Search PubMed⌕ Search

Biomedical subjects

Changjun Liu

Publications and source records attributed to Changjun Liu.

3 recordsLinked to original sources

Phosphate removal from aqueous solutions using raw and activated red mud and fly ash.

The effect of acidification and heat treatment of raw red mud (RM) and fly ash (FA) on the sorption of phosphate was studied in parallel experiments. The result shows that a higher efficiency of phosphate removal was acquired by the activated samples than by the raw ones. The sample prepared by using the RM stirred with 0.25 M HCl for 2h (RM0.25), as well as another sample prepared by heating the RM at 700 degrees C for 2h (RM700), registered the maximum removal of phosphate (99% removal of phosphate). This occurred when they were used in the phosphate sorption studies conducted at pH 7.0 and 25 degrees C with the initial PO(4)(3-) concentration of 155 mg P/l. The FA samples treated in the same way described above can achieve 7.0 and 8.2 mg P/l phosphate removal for FA0.25 and FA700 respectively, corresponding to 45.2% and 52.9% removal. The activated materials performed higher phosphate removal over broader pH range compared with the raw ones. The influences of various factors, such as initial pH and initial phosphate concentration on the sorption capacity were also studied in batch equilibration technique. Solution pH significantly influenced the sorption. Each sample achieved the maximal removal of phosphate at pH 7.0. The amount of phosphate removal increased with the solute concentration. The Freundlich and Langmuir models were used to simulate the sorption equilibrium. The results indicate that the Langmuir model has a better correlation with the experimental data than the Freundlich model.

Adsorption↗

[Study on an optimized patch probe and its biomedical application].

A wide-band patch probe excited by coaxial line, which is useful for noninvasive measurement of superficial tissues at high frequencies, is presented in this paper. Optimization of the probe is performed by genetic algorithm (GA) combined with Finite Difference Time Domain (FDTD). Then the optimized round patch probe is used to measure reflection coefficient for 1-7 GHz. The measured results show some interesting phenomena, which are very useful for reconstruction of electric properties of superficial tissues.

Algorithms↗

A hybrid numerical method to compute erythrocyte TMP in low-frequency electric fields.

This paper presents a coupling method of the finite element method and the boundary element method to compute the transmembrane potential (TMP) of an erythrocyte in a low-frequency electric field. We compute an in vitro erythrocyte's TMP induced by external electric fields by this hybrid method. It takes advantage of the homogeneous characteristics from both intracellular region and extracellular region. Moreover, we may use a fine three-dimensional (3-D) mesh around the thin membrane and avoid 3-D meshes in other regions. Numerical results of a spherical cell show that the hybrid method is accurate. The computed threshold of the applied electric field for membrane electric breakdown agrees well with those experimental results. Numerical results can also guide us to locate the maximum induced TMP on the erythrocyte membrane in various electric fields. Some further applications of the hybrid method are also discussed.

Algorithms↗