Search PubMed⌕ Search

Biomedical subjects

Catherine Boden

Publications and source records attributed to Catherine Boden.

At least 19 recordsLinked to original sources

Intereye concordance in locations of visual field defects in primary open-angle glaucoma: diagnostic innovations in glaucoma study.

PURPOSE: To determine the overlap in defective visual field locations between the right and left eyes of primary open-angle glaucoma patients. DESIGN: Cross-sectional retrospective analysis of data from a prospectively designed longitudinal study. PARTICIPANTS: Patients with glaucomatous optic neuropathy in at least 1 eye and 2 consecutive reliable standard automated perimetry fields within 15 months were included, yielding 468 eyes of 234 patients. METHODS: Concordance in defective visual field locations between right and left eyes were calculated as the number of overlapping locations divided by the total number of defective locations (intereye concordance ratio). Concordance ratios also were calculated within an eye over time (intraeye concordance ratio) and between unmatched pairs of fields (unmatched concordance ratio). RESULTS: Intereye concordance (0.24+/-0.02) was significantly smaller than intraeye concordance (0.37+/-0.02) and significantly larger than unmatched concordance (0.14+/-0.01). There was a significant interaction between concordance type and defect size, such that there was no difference in concordance ratios for defects of fewer than 8 locations, and the difference between intereye concordance versus intraeye concordance and unmatched concordance ratios increased with larger defect sizes. CONCLUSIONS: A spatial relationship exists between defective locations of an individual's eyes. Future studies will show whether information about the spatial relationship is useful to guide the modification of visual field test locations to improve detection of loss and perhaps also progression.

Adult↗

Relationship between patterns of visual field loss and retinal nerve fiber layer thickness measurements.

PURPOSE: To investigate the association between patterns of visual field (VF) loss and retinal nerve fiber layer (RNFL) thickness measurements. DESIGN: Observational cross-sectional study. METHODS: One hundred twenty-one glaucoma patients and 65 healthy subjects from the Diagnostic Innovations in Glaucoma Study (DIGS) were included. All glaucoma patients had repeatable abnormal VFs and scanning laser polarimetry (SLP) RNFL thickness measurements. RNFL measurements were obtained from 16 equal parapapillary sectors. Patterns of VF loss were classified as arcuate, partial arcuate, nasal step, or paracentral in each VF hemifield. Logistic regression analysis was performed to determine which RNFL sectors were associated with each VF pattern. The ability of SLP to discriminate between eyes with different VF patterns and healthy eyes using receiver operating characteristic (ROC) curve analyses also was investigated. RESULTS: VF patterns in the superior hemifield were significantly associated with RNFL sectors in the temporal inferior hemiretina (P < .05). ROC curve areas for discrimination between eyes with different VF patterns and healthy eyes ranged from 0.85 to 0.95. VF patterns in the inferior hemifield were most strongly associated with temporal superior RNFL sectors (P < .05). ROC curve areas for discrimination between different VF patterns and healthy eyes ranged from 0.73 to 0.98. SLP could discriminate between apparently unaffected VF hemifields in glaucoma eyes and VF hemifields in healthy eyes. CONCLUSIONS: Parapapillary RNFL thickness was topographically related to patterns of VF loss. SLP can differentiate between apparently unaffected VF hemifields in glaucoma eyes and normal VF hemifields in healthy eyes.

Aged↗

Inter-eye comparison of patterns of visual field loss in patients with glaucomatous optic neuropathy.

