osteoarthritis (OA) according to various radiographically determined disease parameters, and to examine the relationship between alignment of the knee joint and the lateral:medial dGEMRIC ratio. METHODS: Thirty-one patients with knee OA underwent MRI with a dGEMRIC protocol at 1.5T. Semiflexed knee radiographs and full-limb radiographs were also obtained for assessment of alignment. RESULTS: Compartments of the knee joint without joint space narrowing had a higher dGEMRIC index than those with any level of narrowing (mean 408 msec versus 365 msec; P = 0.001). In knees with 1 unnarrowed (spared) and 1 narrowed (diseased) compartment, the dGEMRIC index was greater in the spared versus the diseased compartment (mean 395 msec versus 369 msec; P = 0.001). In spared compartments, there was a trend toward a lower dGEMRIC index with increasing Kellgren/Lawrence (K/L) radiographic severity grade; the spared compartments of knees with a K/L grade 2 had a higher dGEMRIC index than those of knees with a K/L grade 4 (mean 425 msec versus 371 msec; P < 0.05). There was a range of dGEMRIC values in the spared compartments within a given K/L grade, demonstrating biochemical differentiation of disease in radiographically comparable compartments. Almost all compartments with narrowing had dGEMRIC indices of <400 msec. Valgus-aligned knees tended to have lower dGEMRIC values laterally, and varus-aligned knees tended to have lower dGEMRIC values medially; as a continuous variable, alignment correlated with the lateral:medial dGEMRIC ratio (Pearson's R = 0.43, P = 0.02). CONCLUSION: The biochemical information provided by dGEMRIC scans may augment radiography by improving the differentiation of disease status within a given radiographic grade, especially in early OA.

Aged↗

Parallel magnetic resonance imaging with adaptive radius in k-space (PARS): constrained image reconstruction using k-space locality in radiofrequency coil encoded data.

A parallel image reconstruction algorithm is presented that exploits the k-space locality in radiofrequency (RF) coil encoded data. In RF coil encoding, information relevant to reconstructing an omitted datum rapidly diminishes as a function of k-space separation between the omitted datum and the acquired signal data. The proposed method, parallel magnetic resonance imaging with adaptive radius in k-space (PARS), harnesses this physical property of RF coil encoding via a sliding-kernel approach. Unlike generalized parallel imaging approaches that might typically involve inverting a prohibitively large matrix for arbitrary sampling trajectories, the PARS sliding-kernel approach creates manageable and distributable independent matrices to be inverted, achieving both computational efficiency and numerical stability. An empirical method designed to measure total error power is described, and the total error power of PARS reconstructions is studied over a range of k-space radii and accelerations, revealing "minimal-error" conditions at comparatively modest k-space radii. PARS reconstructions of undersampled in vivo Cartesian and non-Cartesian data sets are shown and are compared selectively with traditional SENSE reconstructions. Various characteristics of the PARS k-space locality constraint (such as the tradeoff between signal-to-noise ratio and artifact power and the relationship with iterative parallel conjugate gradient approaches or nonparallel gridding approaches) are discussed.

Algorithms↗

Inherently self-calibrating non-Cartesian parallel imaging.

The use of self-calibrating techniques in parallel magnetic resonance imaging eliminates the need for coil sensitivity calibration scans and avoids potential mismatches between calibration scans and subsequent accelerated acquisitions (e.g., as a result of patient motion). Most examples of self-calibrating Cartesian parallel imaging techniques have required the use of modified k-space trajectories that are densely sampled at the center and more sparsely sampled in the periphery. However, spiral and radial trajectories offer inherent self-calibrating characteristics because of their densely sampled center. At no additional cost in acquisition time and with no modification in scanning protocols, in vivo coil sensitivity maps may be extracted from the densely sampled central region of k-space. This work demonstrates the feasibility of self-calibrated spiral and radial parallel imaging using a previously described iterative non-Cartesian sensitivity encoding algorithm.

Algorithms↗

Concentric coil arrays for parallel MRI.

