Search PubMed⌕ Search

Biomedical subjects

Catherine Amrein

Publications and source records attributed to Catherine Amrein.

4 recordsLinked to original sources

Human leukocyte antigen sensitization in ventricular assist device recipients: a lesser risk with the DeBakey axial pump.

BACKGROUND: Previous reports, all concerning pulsatile devices, have indicated an increased risk of development of circulating antileukocyte antigen (HLA; human leukocyte antigen) antibodies during ventricular assist device (VAD) support. We investigated sensitization in patients implanted with the DeBakey VAD (MicroMed Technology, Inc, Houston, TX) axial flow pump as a bridge to heart transplantation. METHODS: Inclusion criteria for this prospective study were the following. Patients implanted with the DeBakey VAD axial flow pump, without HLA antibodies prior to implantation, with a duration of support of at least one month. The HLA antibody testing for IgG and IgM class I and II antibodies was performed weekly during support, using both a complement dependant cytotoxicity assay and an enzyme-linked immunosorbent assay (ELISA). Retrospective cross match was performed for all patients transplanted. The occurrence of graft rejection was determined by regular endomyocardial biopsies after heart transplantation, graded according to the International Society for Heart and Lung Transplantation (ISHLT) guidelines. Additionally, the transfusion history was reviewed for all patients. RESULTS: Fourteen patients were included representing 1,220 cumulative patient-days of support (mean duration time on support, 87 days). No patient developed detectable IgG antibodies to class I or II. One patient had a positive ELISA, corresponding to nonsignificant (6/30) class I IgM antibodies at 3 weeks postimplantation. Ten patients underwent successful heart transplantation, representing 156 cumulative months. No retrospective cross match was positive. The percentage of significant acute rejection episodes (ISHLT grade 3A or more) was 6% and 4.3% in the first 6 months and from 6 to 12 months, respectively. No vascular rejection was noted. The posttransplantation survival rate was 87% at 6 months and 75% at 1 year, respectively. CONCLUSIONS: Patients implanted with the DeBakey VAD axial flow pump as a bridge to heart transplantation do not appear to be exposed to an increased risk of sensitization.

Adult↗

Acute vascular humoral rejection in a sensitized cardiac graft recipient: diagnostic value of C4d immunofluorescence.

A 37-year-old female patient had a cardiac transplantation for dilated cardiomyopathy. She was sensitized by two pregnancies showing anti-human leukocyte antigen I and II antibodies. The pretransplantation crossmatch was negative, but she developed acute humoral rejection characterized by vascular C4d deposits, arteriolitis, and intravascular leukocyte accumulation and adhesion in venules. Although C4d deposits disappeared in 4 weeks, she had persistent endothelial cell activation (endothelial expression of ELAM-1, VCAM-1, or human leukocyte antigen class II) throughout the 6 months of follow-up. Although she received intensive immunosuppression, she presented three episodes of acute cellular rejection during that period of time. This case shows that C4d deposits represent a sensitive marker of acute humoral rejection in cardiac transplantation. Therefore, C4d immunofluorescence should be more frequently assessed in endomyocardial biopsies.

Acute Disease↗

Human leukocyte antigen-G expression after heart transplantation is associated with a reduced incidence of rejection.

BACKGROUND: Human leukocyte antigen (HLA)-G, a nonclassic major histocompatibility complex class I molecule expressed in the extravillous cytotrophoblast at the feto-maternal interface, is known to protect the fetus from maternal cellular immunity. In a preliminary study, we showed that HLA-G is expressed in the hearts of some patients after heart transplantation. METHODS AND RESULTS: In the present study, a larger number of patients was investigated to confirm this finding and to look for possible correlations between HLA-G expression and the number and types of rejection. Expression of HLA-G in endomyocardial biopsy specimens was investigated by immunohistochemical analysis, and detection of the soluble HLA-G in the serum was performed by immunoprecipitation followed by Western blot analysis. HLA-G was detected in the biopsy specimens and serum of 9 of 51 patients (18%). The number of episodes of acute rejection was significantly lower in HLA-G-positive patients (1.2+/-1.1) as compared with HLA-G-negative patients (4.5+/-2.8) (P<0.001). No chronic rejection was observed in HLA-G-positive patients, whereas 15 HLA-G-negative patients had chronic rejection (P<0.032). A longitudinal study of these patients reveals that the status of HLA-G expression was maintained after 6 months both in serum and in biopsy specimens. During this period, HLA-G-positive patients did not have chronic rejection. CONCLUSIONS: There is a significant correlation between rejection and HLA-G expression in the heart after transplantation. HLA-G expression and its effect in reducing the incidence and severity of rejection seem to be stable throughout the evolution.

Adult↗