Impact of pelvic nodal irradiation with intensity-modulated radiotherapy on treatment of prostate cancer.

PURPOSE: The aim of this study was to evaluate the feasibility of treating the pelvic lymphatic regions during prostate intensity-modulated radiotherapy (IMRT) with respect to our routine acceptance criteria. METHODS AND MATERIALS: A series of 10 previously treated prostate patients were randomly selected and the pelvic lymphatic regions delineated on the fused magnetic resonance/computed tomography data sets. A targeting progression was formed from the prostate and proximal seminal vesicles only to the inclusion of all pelvic lymphatic regions and presacral region resulting in 5 planning scenarios of increasing geometric difficulty. IMRT plans were generated for each stage for two accelerator manufacturers. Dose volume histogram data were analyzed with respect to dose to the planning target volumes, rectum, bladder, bowel, and normal tissue. Analysis was performed for the number of segments required, monitor units, "hot spots," and treatment time. RESULTS: Both rectal endpoints were met for all targets. Bladder endpoints were not met and the bowel endpoint was met in 40% of cases with the inclusion of the extended and presacral lymphatics. A significant difference was found in the number of segments and monitor units with targeting progression and between accelerators, with the smaller beamlets yielding poorer results. Treatment times between the 2 linacs did not exhibit a clinically significant difference when compared. CONCLUSIONS: Many issues should be considered with pelvic lymphatic irradiation during IMRT delivery for prostate cancer including dose per fraction, normal structure dose/volume limits, planning target volumes generation, localization, treatment time, and increased radiation leakage. We would suggest that, at a minimum, the endpoints used in this work be evaluated before beginning IMRT pelvic nodal irradiation.

Endpoint Determination↗

Ultra-thin TLDs for skin dose determination in high energy photon beams.

Estimation of surface dose is very important for patients undergoing radiation therapy. In this work we investigate the dose at the surface of a water phantom and at a depth of 0.007 cm, the practical reference depth for skin as recommended by ICRP and ICRU, with ultra-thin TLDs and Monte Carlo calculations. The calculations and measurements were carried out for fields ranging from 5 x 5 cm2 to 20 x 20 cm2 for 6 MV, 10 MV and 18 MV photon beams. The variation of the surface dose with angle of incidence and field size was investigated. Also, the exit dose was computed and measured for the same fields and angles of incidence. The dose at the ICRU reference depth was computed. Good agreement (+/-5%) was achieved between measurements and calculations. The surface dose at the entrance increased with the angle of incidence and/or the field size. The exit dose decreased with the angle of incidence but it increased with field size. The dose at the surface of the patient is mostly dependent on the beam energy, modality and beam obliquity rather than the field size and field separation. By correlating TLD measurements with Monte Carlo calculations, we were able to predict the dose at the skin surface with good accuracy. Knowing the dose received at the surface of the patient can lead to prediction of skin reactions helping with the design of new treatment techniques and alternative dose fractionation schemes.

Breast Neoplasms↗

A practical Monte Carlo MU verification tool for IMRT quality assurance.

Quality assurance (QA) for intensity-modulated radiation therapy (IMRT) treatment planning and beam delivery, using ionization chamber measurements and film dosimetry in a phantom, is time consuming. The Monte Carlo method is the most accurate method for radiotherapy dose calculation. However, a major drawback of Monte Carlo dose calculation as currently implemented is its slow speed. The goal of this work is to bring the efficiency of Monte Carlo into a practical range by developing a fast Monte Carlo monitor unit (MU) verification tool for IMRT. A special estimator for dose at a point called the point detector has been used in this research. The point detector uses the next event estimation (NEE) method to calculate the photon energy fluence at a point of interest and then converts it to collision kerma by the mass energy absorption coefficient assuming the presence of transient charged particle equilibrium. The MU verification tool has been validated by comparing the calculation results with measurements. It can be used for both patient dose verification and phantom QA calculation. The dynamic leaf-sequence log file is used to rebuild the actual MLC leaf sequence in order to predict the dose actually received by the patient. Dose calculations for 20 patient plans have been performed using the point detector method. Results were compared with direct Monte Carlo simulations using EGS4/MCSIM, which is a well-benchmarked Monte Carlo code. The results between the point detector and MCSIM agreed to within 2%. A factor of 20 speedup can be achieved with the point detector method compared with direct Monte Carlo simulations.

