Search PubMed⌕ Search

Biomedical subjects

Catherine Oppenheim

Publications and source records attributed to Catherine Oppenheim.

13 recordsLinked to original sources

[Brain imaging patterns after stroke].

The advent of new imaging techniques, such as diffusion-weighted sequences, has a great impact on the diagnostic imaging in stroke. The aim of the present paper is to review the brain imaging patterns after stroke, highlight the usefulness of imaging technique for the diagnosis and etiological work-up after stroke. Three causes of ischemic stroke (cerebral venous thrombosis, aortic arch atheroma, patent foramen ovale) are detailed.

Acute Disease↗

Cerebral microembolism during cardiac catheterization and risk of acute brain injury: a prospective diffusion-weighted magnetic resonance imaging study.

BACKGROUND AND PURPOSE: Cerebral microembolism detected by transcranial Doppler occurs systematically during cardiac catheterization, but its clinical relevance remains unknown. Studies suggest that asymptomatic embolic cerebral infarction detectable by diffusion-weighted (DW) MRI might exist after percutaneous cardiac interventions, especially after retrograde catheterization of the aortic valve in patients with valvular aortic stenosis, with a frequency as high as 22% of cases. We investigated the incidence of new ischemic lesions on serial cerebral DW MRI after cardiac catheterization. METHODS: This prospective study involved 46 patients with severe aortic valve stenosis. To assess the occurrence of cerebral infarction, all patients underwent cerebral DW MRI and neurological assessment within 24 hours before and 48 hours after cardiac catheterization and retrograde catheterization of the aortic valve. A subgroup was monitored by transcranial power M-mode Doppler during cardiac catheterization to observe cerebral blood flow and track emboli. RESULTS: One patient had a focal diffusion abnormality on DW MRI before cardiac catheterization. After catheterization, we detected only 1 additional acute cerebral diffusion abnormality in a single case (2.2%), although cerebral microemboli were detected in all transcranial Doppler-monitored patients during cardiac catheterization, as expected. All patients remained asymptomatic. Based on these results a mid-point incidence of 5.9% (95% CI, 0.01 to 12.5) for abnormalities on DW MRI in asymptomatic cardiac catheterization patients in our center can be assigned. CONCLUSIONS: Unsuspected cerebral infarctions can be detected by DW MRI after cardiac catheterization, but this phenomenon remains unfrequent in our series. Further studies are needed to identify factors explaining the discrepancy between these results and those of previous studies.

Aged↗

Diffusion tensor imaging in early Alzheimer's disease.

Our aim was to investigate the extent of white matter tissue damage in patients with early Alzheimer disease (AD) using diffusion tensor magnetic resonance imaging (DTI). Although AD pathology mainly affects cortical grey matter, previous magnetic resonance imaging (MRI) studies showed that changes also exist in the white matter (WM). However, the nature of AD-associated WM damage is still unclear. Conventional and DTI examinations (b=1000 s/mm(2), 25 directions) were obtained from 12 patients with early AD (Mini Mental State Examination [MMSE] score=27, Grober and Buschke test score=33.2, digit span score=5.6) and 12 sex- and age-matched volunteers. The right and left mean diffusivity (MD) and fractional anisotropy (FA) of several WM regions were pooled in each patient and control, and compared between the two groups. Volumes of the whole brain and degree of atrophy of the temporal lobe were compared between the two groups. In AD, MD was increased in the splenium of the corpus callosum and in the WM in the frontal and parietal lobes. FA was bilaterally decreased in the WM of the temporal lobe, the frontal lobe and the splenium compared with corresponding regions in controls. Values in other areas (occipital area, superior temporal area, cingulum, internal capsule, and genu of the corpus callosum) were not different between patients and controls. No correlations were found between the MMSE score and the anisotropy indices. Findings of DTI reveal abnormalities in the frontal and temporal WM in early AD patients. These changes are compatible with early temporal-to-frontal disconnections.

Age Factors↗

Three-dimensional dynamic magnetic resonance angiography for the evaluation of radiosurgically treated cerebral arteriovenous malformations.