PURPOSE: To compare inter-eye patterns of visual field (VF) loss on standard automated perimetry (SAP) in patients with glaucomatous optic neuropathy. DESIGN: Observational cross-sectional study. METHODS: Four-hundred-and-ninety eyes of 245 patients with glaucomatous optic neuropathy in at least one eye defined by masked stereophoto review were included. Patients had two reliable SAP visual fields within fifteen months for each eye. Patterns of visual field loss were classified independently by two graders masked to all other patient information. Patterns were described as altitudinal, arcuate, partial arcuate, paracentral, nasal step, temporal wedge, or normal based on the classification system of Keltner and associates. Superior and inferior hemifields were graded separately. RESULTS: Inter-grader agreement in visual field patterns before adjudication was 97% and 94% for the worse eye (superior and inferior hemifield) and 97% and 95% for the better eye (superior and inferior hemifield). The percentage of correspondence by hemifield location was: 53% (superior-superior), 62% (inferior-inferior), 45% (superior-inferior), and 55% (inferior-superior). The highest correspondence of individual glaucomatous VF pattern between eyes was for arcuate (superior-superior) and inferior partial arcuate (inferior-inferior) defects (24% and 26%, respectively). Smaller hemifield patterns showed lower correspondence between the eyes (nasal step, paracentral, temporal wedge, 0% to 13% correspondence). CONCLUSIONS: Patterns of visual field loss between eyes often corresponded within the same VF hemifield (superior-superior, inferior-inferior) as well as between opposite hemifields (inferior-superior), although opposite hemifield correspondence was less common. More advanced visual field defects (for example, partial arcuate) showed higher correspondence rates between the eyes than less advanced defects.

Aged↗

Agreement and repeatability for standard automated perimetry and confocal scanning laser ophthalmoscopy in the diagnostic innovations in glaucoma study.

PURPOSE: To assess agreement between structural and functional testing in classifying eyes as normal or abnormal and their repeatability on two consecutive visits by means of standard automated perimetry (SAP) and confocal scanning laser ophthalmoscopy. DESIGN: Analysis of selected data obtained from a prospective longitudinal observational cohort study, the Diagnostic Innovations in Glaucoma Study. METHODS: One hundred fifty-one participants with a SAP and a Heidelberg Retina Tomograph (HRT) test within a three-month window at two visits within 15 months were included. Eyes were classified by SAP and HRT at each visit. Agreement and repeatability were assessed by kappa statistics. RESULTS: At visit 1, 33 (22%) of 151 eyes had only SAP defects, 11 (7%) eyes had only HRT defects, and 35 (23%) eyes had both SAP and HRT defects. Seventy-two eyes (48%) were classified as normal by both tests. Similar results were obtained for visit 2. The agreement between SAP and HRT in classifying eyes was 70% (kappa = 0.393) at visit one and 68% (kappa = 0.363) at visit 2. Repeatability of classification by SAP alone, HRT alone, and both SAP and HRT between visits 1 and 2 was 84% (kappa = 0.693), 89% (kappa = 0.752), and 90% (kappa = 0.723), respectively. CONCLUSIONS: Agreement between SAP and HRT was only fair at both visits. Repeatability across visits was substantial for SAP alone, HRT alone, and for the combination of SAP and HRT. These results suggest that detection of particular features of glaucomatous damage depends on the technique used. Structural and functional tests appear complementary, and both should be used for early detection of glaucoma.

Female↗

Accuracy of an electronic monitoring and reminder device for use with travoprost eye drops.

PURPOSE: To evaluate the accuracy of a prototype electronic device for recording eye drop usage. PARTICIPANTS AND METHODS: Ten volunteers were randomly assigned to one of five usage patterns designed to mimic common patterns of use in glaucoma patients from 100% compliant to 50% compliant. All participants agreed to adhere to a pre-determined "dosing" schedule for 15 days using the monitoring/reminder device to instill artificial tears. Participants also recorded drop usage in a diary. The main outcome measures were device accuracy and reproducibility. Device accuracy was defined as the magnitude of the difference between the diary and device output for three variables: date, number of drops, and instillation time. RESULTS: Date stamping by the device was 100% accurate. The mean +/- SD time difference between the device and the diary was -2.0 +/- 19.7 minutes when data from all participants was pooled. In seven of the ten participants, the device did not record at least one drop. The mean +/- SD difference in the number of drops recorded by the device minus the diary was 0.16 +/- 0.97 when data from all participants was pooled. CONCLUSIONS: The prototype compliance reminder/monitoring device may underestimate compliance in some patients. The date and time stamping mechanisms were generally accurate and reproducible.

Antihypertensive Agents↗

The effects of optical blur on motion and texture perception.

