Search PubMed⌕ Search

Biomedical subjects

Carlos Domínguez

Publications and source records attributed to Carlos Domínguez.

2 recordsLinked to original sources

The use of neural networks for predicting the result of endoscopic treatment for vesico-ureteric reflux.

OBJECTIVE: To create an artificial neural network (ANN) to aid in predicting the results of endoscopic treatment for vesico-ureteric reflux (VUR). MATERIALS AND METHODS: During 1999-2001 we used endoscopic treatment in 261 ureteric units with VUR of all grades and causes. An ANN based on multilayer perceptron architecture was created using an 11 x 6 x 1 structure, taking the following as variables: the cause and grade of VUR, the patient's age and sex, the type of implanted substance and its volume, the number of treatments, the affected ureter, the endoscopic findings, and the type of cystography used. In all, 174 cases were used as training samples for the ANN and 87 to validate it. We calculated the sensitivity, specificity, positive (PPV) and negative predictive values (NPV), and the success rate (%) of the system. RESULTS: In the training group the ANN gave a sensitivity of 86.4%, a specificity of 89.5%, a PPV of 76% and NPV of 94%, with a success rate of 88.6%. In the same training group logistic regression (LR) gave respective values of 68.2%, 58.8%, 39%, 82.7% and 61.4%. In the validation group the respective values for the ANN were 71.4%, 81.6%, 58.8%, 88.6% and 78.9%, and in the same validation group the LR gave 64.4%, 50%, 32.1%, 79.2% and 53.9%. The Wilcoxon test confirmed the independence of both methods (P < 0.001). CONCLUSION: The ANN is an effective tool for assisting the urologist in indicating and applying endoscopic treatments for VUR.

Adolescent↗

Improved integrated waveguide absorbance optodes for ion-selective sensing.

The first prototype of a technologically improved integrated waveguide absorbance optode (IWAO) was developed and tested with a membrane based on a new H+-selective ketocyanine dye and a cadmium ionophore. It was designed with curved instead of rectilinear planar waveguides. Results demonstrated the suitability of the new IWAOs to be employed as sensing platforms, which confer versatility, robustness, and mass production capabilities besides high sensitivity on conventional bulk optodes, as well as the usefulness of such dyes in developing ion-selective membranes in combination with a selective ionophore. The sensor integration as a detector in a flow injection system (FIA) was proposed to obtain an automated, simple, and sufficiently reproducible (RSD <5%) analytical methodology with a sample throughput of 55 h(-1). Very sensitive optodes were obtained, and detection limits on the order of 20 ppb were achieved. Because of the ionophore employed, the optode system showed excellent selectivity over alkali and alkaline-earth metals with the exception of samples containing lead and cadmium ions, where the membrane responded to both analytes. The proposed procedure combines all the advantages of the FIA systems, the simplicity of optical detection, ion recognition selectivity, and sensitivity of ketocyanine dyes, and the features achieved using the integrated device, which comprise an improved sensitivity and short response times as well as robustness, easy handling, and mass production.

Journal Article↗