Search PubMed⌕ Search

Biomedical subjects

Chaim Lotan

Publications and source records attributed to Chaim Lotan.

23 records · Page 2Linked to original sources

Usefulness of intravascular ultrasound-guided histological measurements after stenting in porcine coronary artery.

BACKGROUND: We evaluated the usefulness of intravascular ultrasound (IVUS) in the non-uniform distribution of in-stent neointimal hyperplasia, comparing macroscopic measurements with IVUS-guided histomorphometry. METHODS: Coronary stenting was performed in 45 left coronaries of 39 pigs, using 18 Tenax (Biotronik Gmbh and Co., Berlin, Germany), 11 bare Genius (Eurocor, Bonn, Germany), 10 polymer-coated Genius (Eurocor) and six Biodivysio Matrix LO (Biodivysio Ltd, Farnham, Surrey, UK) stents. After 4 weeks, coronary angiography and IVUS with automatic pullback were performed. IVUS images were analysed using three-dimensional analysis (EchoPlaque 2; INDEC Systems Inc., Mountain View, California, USA). The stented segments were formalin fixed, embedded in Technovit 9100 and cut to 4-8 microm thick slides. The most diseased in-stent segment was 4.49 +/- 4.54 mm away from the distal stent edge assessed by IVUS. Sections of these segments were stained for histomorphometry. RESULTS: A significant correlation was found between IVUS-guided histomorphometry and three-dimensional IVUS measurements of maximal intimal thickness (r = 0.6985, P < 0.005) and area (r = 0.7736, P < 0.001). Macroscopic measurements resulted in comparable maximal intimal thickness (0.83 +/- 0.43 mm compared with 0.81 +/- 0.46 mm) and area (4.44 +/- 1.73 mm2 compared with 3.45 +/- 1.55 mm2) by IVUS and histomorphometry, respectively. Although stent length, diameter, nominal inflation pressure and time and injury score did not differ between the stents, bare Genius stents resulted in significant smaller neointimal volume compared to Tenax, polymer-coated Genius and Biodivysio stents: 24.46 +/- 4.98 mm3 compared with 59.18 +/- 26.41, 60.46 +/- 10.03 and 61.41 +/- 16.27 mm3, respectively (P < 0.05). CONCLUSION: The significant correlation between IVUS-guided histomorphometry and IVUS measurements confirms the usefulness of IVUS in evaluation of experimental in-stent restenosis. Implantation of bare Genius stents resulted in significant lower neointimal hyperplasia compared to Tenax, polymer-coated Genius or phosphorylcholine-coated Biodivysio stents.

Animals↗

Balloon angioplasty versus bypass grafting in the era of coronary stenting.

BACKGROUND: Patients with multivessel coronary artery disease are candidates for either angioplasty and stenting or coronary artery bypass grafting. A prospective randomized study designed to compare the both methods included only a minority of the eligible patients. OBJECTIVE: To compare coronary artery bypass grafting to angioplasty plus stenting in patients with multivessel disease who declined randomization to a multicenter study (the ARTS). METHODS: During 1997-98 we prospectively followed 96 consecutive patients who were eligible according to the ARTS criteria but refused randomization. Of these patients, 50 underwent angioplasty + stenting and 46 underwent coronary bypass surgery. We compared the incidence of major adverse cardiac and cerebral events, chest pain recurrence, quality of life and procedural cost during the first 6 months. RESULTS: All procedures were completed successfully without mortality or cerebral events. The rate of Q-wave myocardial infarction was 2% in the AS group vs. 0% in the CABG group (not significant). Minor complications occurred in 7 patients (14%) in the AS group and in 21 patients (45%) in the CABG group (P < 0.01). At 6 months follow-up the incidence of major cardiac and cerebral events was similar in both groups (11% and 4% in the AS and CABG groups respectively, P = NS). Seventeen patients (36%) in the AS group required repeat revascularization compared to only 3 (7%) in the CABG group (P = 0.002). Nevertheless, quality of life was better, hospitalization was shorter and the cost was lower during the first 6 months after angioplasty. CONCLUSION: Angioplasty with stenting compared to coronary bypass surgery in patients with multivessel disease resulted in similar short-term major complications. However, 36% of patients undergoing angioplasty may need further revascularization procedures during the first 6 months.