PURPOSE: The purpose of this study is to determine how decreased visual acuity affects performance on tasks of motion and texture perception. METHODS: Positive diopter lenses were used to match three subjects at five levels of decimal visual acuity (DVA) ranging from an uncorrected DVA of 1.6 to the lowest DVA of 0.2. Performance thresholds were determined at each acuity level for five different psychophysical tasks. The tasks assessed the perception of motion-defined form, global motion, maximum motion displacement (Dmax), texture-defined form, and global texture. RESULTS: Reducing visual acuity decreased performance on the tasks of motion-defined form identification, texture-defined form identification, and global texture integration. Performance on the Dmax task improved with a reduction in visual acuity. Performance on the global motion task was unaffected by changes in visual acuity. CONCLUSIONS: Visual acuity should be considered when interpreting the results of developmental or clinical studies of motion and texture perception. The only exception to this is global motion perception, at least when DVA is better than 0.2. The effect of blur on tasks of motion and texture perception may reflect the extent to which high spatial frequency information is required for performance on these tasks.

Humans↗

Identifying glaucomatous vision loss with visual-function-specific perimetry in the diagnostic innovations in glaucoma study.

PURPOSE: To compare the diagnostic results of four perimetric tests and to identify useful parameters from each for determining abnormality. METHODS: One hundred eleven eyes with glaucomatous optic neuropathy (GON), 31 with progressive optic neuropathy (PGON) 53 with ocular hypertension, and 51 with no disease were included (N = 246). Visual field results were not used to classify the eyes. Short-wavelength automated perimetry (SWAP), frequency-doubling technology perimetry (FDT), high-pass resolution perimetry (HPRP), and standard automated perimetry (SAP) were performed. Receiver operating characteristic (ROC) curves were used to compute the areas under the curves (AUC) and sensitivity levels at given specificities for a variety of abnormality criteria. The agreement among tests for abnormality, location, and extent of visual field deficit were assessed. RESULTS: AUC analysis: When the normal group was compared with the GON group, the FDT pattern SD (PSD) area was larger than the HPRP PSD (P = 0.020), and the FDT area of total deviation (TD) <5% was larger than the HPRP mean deviation (MD; P = 0.004). When the normal group was compared with the PGON group, the FDT area of pattern deviation (PD) <5% was larger than the SWAP PSD (P = 0.020). A difference from previous work was that AUCs for PSD or the best SAP were not significantly poorer than those in the function-specific tests. At set specificities, FDT yielded higher sensitivities than all other tests for all parameters. The agreement among tests for abnormality was fair to moderate (kappa = 247-0.563). When loss was present on more than one test, the quadrant of the visual field affected was the same in 95% (79/83) of eyes. The number of eyes identified and number of abnormal quadrants increased across groups with increasing certainty of glaucoma. CONCLUSIONS: At equal specificity, no single perimetric test was always affected, whereas others remained normal. Several parameters at suggested criterion values provided good sensitivity and specificity. FDT showed the highest sensitivity overall, with SAP performing better than in prior reports. Of note, the same area of the retina was identified as damaged in all tests.

Adult↗

Agreement among 3 optical imaging methods for the assessment of optic disc topography.

PURPOSE: To assess the agreement of disc topography measurements between the Heidelberg Retina Tomograph (HRT II), Retinal Thickness Analyzer (RTA), and Optical Coherence Tomograph (StratusOCT). DESIGN: Observational cross-sectional study. PARTICIPANTS: Forty-two randomly chosen eyes of 42 subjects. METHODS: Each subject underwent HRT II, RTA, and StratusOCT examination. Two experienced examiners drew the contour lines for the HRT II and RTA. Bland and Altman plots were used to evaluate agreement for each topographic parameter among the instruments. The Spearman coefficient of rank correlation was evaluated for each topographic parameter. MAIN OUTCOME MEASURES: Agreement in the measurement of optic disc topography among 3 imaging instruments, as evaluated by regression-based 95% limits of agreement. RESULTS: For optic disc area, the agreement between HRT II-RTA and StratusOCT-RTA revealed the existence of proportional bias, indicated by significant slopes of the regression lines (P = 0.01 and P = 0.02, respectively). The 95% limits of agreement between instruments varied with the actual optic disc size measurement. Heidelberg Retina Tomograph disc area measurements tended to be consistently lower than StratusOCT disc area measurements (fixed bias). The Spearman correlation coefficient between the instruments ranged from r = 0.35 (rim area, HRT II-StratusOCT) to r = 0.91 (cup area, HRT II-RTA). CONCLUSIONS: Moderate to high correlation was found in measurements of optic disc topography among different instruments. However, the analysis of agreement indicated important discrepancies among instruments. Therefore, these instruments should not be used interchangeably to obtain measurements of the optic disc for glaucoma diagnosis.