A new type of coil array is proposed that consists of concentrically placed coil elements, each of which is characterized by symmetrically arranged lobes that have alternating current directions. Symmetries in the coil elements' conductor paths allow for the minimization of mutual inductance and noise correlations. In addition, the concentric arrangement of the coil elements provides spatial encoding capabilities in multiple directions, which is valuable when arrays are used with parallel MRI. Simulations are presented that describe the signal-to-noise ratio (SNR) properties of individual concentric array elements, and a four-element prototype concentric array is constructed. This prototype array is compared experimentally with three alternative four-element array designs. The overall SNR of the concentric array is comparable to the SNR of the competing arrays. Reconstruction of twofold undersampled data using the concentric array yields an average g-factor of less than 1.3 in all directions parallel to the plane of the array. There is some degradation in performance when threefold undersampled data are reconstructed, but the array still shows substantial directional invariance compared to alternative designs. Both fully-sampled and undersampled cardiac images acquired using the concentric array are shown. These results suggest that concentric structures can be useful tools for designing specialized coil arrays for parallel MRI.

Computer-Aided Design↗

Rapid volumetric MRI using parallel imaging with order-of-magnitude accelerations and a 32-element RF coil array: feasibility and implications.

RATIONALE AND OBJECTIVES: Many clinical applications of Magnetic Resonance Imaging are constrained by basic limits on imaging speed. Parallel MRI relaxes these limits by using the sensitivity patterns of arrays of radiofrequency receiver coils to encode spatial information in a manner complementary to traditional encoding with magnetic field gradients. Until now, parallel MRI has been used to achieve modest improvements in imaging speed; order-of-magnitude improvements have been elusive given fundamental losses in signal-to-noise ratio. The goal of this work was to demonstrate that, with appropriate hardware and careful SNR management, rapid volumetric imaging at high accelerations is in fact feasible. MATERIALS AND METHODS: Contrast-enhanced MRI with an axial 3D spoiled gradient echo imaging sequence was performed in healthy adult subjects using a 32-element RF coil array and a prototype 32-channel MR imaging system. Large imaging volumes were prescribed, in place of traditional limited slabs targeted only to suspect regions. RESULTS: As much as 16-fold net accelerations of imaging were achieved repeatably using this approach. The use of large 3D volumes allowed comprehensive anatomical coverage at clinically useful spatial and/or temporal resolution. The need for careful, time-consuming, and subject-specific scan prescription was also eliminated. CONCLUSION: The highly parallel imaging approach presented here allows previously inaccessible volumetric coverage for time-sensitive MRI examinations such as contrast-enhanced MRA, and simultaneously provides a substantially simplified imaging paradigm. The resulting capability for rapid volumetric imaging promises to combine the strengths of MRI with some of the advantages of alternative imaging modalities such as multidetector CT.

Adult↗

Phase-constrained parallel MR image reconstruction.

A generalized method for phase-constrained parallel MR image reconstruction is presented that combines and extends the concepts of partial-Fourier reconstruction and parallel imaging. It provides a framework for reconstructing images employing either or both techniques and for comparing image quality achieved by varying k-space sampling schemes. The method can be used as a parallel image reconstruction with a partial-Fourier reconstruction built in. It can also be used with trajectories not readily handled by straightforward combinations of partial-Fourier and SENSE-like parallel reconstructions, including variable-density, and non-Cartesian trajectories. The phase constraint specifies a better-conditioned inverse problem compared to unconstrained parallel MR reconstruction alone. This phase-constrained parallel MRI reconstruction offers a one-step alternative to the standard combination of homodyne and SENSE reconstructions with the added benefit of flexibility of sampling trajectory. The theory of the phase-constrained approach is outlined, and its calibration requirements and limitations are discussed. Simulations, phantom experiments, and in vivo experiments are presented.

Algorithms↗

Effects of inductive coupling on parallel MR image reconstructions.

Theoretical arguments and experimental results are presented that characterize the impact of inductive coupling on the performance of parallel MRI reconstructions. A simple model of MR signal and noise reception suggests that the intrinsic amount of spatial information available from a given coil array is unchanged in the presence of inductive coupling, as long as the sample remains the dominant source of noise for the coupled array. Any loss of distinctness in the measured coil sensitivities is compensated by information stored in the measured noise correlations. Adjustments to the theory are described to account for preamplifier noise contributions. Results are presented from an experimental system in which preamplifier input impedances are systematically adjusted in order to vary the level of coupling between array elements. Parallel image reconstructions using an array with four different levels of coupling and an acceleration factor up to six show average SNR changes of -7.6% to +7.5%. The modest changes in overall SNR are accompanied by similarly small changes in g-factor. These initial results suggest that moderate amounts of inductive coupling should not have a prohibitive effect on the use of a given coil array for parallel MRI.

