Search PubMed⌕ Search

Biomedical subjects

Can Ince

Publications and source records attributed to Can Ince.

38 records · Page 3Linked to original sources

Excitation pulse deconvolution in luminescence lifetime analysis for oxygen measurements in vivo.

Oxygen-dependent quenching of phosphorescence has been proven to be a valuable tool for the measurement of oxygen concentrations both in vitro and in vivo. For biological measurements the relatively long lifetimes of phosphorescence have promoted time-domain-based devices using xenon arc flashlamps as the most common excitation light source. The resulting complex form of the excitation pulse leads to complications in the analysis of phosphorescence lifetimes and ultimately to errors in the recovered pO2 values. Although the problem has been recognized, the consequences on in vivo phosphorescence lifetime measurements have been neglected so far. In this study, the consequences of finite excitation flash duration are analyzed using computer simulations, and a method for the recovery of phosphorescence decay times from complex photometric signals is presented. The analysis provides an explanation as to why different calibration constants are reported in the literature and presents a unified explanation whereby calibration constants are not solely a property of the dye but also of the measuring device. It is concluded that complex excitation pulse patterns without appropriate analysis methods lead to device-specific calibration constants and nonlinearity and can be a potent source of errors when applied in vivo. The method of analysis presented in this article allows reliable phosphorescence lifetime measurements to be made for oxygen pressure measurements and can easily be applied to existing phosphorimeters.

Algorithms↗

Fentanyl-fluanisone-midazolam combination results in more stable hemodynamics than does urethane alpha-chloralose and 2,2,2-tribromoethanol in mice.

Near-physiologic hemodynamic conditions for several hours were needed to study cardiovascular physiology in a murine model. We compared two commonly used anesthetic treatments, urethane alpha-chloralose (U-alphaCh; 968 mg U and 65 mg alphaCh/kg) and 2,2,2-tribromoethanol (TBE; 435 mg/kg) and fentanyl fluanisone midazolam (FFM; 3.313 mg fentanyl, 104.8 mg fluanisone, and 52.42 mg midazolam/kg) with respect to mean arterial blood pressure (MAP) and heart rate (HR) for 100 min at similar levels of surgical anesthesia. Assessed every 10 to 15 min, the U-alphaCh+TBE group maintained a significantly (P < 0.001) lower mean MAP (49 4 mmHg) than did the FFM group (78 5 mmHg). Mean HR in the U-alphaCh+TBE group significantly (P < 0.001) increased from 308 34 bpm at the beginning to 477 43 bpm at the end of the experiment. In comparison, the FFM group showed a stable HR of 431 37 bpm. The MAP and HR of the U-alphaCh+TBE group were extremely unstable, with sudden and unpredictable changes in MAP when examined at 1-min intervals. The results of our study show that U-alphaCh+TBE anesthesia should not be used in murine models in which stable, near-physiologic hemodynamics are needed for cardiovascular studies.

Anesthesia↗