Aged↗

Differences in visual function and optic nerve structure between healthy eyes of blacks and whites.

OBJECTIVE: To investigate differences in visual function, optic disc topography, and retinal nerve fiber layer (RNFL) thickness between healthy eyes of blacks and whites. METHODS: Visual function was assessed in healthy eyes of 50 blacks and 50 whites using standard automated perimetry, short-wavelength automated perimetry, and frequency doubling technology perimetry. Optic disc topography and RNFL thickness were measured using the Heidelberg Retina Tomograph and the optical coherence tomograph. RESULTS: Mean standard automated perimetry mean deviations were within the normal range for both groups. Blacks had worse mean deviation values than whites using frequency doubling technology perimetry (mean +/- SD, -1.8 +/- 3.2 dB vs -0.1 +/- 2.4 dB), blacks had larger optic disc areas than whites using the Heidelberg Retina Tomograph (mean +/- SD, 2.1 +/- 0.4 mm2 vs 1.7 +/- 0.4 mm2), the RNFL of blacks was thicker than that of whites by 16.91 microm superiorly and 10.10 microm inferiorly using optical coherence tomography, and blacks had slightly higher intraocular pressures than whites (mean +/- SD, 16.5 +/- 2.5 mm Hg vs 15.2 +/- 3.2 mm Hg) and thinner central corneas (mean +/- SD, 540.5 +/- 43.2 microm vs 560.9 +/- 35.5 microm). No racial differences were found in mean RNFL thickness, pattern standard deviation on all tests, or any of the short-wavelength automated perimetry variables. CONCLUSIONS: Minimal racial differences in visual function were found, but race significantly affected optic disc topography and superior and inferior RNFL thickness measurements in healthy eyes. The racial differences observed for intraocular pressure could theoretically increase after correcting for central corneal thickness. Prospective studies are needed to further investigate these findings.

Anthropometry↗

Deficient motion perception in the fellow eye of amblyopic children.

The extent of motion processing deficits and M/dorsal pathway involvement in amblyopia is unclear. Fellow eye performance was assessed in amblyopic children for motion-defined (MD) form, global motion, and maximum displacement (Dmax) tasks. Group performance on MD form was significantly worse in amblyopic children than in control children. Global motion deficits were significantly related to residual binocular function. Abnormally elevated Dmax thresholds were most prevalent in children with anisometropia. Our findings from these three uncorrelated tasks implicate involvement of binocular motion-sensitive mechanisms in the neural deficits of amblyopic children with strabismic, anisometropic, and aniso-strabismic etiologies.

Amblyopia↗

Relationship of SITA and full-threshold standard perimetry to frequency-doubling technology perimetry in glaucoma.