Body Burden↗

Characterization of megavoltage electron beams delivered through a photon multi-leaf collimator (pMLC).

A study is presented that characterizes megavoltage electron beams delivered through an existing double-focused photon multi-leaf collimator (pMLC) using film measurements in a solid water phantom. Machine output stability and linearity were evaluated as well as the effect of source-to-surface distance (SSD) and field size on the penumbra for electron energies between 6 and 18 MeV over an SSD range of 60-100 cm. Penumbra variations as a function of field size, depth of measurement and the influence of the jaws were also studied. Field abutment, field flatness and target coverage for segmented beams were also addressed. The measured field size for electrons transported through the pMLC was the same as that for an x-ray beam up to SSDs of 70 cm. At larger SSD, the lower energy electron fields deviated from the projected field. Penumbra data indicated that 60 cm SSD was the most favourable treatment distance. Backprojection of P(20-80) penumbra data yielded a virtual source position located at 98.9 cm from the surface for 18 MeV electrons. For 6 MeV electrons, the virtual source position was at a distance of 82.6 cm. Penumbra values were smaller for small beam slits and reached a near-constant value for field widths larger than 5 cm. The influence of the jaws had a small effect on the penumbra. The R90 values ranged from 1.4 to 4.8 cm between 6 and 21 MeV as measured at 60 cm SSD for a 9 x 9 cm2 field. Uniformity and penumbra improvement could be demonstrated using weighted abutted fields especially useful for small segments. No detectable electron leakage through the pMLC was observed. Bremsstrahlung measurements taken at 60 cm SSD for a 9 x 9 cm2 field as shaped by the pMLC compared within 1% to bremsstrahlung measurements taken at 100 cm SSD for a 10 x 10 cm2 electron applicator field at 100 cm SSD.

Electrons↗

Investigation of MR image distortion for radiotherapy treatment planning of prostate cancer.

MR imaging based treatment planning for radiotherapy of prostate cancer is limited due to MR imaging system related geometrical distortions, especially for patients with large body sizes. On our 0.23 T open scanner equipped with the gradient distortion correction (GDC) software, the residual image distortions after the GDC were <5 mm within the central 36 cm x 36 cm area for a standard 48 cm field of view (FOV). In order to use MR imaging alone for treatment planning the effect of residual MR distortions on external patient contour determination, especially for the peripheral regions outside the 36 cm x 36 cm area, must be investigated and corrected. In this work, we performed phantom measurements to quantify MR system related residual geometric distortions after the GDC and the effective FOV. Our results show that for patients with larger lateral dimensions (>36 cm), the differences in patient external contours between distortion-free CT images and GDC-corrected MR images were 1-2 cm because of the combination of greater gradient distortion and loss of field homogeneity away from the isocentre and the uncertainties in patient setup during CT and MRI scans. The measured distortion maps were used to perform point-by-point corrections for patients with large dimensions inside the effective FOV. Using the point-by-point method, the geometrical distortion after the GDC were reduced to <3 mm for external contour determination and the effective FOV was expanded from 36 cm to 42 cm.

Humans↗

Elongated beamlets: a simple technique for segment and MU reduction for sMLC IMRT delivery on accelerators utilizing 5 mm leaf widths.