We assessed the value of three-dimensional (3D) dynamic magnetic resonance angiography (MRA) for the follow-up of patients with radiosurgically treated cerebral arteriovenous malformations (AVMs). Fifty-four patients with cerebral AVMs treated by radiosurgery (RS) were monitored using conventional catheter angiography (CCA) and 3D dynamic MRA with sensitivity encoding based on the parallel imaging. Cerebral AVM was qualitatively classified by two radiologists into one of five categories in terms of residual nidus size and persistence of early draining vein (I, >6 cm; II, 3-6 cm; III, <3 cm; IV, isolated early draining vein; V, complete obliteration). 3D MRA findings showed a good agreement with CCA in 40 cases (kappa=0.62). Of 23 nidus detected on CCA, 3D dynamic MRA showed 14 residual nidus. Of 28 occluded nidus on 3D dynamic MRA, 22 nidus were occluded on CCA. The sensitivity and specificity of 3D dynamic MRA for the detection of residual AVM were 81% and 100%. 3D dynamic MRA after RS may therefore be useful in association with MRI and can be repeated as long as opacification of the nidus or early venous drainage persists, one CCA remaining indispensable to affirm the complete occlusion at the end of follow-up.

Adult↗

Comparison of five MR sequences for the detection of acute intracranial hemorrhage.

PURPOSE: To evaluate the respective value of 5 MR sequences to distinguish between stroke patients with and without acute intracerebral hemorrhage (ICH). METHODS: MR images obtained < or =6 h after stroke onset of 86 patients (43 ICH, 43 non-ICH) were reviewed by 3 observers who looked for signs of acute ICH on each image set [T(1) and T(2) gradient echo (GRE), FLAIR, T(2)-EPI and DWI], presented separately. RESULTS: For the identification of ICH, intraobserver and interobserver concordance were at least kappa = 0.95 for all sequences. Of all interpretations, 7 (0.4%) were erroneous, with sensitivity and specificity of FLAIR, T(2)-EPI and DWI reaching 100%; GRE sensitivity and specificity were 100% and 95-97.5%, respectively; T(1) sensitivity and specificity were 97.3-100% and 97.4-100%, respectively. All 4 patients misclassified on one pulse sequence were correctly classified on all the other sequences. CONCLUSION: In the setting of acute stroke, each of the 5 studied sequences enables ICH and non-ICH patients to be distinguished with high sensitivity and specificity.

Acute Disease↗

Spontaneous intracerebral hematoma on diffusion-weighted images: influence of T2-shine-through and T2-blackout effects.

BACKGROUND AND PURPOSE: On diffusion-weighted (DW) images, primary hematomas are initially mainly hyperintense, and then hypointense during the first few days after stroke onset. As in other brain disorders, variations in the T2 relaxation time of the hematoma influence the DW imaging signal intensity. Our aim was to evaluate the contribution of the T2 signal intensity and apparent diffusion coefficient (ADC) changes to signal intensity displayed by DW imaging through the course of hematoma. METHODS: The MR images of 33 patients with primary intracranial hemorrhage were retrospectively reviewed. Variations in T2-weighted echo planar images, DW imaging signal intensity, and apparent diffusion coefficient (ADC) ratios (core of hematoma/contralateral hemisphere) were analyzed according to the putative stages of hematoma, as seen on T1- and T2-weighted images. RESULTS: On both T2-weighted echo planar and DW images, the core of the hematomas was hyperintense at the hyperacute (oxyhemoglobin, n = 11) and late subacute stages (extracellular methemoglobin, n = 4), while being hypointense at the acute (deoxyhemoglobin, n = 11) and early subacute stages (extracellular methemoglobin, n = 7). There was a positive correlation between the signal intensity ratio on T2-weighted echo planar and DW images (r = 0.93, P < .05). ADC ratios were significantly decreased in the whole population and in each of the first three stages of hematoma, without any correlation between DW imaging findings and ADC changes (r = 0.09, P = .6). CONCLUSION: Our results confirm that the core of hematomas is hyperintense on DW images with decreased ADC values at the earliest time point, and may thus mimic arterial stroke on DW images. T2 shine-through and T2 blackout effects contribute to the DW imaging findings of hyperintense and hypointense hematomas, respectively, while ADC values are moderately but consistently decreased during the first three stages of hematoma.