PURPOSE: To compare full-threshold (FT) and SITA algorithms for standard automated perimetry (SAP) with frequency-doubling technology perimetry (FDT) in glaucoma, to help clinicians to relate results in patients who have had two or more of these tests during follow-up. METHODS: This study was a retrospective analysis of data from a longitudinal prospective study at the University of California, San Diego. One hundred four eyes of 104 patients with glaucomatous optic neuropathy detected by optic disc stereophotographs were included. All patients had standard perimetry (SITA and FT) and FDT within 3 months of each other. Global indices, abnormality and severity using two threshold algorithms of standard perimetry were compared with FDT. RESULTS: More eyes had normal visual fields by SAP-FT (57 eyes) than by either SAP-SITA (42 eyes) or FDT (45 eyes), although SAP-FT agreed more closely with FDT (kappa = 0.54 +/- 0.08) on the presence of a visual field defect than did SAP-SITA (kappa = 0.34 +/- 0.08). Correlations of FDT to standard perimetry global indices were similar regardless of the threshold strategy used for standard perimetry, yielding r2= 0.38-0.57 for SAP-FT with FDT, 0.36-0.54 for SAP-SITA with FDT. CONCLUSIONS: Despite many similarities of SAP-SITA and SAP-FT, switching the standard of comparison from SAP-FT to SAP-SITA changes the relationship to FDT with regard to visual field abnormality, but not correlations of global indices. FDT detected abnormal fields in more eyes than SAP-FT. SAP-FT tended to detect a subset of eyes found abnormal by FDT. Visual field defects may be detected more often by FDT and SAP-SITA in eyes with early visual field loss, but these two tests may not agree on which eyes show field loss in patients who undergo both tests at follow-up.

Algorithms↗

Using unsupervised learning with independent component analysis to identify patterns of glaucomatous visual field defects.

PURPOSE: Clustering by unsupervised learning with machine learning classifiers was shown to segment clusters of patterns in standard automated perimetry (SAP) for glaucoma in previous publications. In this study, unsupervised learning by independent component analysis decomposed SAP field patterns into axes, and the information represented by these axes was evaluated. METHODS: SAP fields were used that were obtained with the Humphrey Visual Field Analyzer (Carl Zeiss Meditec, Dublin, CA) from 189 normal eyes and 156 eyes with glaucomatous optic neuropathy (GON) determined by masked review with stereoscopic optic disc photographs. The variational Bayesian independent component analysis mixture model (vB-ICA-mm) partitioned the SAP fields into the most informative number of clusters. Simultaneously, the model learned an optimal number of maximally independent axes for each cluster. RESULTS: The most informative number of clusters in the SAP set was two. vB-ICA-mm placed 68.6% of the eyes with GON in a cluster labeled G and 98.4% of the eyes with normal optic discs in a cluster labeled N. Cluster G optimally contained six axes. Post hoc analysis of patterns generated at -1 SD and +2 SD from the cluster G mean on the six axes revealed defects similar to those identified by experts as indicative of glaucoma. SAP fields associated with an axis showed increasing severity, as they were located farther in the positive direction from the cluster G mean. CONCLUSIONS: vB-ICA-mm represented the SAP fields with patterns that were meaningful for glaucoma experts. This process also captured severity in the patterns uncovered. These findings should validate vB-ICA-mm as a data-mining technique for new and unfamiliar complex tests.

Artificial Intelligence↗

Unsupervised machine learning with independent component analysis to identify areas of progression in glaucomatous visual fields.

PURPOSE: To determine whether a variational Bayesian independent component analysis mixture model (vB-ICA-mm), a form of unsupervised machine learning, can be used to identify and quantify areas of progression in standard automated perimetry fields. METHODS: In an earlier study, it was shown that a model using vB-ICA-mm can separate normal fields from fields with six different patterns of visual field loss related to glaucomatous optic neuropathy (GON) along maximally independent axes. In the present study, an independent group of 191 patient eyes (66 with ocular hypertension (OHT), 12 with suspected glaucoma by field, 61 with suspected glaucoma by disc, and 52 with glaucoma) with five or more standard visual fields under observation for a mean of 6.24 +/- 2.65 years and 8.11 +/- 2.42 visual fields were evaluated with the vB-ICA-mm. In addition, eyes with progressive GON (PGON) were identified (n = 39). Each participant had a series of fields tested, with each field entered independently and placed along the axes of the previously developed model. This allowed change in one pattern of visual field defect (along one axis) to be assessed relative to results other areas of that same field (no change along other axes). Progression was based on a slope falling outside the 5th and the 95th percentile limits of all slopes, with at least two axes not showing such a deviation in a given individual's series of fields. Fields were also scored using Advanced Glaucoma Intervention Study (AGIS) and the Early Manifest Glaucoma Treatment Trial (EMGT) criteria. RESULTS: Thirty-two of 191 eyes progressed on vB-ICA-mm by this definition. Of the 32, 22 had field loss at baseline, 7 had only GON, 3 were OHTs and 12 were from the 39 eyes (31%) with PGON. The vB-ICA-mm identified a higher percentage of progressing eyes in each diagnostic category than did AGIS or and the EMGT. CONCLUSIONS: The vB-ICA-mm can quantitatively identify progression in eyes with glaucoma by evaluating change in one or more patterns of the visual field loss while other areas or patterns remain stable. This may enable each eye to contribute to the determination of whether change is caused by true progression or by variability.