The focus of this work is to demonstrate the effects of using an elongated beamlet to achieve similar dose conformity as achieved with a square beamlet while reducing the number of segments and subsequent MU required. A series of 10 patients were planned for IMRT delivery to the prostate using minimum beamlet sizes of 5x5 mm2 (default scheme), 10x5 mm2 with the short axis parallel to the prostate-rectum interface (scheme 1), and 10x5 mm2 with the short axis perpendicular to the prostate-rectum interface (scheme 2). All other parameters between plans were left unchanged. Plans were appropriately normalized and evaluated for R65, R40, conformity index, total number of segments and MU. All plans were generated using the Corvus inverse planning system. The average number of segments in this study decreased by approximately 49% for both schemes 1 and 2. The subsequent number of MU required decreased by approximately 34.6%. The resultant modified modulation scaling factor (MSFmod) decreased by approximately 34.3%. Additionally, we found that each isodose distribution using scheme 2 would still meet our clinical acceptance criteria with no visible degradation in the dose distribution as compared with the default scheme. In conclusion, we have demonstrated that it is possible to achieve similar results as those obtained using a 5x5 mm2 beamlet with respect to target coverage and critical structure sparing by using strategically oriented elongated beamlets. This technique directly translates to a decreased MSF(mod) allowing for decreased leakage dose to the patient, a decreased risk of exceeding secondary shielding limits in pre-existing vaults, and shorter treatment times.

Algorithms↗

Coulomb explosion effect and the maximum energy of protons accelerated by high-power lasers.

The acceleration of light ions (protons) through the interaction of a high-power laser pulse with a double-layer target is theoretically studied by means of two-dimensional particle-in-cell simulations and a one-dimensional analytical model. It is shown that the maximum energy acquired by the accelerated light ions (protons) depends on the physical characteristics of a heavy-ion layer (electron-ion mass ratio and effective charge state of the ions). In our theoretical model, the hydrodynamic equations for both electron and heavy-ion species are solved and the test-particle approximation for the light ions (protons) is applied. The heavy-ion motion is found to modify the longitudinal electric field distribution, thus changing the acceleration conditions for the protons.

Biophysics↗

Effect of patient variation on standard- and hypo-fractionated radiotherapy of prostate cancer.

Recent publications suggested that the alpha/beta ratio in the well-known linear quadratic (LQ) model could be as low as 1.5 Gy for prostate cancer, indicating that prostate cancer control might be very sensitive to changes in the dose fractionation scheme. This also suggests that the standard-fractionation scheme based on large alpha/beta ratios may not be optimal for the radio-therapeutic management of prostate cancer. Hypo-fractionated radiotherapy for prostate cancer has received more attention recently as an alternative treatment strategy, which may lead to reduced treatment time and cost. However, hypo-fractionated radiotherapy may be more sensitive to patient variation in terms of disease control than standard-fractionated radiotherapy. The variation of LQ parameters alpha and beta for a patient population may compromise the outcome of the treatment. This effect can be studied by the introduction of the sigmaalpha and sigmabeta parameters, which are the standard deviations of Gaussian distributions around alpha0 and beta0. The purpose of this study is to examine the effect of patient variation in alpha and beta on tumour control probability for standard- and hypo-fractionated radiotherapy of prostate cancer. The tumour control probability based on the LQ model is calculated using parameters alpha, beta, sigmaalpha and sigmabeta. Our results show that sigmaalpha is an important parameter for radiotherapy fractionation, independent of the alpha/beta ratio. A large sigmaalpha will result in a significant increase in the radiation dose required to achieve the same 95% TCP. Compared with the standard-fractionated scheme, sigmaalpha has a smaller effect on hypo-fractionated treatment at lower alpha/beta ratios. On the other hand, for lower alpha/beta ratios, the beta term also plays a more important role in cell-killing and therefore the patient variation parameter sigmabeta must be considered when designing a new dose fractionation scheme.

Cell Survival↗

Dosimetric verification of IMRT treatment planning using Monte Carlo simulations for prostate cancer.