Adult↗

Subarachnoid hemorrhage as the initial presentation of dural sinus thrombosis.

Cerebral venous thrombosis (CVT) can be difficult to diagnose because of its wide spectrum of clinical manifestations. Its diagnosis may be further complicated when patients initially present with acute subarachnoid hemorrhage (SAH). We report on four patients with SAH revealing a CVT and discuss the role of imaging for diagnostic and pretherapeutic workup. In three women and one man presenting with severe headaches, images initially suggested SAH with no associated parenchymal bleeding. In all patients, SAH involved the sulci of the convexity and spared the basal cisterns. Digital subtracted angiography showed occlusion of intracranial venous sinuses but did not reveal any other cause of SAH. All patients improved with anticoagulant therapy. Risk factors for CVT and SAH, namely, head trauma and oral contraception, were identified in two patients. These cases highlight the fact SAH may reveal a CVT, which should be considered in the diagnostic workup of SAH, especially when the basal cisterns are not involved.

Adult↗

Diffusion tensor imaging of partial intractable epilepsy.

Our aim was to assess the value of diffusion tensor imaging (DTI) in patients with partial intractable epilepsy. We used DTI (25 non-collinear directions) in 15 patients with a cortical lesion on conventional MRI. Fractional anisotropy (FA) was measured in the internal capsule, and in the normal-appearing white matter (WM), adjacent to the lesion, and away from the lesion, at a set distance of 2-3 cm. In each patient, increased or decreased FA measurements were those that varied from mirror values using an arbitrary 10% threshold. Over the whole population, ipsi- and contralateral FA measurements were also compared using a Wilcoxon test (p<0.05). Over the whole population, FA was significantly reduced in the WM adjacent to and away from the lesion, whilst being normal in the internal capsule. FA was reduced by more than 10% in the WM adjacent to and distant from the lesion in 13 and 12 patients respectively. For nine of the ten patients for whom the surgical resection encompassed the limits of the lesion on conventional MRI, histological data showed WM alterations (gliosis, axonal loss, abnormal cells). DTI often reveals WM abnormalities that are undetected on conventional MRI in patients with partial intractable epilepsy.

Adolescent↗

Evaluation of hyperintense vessels on FLAIR MRI for the diagnosis of multiple intracerebral arterial stenoses.

BACKGROUND AND PURPOSE: Hyperintense vessel sign (HVS) on fluid-attenuated inversion recovery (FLAIR) has been described in hyperacute stroke patients with arterial occlusion. We sought to determine whether HVS was more frequent in patients with intracerebral arterial stenoses than in those without stenosis regardless of the presence of a brain infarct. METHODS: In this case-control study (19 symptomatic patients with multiple intracerebral arterial stenoses compared with 19 age-matched asymptomatic patients without stenosis), we looked for HVS (ie, focal or tubular hyperintensities in the subarachnoid space) on FLAIR images. We compared the proportion of HVS-positive patients in the 2 groups and evaluated the concordance between the arterial distribution of stenoses on angiogram and that of HVS on FLAIR. RESULTS: HVS was found in 13 of 19 patients (68%) in the study group and 1 of 19 control patients (5.2%) (P<0.0001). The concordance between the territorial distribution of stenoses on angiogram and HVS on FLAIR was higher for the right and left middle cerebral artery (kappa=0.6 and 0.63, respectively) compared with the right and left anterior cerebral artery (kappa=0.35 and 0.2, respectively). HVSs were observed in 1 of 7 patients with posterior cerebral artery stenoses on angiogram. HVSs were seen equally in patients with acute focal (7 of 10) or diffuse (6 of 9) cerebral involvement. In the 6 HVS-positive patients with acute stroke confirmed by MRI, additional HVSs were observed in a different arterial territory than that of the stroke lesion. CONCLUSIONS: Although their significance remains unclear, multiple HVSs are more frequently observed in symptomatic patients with multiple intracerebral stenoses than in asymptomatic patients without stenosis.