Adult↗

Patterns of glaucomatous visual field progression identified by three progression criteria.

PURPOSE: To determine typical patterns of repeatable glaucomatous visual field progression. DESIGN: Retrospective analysis of data obtained from two prospective studies. METHODS: Included were 72 eyes of 72 patients tested up to six times over 2 years, and 40 eyes of 40 patients followed annually for up to 12 years. Each patient had two abnormal baseline visual fields, abnormal optic nerves, and serial fields. Progression was identified using three methods: by glaucoma change probability using total deviation (GCP-TD) and pattern deviation (GCP-PD) plots and by a clinical criteria. Progression was categorized as deepening or expansion of an existing scotoma, or a new scotoma. RESULTS: The percentage of eyes repeatably progressed ranged from 17% to 27%. The most common pattern of progression was a deepening of an existing scotoma in the annual group, followed by expansion. With two follow-ups required, percentages for deepening only were 20% (clinical classifier). A combination of expansion and deepening was most common for the GCP criteria: 15% (GCP-TD classifier), and 10% (GCP-PD classifier) for the annual group. For the semiannual group, deepening was most common with the clinical criteria (11% of eyes), and deepening with expansion was most common by GCP criteria (14%, GCP-TD and GCP-PD). No eyes showed repeatable new scotomas. CONCLUSIONS: Glaucomatous visual fields progress in the area of the visual field where baseline testing showed an existing scotoma. Follow-up testing might be improved by concentrating on already defective locations and using sparser test patterns or screening algorithms in normal areas of the visual field.

Diagnostic Techniques, Ophthalmological↗

Children with dyslexia: evidence for visual attention deficits in perception of rapid sequences of objects.

The attentional blink (AB) refers to a decrease in accuracy that occurs when observers are required to identify, detect or classify the second of two rapidly-sequential targets. The AB is typically attributed to an inability to rapidly reallocate attentional resources from the first to the second target. Thus, it provides an ideal tool to investigate how visual attention is rapidly allocated to sequences of stimuli such as occurs when reading. In the present work, we compared the magnitude of the AB in children with developmental dyslexia to reading-matched and age-matched control groups. In Experiment 1, when two targets were presented in the same spatial location, the AB deficit was similar in the reading-matched and dyslexic groups, but greater in the dyslexic group than in age-matched controls. In Experiment 2, when targets were presented in different spatial locations, performance in the dyslexic group was worse than the age-matched controls and marginally worse than the reading-matched controls. Taken together, the results argue for developmental delays in the ability of children with dyslexia to allocate attention to rapidly-sequential stimuli, as well as some evidence for difficulties that are unique to this group.

Adolescent↗

Using unsupervised learning with variational bayesian mixture of factor analysis to identify patterns of glaucomatous visual field defects.