The purpose of this work is to investigate the accuracy of dose calculation of a commercial treatment planning system (Corvus, Normos Corp., Sewickley, PA). In this study, 30 prostate intensity-modulated radiotherapy (IMRT) treatment plans from the commercial treatment planning system were recalculated using the Monte Carlo method. Dose-volume histograms and isodose distributions were compared. Other quantities such as minimum dose to the target (D(min)), the dose received by 98% of the target volume (D98), dose at the isocentre (D(iso)), mean target dose (D(mean)) and the maximum critical structure dose (D(max)) were also evaluated based on our clinical criteria. For coplanar plans, the dose differences between Monte Carlo and the commercial treatment planning system with and without heterogeneity correction were not significant. The differences in the isocentre dose between the commercial treatment planning system and Monte Carlo simulations were less than 3% for all coplanar cases. The differences on D98 were less than 2% on average. The differences in the mean dose to the target between the commercial system and Monte Carlo results were within 3%. The differences in the maximum bladder dose were within 3% for most cases. The maximum dose differences for the rectum were less than 4% for all the cases. For non-coplanar plans, the difference in the minimum target dose between the treatment planning system and Monte Carlo calculations was up to 9% if the heterogeneity correction was not applied in Corvus. This was caused by the excessive attenuation of the non-coplanar beams by the femurs. When the heterogeneity correction was applied in Corvus, the differences were reduced significantly. These results suggest that heterogeneity correction should be used in dose calculation for prostate cancer with non-coplanar beam arrangements.

Computer Simulation↗

Effect of statistical uncertainties on Monte Carlo treatment planning.

This paper reviews the effect of statistical uncertainties on radiotherapy treatment planning using Monte Carlo simulations. We discuss issues related to the statistical analysis of Monte Carlo dose calculations for realistic clinical beams using various variance reduction or time saving techniques. We discuss the effect of statistical uncertainties on dose prescription and monitor unit calculation for conventional treatment and intensity-modulated radiotherapy (IMRT) based on Monte Carlo simulations. We show the effect of statistical uncertainties on beamlet dose calculation and plan optimization for IMRT and other advanced treatment techniques such as modulated electron radiotherapy (MERT). We provide practical guidelines for the clinical implementation of Monte Carlo treatment planning and show realistic examples of Monte Carlo based IMRT and MERT plans.

Computer Simulation↗

A particle track-repeating algorithm for proton beam dose calculation.

A particle track-repeating algorithm has been developed for proton beam dose calculation for radiotherapy. Monoenergetic protons with 250 MeV kinetic energy were simulated in an infinite water phantom using the GEANT3 Monte Carlo code. The changes in location, angle and energy for every transport step and the energy deposition along the track were recorded for the primary protons and all secondary particles. When calculating dose for a patient with a realistic proton beam, the pre-generated particle tracks were repeated in the patient geometry consisting of air, soft tissue and bone. The medium and density for each dose scoring voxel in the patient geometry were derived from patient CT data. The starting point, at which a proton track was repeated, was determined according to the incident proton energy. Thus, any protons with kinetic energy less than 250 MeV can be simulated. Based on the direction of the incident proton, the tracks were first rotated and for the subsequent steps, the scattering angles were simply repeated for air and soft tissue but adjusted properly based on the scattering power for bone. The particle step lengths were adjusted based on the density for air and soft tissue and also on the stopping powers for bone while keeping the energy deposition unchanged in each step. The difference in nuclear interactions and secondary particle generation between water and these materials was ignored. The algorithm has been validated by comparing the dose distributions in uniform water and layered heterogeneous phantoms with those calculated using the GEANT3 code for 120, 150, 180 and 250 MeV proton beams. The differences between them were within 2%. The new algorithm was about 13 times faster than the GEANT3 Monte Carlo code for a uniform phantom geometry and over 700 times faster for a heterogeneous phantom geometry.

Algorithms↗

Dosimetric evaluation of MRI-based treatment planning for prostate cancer.