Angioplasty, Balloon, Coronary↗

Percutaneous Transluminal Coronary Angioplasty in Octogenarians.

Revascularization is a theoretically ideal technique for treating repeated angina pectoris in elderly patients. Coronary angioplasty is an attractive option if it can be performed safely. In this report, we describe our experience with 80 angioplastic procedures in 72 patients older than 80 years. Seventy-two of these procedures (90%) were performed after 1990 using the currently available, improved angioplasty equipment. A third of these patients did not have any risk factors for coronary artery disease and 45% had only 1 risk factor. A history of previous myocardial infarction or coronary bypass surgery was present in 48 (67%) patients. In most patients (72%), angioplasty was performed during an admission for unstable angina or acute myocardial infarction. Single-vessel disease was present in 22% of patients. Successful angioplasty was performed in 92% of patients and major complications occurred in 8% of patients. Four patients (6%) died; in all of them, angioplasty was performed emergently to treat cardiogenic shock. None of 68 patients who underwent elective angioplasty for stable angina or a semielective procedure for unstable angina died during the hospitalization. We conclude that angioplasty can be performed safely in the carefully selected octogenarian. There is a low-risk subgroup of patients with limited disease in whom angioplasty is an attractive treatment strategy.

Journal Article↗

Short- and long-term outcomes of the titanium-NO stent registry.

BACKGROUND: Five to 15% of the population have allergy to nickel, chromium, or molybdenum, which is a potential cause for in-stent restenosis. The Titan stent is made of stainless steel and is coated with titanium-nitride oxide (TiNOX), which completely prevents the discharge of metal elements. We performed a real-life multicenter registry to assess the short- and long-term characteristics of the Titan stent. METHODS AND RESULTS: A total of 103 Titan stents was implanted in 100 patients. Patients were 61.4+/-12.6 years old (81 men). Risk factors included hypercholesterolemia (63%), hypertension (53%), diabetes mellitus (DM; 35%), and current smoking (23%). Indications for PCI (percutaneous coronary intervention) were acute coronary syndromes (ACS) in 68% [acute ST elevation myocardial infarction (MI) in 8%], stable AP (angina pectoris) in 25%, and silent ischemia in 7% of the patients. Fifty-two percent of the treated lesions were of Type B2 or C. Lesion length was 14.3+/-2.9 mm and stent diameter was 3.06+/-0.36 mm. Indications for stenting were prevention of restenosis in 66%, residual stenosis in 33%, dissection in 13%, acute MI in 13%, and in-stent restenosis in 7% of the patients. Procedural success was 100%, with no complications. At 30 days, there were no major adverse cardiac events (MACE), including death, MI, and revascularization. At 180 days, only three patients had TVR (target vessel revascularization); two had TLR (target lesion revascularization) (one PCI and one CABG [coronary artery bypass grafting]), and one patient had a new narrowing proximal to the stent and underwent CABG due to multivessel disease. CONCLUSIONS: The Titan stent has a remarkable safety profile in high-risk patients and complex coronary lesions and excellent short- and long-term outcome with a very low clinical TLR rate.

Adult↗

Early mobilization after diagnostic cardiac catheterization with the use of a hemostatic bandage containing thrombin.

The aim of the present study was to assess the efficacy and safety of a thrombin-containing bandage for local hemostasis after femoral sheath removal in patients undergoing diagnostic cardiac catheterization. Forty-one patients undergoing diagnostic coronary angiography using a 6-F femoral sheath were included. The sheath was removed immediately after the procedure using the bandage according to a prespecified protocol. Mean compression time was 7.3+/-1.7 min and mean time from sheath removal to mobilization was 132+/-34 min. None of the patients suffered recurrent bleeding or any in-hospital and 7-day vascular complications. We conclude that in patients undergoing femoral-access diagnostic cardiac catheterization, the use of a hemostatic bandage containing thrombin was associated with short time to hemostasis with the ability for early patient mobilization without vascular complications.

Bandages↗