PURPOSE: To determine whether an unsupervised machine learning classifier can identify patterns of visual field loss in standard visual fields consistent with typical patterns learned by decades of human experience. METHODS: Standard perimetry thresholds for 52 locations plus age from one eye of each of 156 patients with glaucomatous optic neuropathy (GON) and 189 eyes of healthy subjects were clustered with an unsupervised machine classifier, variational Bayesian mixture of factor analysis (vbMFA). RESULTS: The vbMFA formed five distinct clusters. Cluster 5 held 186 of 189 fields from normal eyes plus 46 from eyes with GON. These fields were then judged within normal limits by several traditional methods. Each of the other four clusters could be described by the pattern of loss found within it. Cluster 1 (71 GON + 3 normal optic discs) included early, localized defects. A purely diffuse component was rare. Cluster 2 (26 GON) exhibited primarily deep superior hemifield defects, and cluster 3 (10 GON) held deep inferior hemifield defects only or in combination with lesser superior field defects. Cluster 4 (6 GON) showed deep defects in both hemifields. In other words, visual fields within a given cluster had similar patterns of loss that differed from the predominant pattern found in other clusters. The classifier separated the data based solely on the patterns of loss within the fields, without being guided by the diagnosis, placing 98.4% of the healthy eyes within the same cluster and spreading 70.5% of the eyes with GON across the other four clusters, in good agreement with a glaucoma expert and pattern standard deviation. CONCLUSIONS: Without training-based diagnosis (unsupervised learning), the vbMFA identified four important patterns of field loss in eyes with GON in a manner consistent with years of clinical experience.

Algorithms↗

Retinal nerve fiber layer thickness measured with optical coherence tomography is related to visual function in glaucomatous eyes.

PURPOSE: To determine the relationship between areas of glaucomatous retinal nerve fiber layer thinning identified by optical coherence tomography and areas of decreased visual field sensitivity identified by standard automated perimetry in glaucomatous eyes. DESIGN: Retrospective observational case series. PARTICIPANTS: Forty-three patients with glaucomatous optic neuropathy identified by optic disc stereo photographs and standard automated perimetry mean deviations >-8 dB were included. METHODS: Participants were imaged with optical coherence tomography within 6 months of reliable standard automated perimetry testing. MAIN OUTCOME MEASURES: The location and number of optical coherence tomography clock hour retinal nerve fiber layer thickness measures outside normal limits were compared with the location and number of standard automated perimetry visual field zones outside normal limits. Further, the relationship between the deviation from normal optical coherence tomography-measured retinal nerve fiber layer thickness at each clock hour and the average pattern deviation in each visual field zone was examined by using linear regression (R(2)). RESULTS: The retinal nerve fiber layer areas most frequently outside normal limits were the inferior and inferior temporal regions. The least sensitive visual field zones were in the superior hemifield. Linear regression results (R(2)) showed that deviation from the normal retinal nerve fiber layer thickness at optical coherence tomography clock hour positions 6 o'clock, 7 o'clock, and 8 o'clock (inferior and inferior temporal) was best correlated with standard automated perimetry pattern deviation in visual field zones corresponding to the superior arcuate and nasal step regions (R(2) range, 0.34-0.57). These associations were much stronger than those between clock hour position 6 o'clock and the visual field zone corresponding to the inferior nasal step region (R(2) = 0.01). CONCLUSIONS: Localized retinal nerve fiber layer thinning, measured by optical coherence tomography, is topographically related to decreased localized standard automated perimetry sensitivity in glaucoma patients.

Adult↗

The structure-function relationship in eyes with glaucomatous visual field loss that crosses the horizontal meridian.

OBJECTIVE: To evaluate the relationship between visual field loss and glaucomatous optic discs in eyes in which field loss spreads across the horizontal meridian. SUBJECTS AND METHODS: Ninety-six patients with glaucoma (9 advanced, 60 moderate, and 27 early) with 2 successive abnormal fields were included. Standard achromatic automated perimetry defects were identified with a nerve fiber bundle map to identify abnormal sectors. Crossover was present if the superior and inferior sectors at the horizontal meridian (nasal, central, or temporal) were both abnormal. Optic disc damage was assessed by masked grading of simultaneous stereophotographs. RESULTS: Only 30% (29) of glaucomatous eyes showed crossover, and only 2 of those eyes had early loss. The most frequent pattern of visual field loss (41% of eyes) was single hemifield damage with defects in contiguous sectors. Regardless of the pattern or severity of visual loss, most eyes (66 [69%] of 96) had both superior and inferior optic disc damage. CONCLUSIONS: Early glaucomatous visual field loss rarely crosses the horizontal meridian, but defects in both hemifields at the horizontal meridian are more common in more advanced field loss. In 26 (90%) of 29 eyes with crossover, it could be explained by changes at the optic nerve head.

Adult↗