Image Processing, Computer-Assisted↗

Highly parallel volumetric imaging with a 32-element RF coil array.

The improvement of MRI speed with parallel acquisition is ultimately an SNR-limited process. To offset acquisition- and reconstruction-related SNR losses, practical parallel imaging at high accelerations should include the use of a many-element array with a high intrinsic signal-to-noise ratio (SNR) and spatial-encoding capability, and an advantageous imaging paradigm. We present a 32-element receive-coil array and a volumetric paradigm that address the SNR challenge at high accelerations by maximally exploiting multidimensional acceleration in conjunction with noise averaging. Geometric details beyond an initial design concept for the array were determined with the guidance of simulations. Imaging with the support of 32-channel data acquisition systems produced in vivo results with up to 16-fold acceleration, including images from rapid abdominal and MRA studies.

Equipment Design↗

Shortening MR image acquisition time for volumetric interpolated breath-hold examination with a recently developed parallel imaging reconstruction technique: clinical feasibility.

A recently developed parallel magnetic resonance (MR) imaging technique, parallel imaging with an augmented radius in k space, was used to accelerate the volumetric interpolated breath-hold examination (VIBE) performed in 20 patients referred for clinical liver imaging. Nonaccelerated MR images were also acquired in these patients. A five-point scale was used to score the quality of the images. The acceleration resulted in reduced image quality: The nonaccelerated images had a significantly higher (P <.05) mean score--3.8 +/- 0.3 (SD), indicating good quality--than the accelerated images--3.0 +/- 0.3, indicating acceptable quality. However, for three patients who could not hold their breath for the duration necessary for nonaccelerated imaging, less severe breathing artifacts on the accelerated images resulted in improved quality compared with the quality of the nonaccelerated images. Parallel MR imaging-accelerated VIBE may be beneficial for patients who have difficulty sustaining a breath hold for the duration necessary to perform nonaccelerated imaging.

Adult↗

Self-calibrating parallel imaging with automatic coil sensitivity extraction.

Calibration of the spatial sensitivity functions of coil arrays is a crucial element in parallel magnetic resonance imaging (PMRI). The most common approach has been to measure coil sensitivities directly using one or more low-resolution images acquired before or after accelerated data acquisition. However, since it is difficult to ensure that the patient and coil array will be in exactly the same positions during both calibration scans and accelerated imaging, this approach can introduce sensitivity miscalibration errors into PMRI reconstructions. This work shows that it is possible to extract sensitivity calibration images directly from a fully sampled central region of a variable-density k-space acquisition. These images have all the features of traditional PMRI sensitivity calibrations and therefore may be used for any PMRI reconstruction technique without modification. Because these calibration data are acquired simultaneously with the data to be reconstructed, errors due to sensitivity miscalibration are eliminated. In vivo implementations of self-calibrating parallel imaging using a flexible coil array are demonstrated in abdominal imaging and in real-time cardiac imaging studies.

Abdomen↗

Recent advances in image reconstruction, coil sensitivity calibration, and coil array design for SMASH and generalized parallel MRI.

Parallel magnetic resonance imaging (MRI) techniques use spatial information from arrays of radiofrequency (RF) detector coils to accelerate imaging. A number of parallel MRI techniques have been described in recent years, and numerous clinical applications are currently being explored. The advent of practical parallel imaging presents various challenges for image reconstruction and RF system design. Recent advances in tailored SiMultaneous Acquisition of Spatial Harmonics (SMASH) image reconstructions are summarized. These advances enable robust SMASH imaging in arbitrary image planes with a wide range of coil array geometries. A generalized formalism is described which may be used to understand the relations between SMASH and SENSE, to derive typical implementations of each as special cases, and to form hybrid techniques combining some of the advantages of both. Accurate knowledge of coil sensitivities is crucial for parallel MRI, and errors in calibration represent one of the most common and the most pernicious sources of error in parallel image reconstructions. As one example, motion of the patient and/or the coil array between the sensitivity reference scan and the accelerated acquisition can lead to calibration errors and reconstruction artifacts. Self-calibrating parallel MRI approaches that address this problem by eliminating the need for external sensitivity references are reviewed. The ultimate achievable signal-to-noise ratio (SNR) for parallel MRI studies is closely tied to the geometry and sensitivity patterns of the coil arrays used for spatial encoding. Several parallel imaging array designs that depart from the traditional model of overlapped adjacent loop elements are described.

Calibration↗