Adult↗

Which MR-derived perfusion parameters are the best predictors of infarct growth in hyperacute stroke? Comparative study between relative and quantitative measurements.

PURPOSE: To compare predictors of infarct growth in hyperacute stroke from a retrospective review of various relative and quantitative parameters calculated at perfusion-weighted magnetic resonance (MR) imaging performed within 6 hours after ictus. MATERIALS AND METHODS: Fluid-attenuated inversion recovery and diffusion- and perfusion-weighted images were obtained in 66 patients. The initial infarct was delineated on diffusion-weighted images; the hemodynamic disturbance, on apparent mean transit time (MTT) maps; and the final infarct, on follow-up fluid-attenuated inversion recovery images. Relative (without and with deconvolution) and quantitative values of the bolus arrival time, time to peak (TTP), apparent MTT or MTT, cerebral blood volume (CBV), peak height, and cerebral blood flow (CBF) index or CBF were calculated for initial infarct, infarct growth (final minus initial infarct contour), viable hemodynamic disturbance (apparent MTT minus final infarct contour), and contralateral mirror regions. Univariate and multivariate analyses (receiver operating characteristic curves and discriminant analysis) were performed to compare the diagnostic performance of these parameters for predicting infarct growth. RESULTS: At univariate analysis, relative peak height and quantitative CBF were the best predictors of infarct growth; at multivariate analysis, a function of peak height and TTP for relative measurements and CBF alone for quantitative measurements. Quantitative and relative measurements (without or with deconvolution) worked equally well. A combined relative peak height or TTP threshold (<54% or >5.2 seconds, respectively) had a sensitivity of 71% and a specificity of 98%. A quantitative CBF threshold (<35 mL/min/100 g) had a sensitivity of 69% and a specificity of 85%. CONCLUSION: A combination of relative peak height and TTP measurements allowed the best prediction of infarct growth, which obviates more complex quantitative calculation.

Acute Disease↗

Three-dimensional dynamic MR digital subtraction angiography using sensitivity encoding for the evaluation of intracranial arteriovenous malformations: a preliminary study.

BACKGROUND AND PURPOSE: Our aim was to develop 3D dynamic MR digital subtraction angiography with high temporal resolution without sacrificing spatial resolution by using sensitivity encoding for the evaluation of cerebral arteriovenous malformations. METHODS: Nineteen patients with 19 angiographically proven arteriovenous malformations (16 supratentorial and 3 infratentorial) were assessed by conventional catheter angiography and 3D dynamic MR digital subtraction angiography. A 3D contrast-enhanced gradient-echo sequence with sensitivity encoding based on a parallel imaging technique was performed and acquired 20 dynamic images, repeated 18 times every 1.7 seconds. Three-dimensional dynamic MR digital subtraction angiograms were analyzed independently by two radiologists in a blinded fashion with regard to arteriovenous malformation nidus and venous drainage. Conventional catheter angiography was used as reference. RESULTS: All MR imaging examinations were assessable. Interobserver agreement was excellent for the detection of nidus and for the evaluation of nidus size (kappa = 1 and 0.875, respectively) but moderate for the visualization of the venous drainage (kappa = 0.56). All nidi detected on conventional catheter angiography were clearly depicted on 3D dynamic MR digital subtraction angiography. The evaluation of the size of the nidus by both techniques was similar. On 3D dynamic MR angiograms, veins were correctly analyzed in 17 of 19 arteriovenous malformations. CONCLUSION: Our preliminary study demonstrates that 3D dynamic MR digital subtraction angiography using sensitivity encoding with a high spatial resolution is appropriate for the assessment of arteriovenous malformations.

Adult↗