The purpose of this study is to evaluate the dosimetric accuracy of MRI-based treatment planning for prostate cancer using a commercial radiotherapy treatment planning system. Three-dimensional conformal plans for 15 prostate patients were generated using the AcQPlan system. For each patient, dose distributions were calculated using patient CT data with and without heterogeneity correction, and using patient MRI data without heterogeneity correction. MR images were post-processed using the gradient distortion correction (GDC) software. The distortion corrected MR images were fused to the corresponding CT for each patient for target and structure delineation. The femoral heads were delineated based on CT. Other anatomic structures relevant to the treatment (i.e., prostate, seminal vesicles, lymph notes, rectum and bladder) were delineated based on MRI. The external contours were drawn separately on CT and MRI. The same internal contours were used in the dose calculation using CT- and MRI-based geometries by directly transferring them between MRI and CT as needed. Treatment plans were evaluated based on maximum dose, isodose distributions and dose-volume histograms. The results confirm previous investigations that there is no clinically significant dose difference between CT-based prostate plans with and without heterogeneity correction. The difference in the target dose between CT- and MRI-based plans using homogeneous geometry was within 2.5%. Our results suggest that MRI-based treatment planning is suitable for radiotherapy of prostate cancer.

Humans↗

Lens dose in MLC-based IMRT treatments of the head and neck.

PURPOSE: The objectives of this work are: (1) to determine typical dose to the lens during step-and-shoot intensity modulated radiotherapy (IMRT) treatments of the head and neck, and (2) to report on the dose calculation accuracy of a commercial inverse planning system in predicting lens dose. METHODS AND MATERIALS: The Corvus inverse treatment planning system (Nomos, Cranberry Township, PA) was used to plan IMRT treatments for patients with head-and-neck cancers in our clinic. Patients were treated on Varian C-series linacs (Varian, Palo Alto, CA) with 4-MV or 6-MV X-rays. A Rando phantom (Alderson Laboratories, Stamford, CT) was specially modified to accommodate 1 x 1 x 1 mm(3) thermoluminescent dosimeters at the position of the lens. The IMRT treatment plans were then delivered to the modified Rando phantom. The thermoluminescent dosimeter measurements were converted to dose and taken as an estimate of the lens dose. A total of 20 cases were used in this study (15 cases with 4 MV and 5 cases with 6 MV). RESULTS: Expressed as a percentage of the prescription dose, the mean dose to the left and right lens for all 4-MV cases was 9.1% (range, 2.0% to 61.3%). For the 6-MV cases, the mean dose to the left and right lens was 12.8% (range, 3.6% to 41.3%). For both the 4-MV and 6-MV cases, the case of maximum dose occurred when the IMRT treatment target included volumes superior to the level of the lens. The field size and number of monitor units did not correlate with the measured lens dose. The only factor of significance affecting lens dose was the inferior-to-superior distance of the target to the lens. For target-lens distance >/=6 mm, the maximum measured lens doses were 5.9% and 9.0% relative to the prescribed dose for the 4-MV and 6-MV beams, respectively. These data are similar to those observed in conventional head-and-neck treatments. For all cases, the difference between the dose measured and that predicted by Corvus was less than 2% and 4% of the dose prescribed to the gross tumor volume for the 4-MV and 6-MV cases, respectively. CONCLUSION: In IMRT, factors such as leaf leakage and number of monitor units play a secondary role and are not more significant than what is observed in conventional head-and-neck treatment when the lens is shielded by the collimator jaws. The target-lens distance is the parameter that affects the lens dose most strongly. For cases where the tumor is at or above the level of the lens, the lens dose can amount to an appreciable fraction of the prescription dose. To keep the lens dose to a minimum, noncoplanar beams that enter or exit into the lens should not be used.

Calibration↗

Shielding evaluation for IMRT implementation in an existing accelerator vault.

A formalism is developed for evaluating the shielding in an existing vault to be used for IMRT. Existing exposure rate measurements are utilized as well as a newly developed effective modulation scaling factor. Examples are given for vaults housing 6, 10 and 18 MV linear accelerators. The use of an 18 MV Siemens linear accelerator is evaluated for IMRT delivery with respect to neutron production and the effects on individual patients. A modified modulation scaling factor is developed and the risk of the incurrence of fatal secondary malignancies is estimated. The difference in neutron production between 18 MV Varian and Siemens accelerators is estimated using Monte Carlo results. The neutron production from the Siemens accelerator is found to be approximately 4 times less than that of the Varian accelerator resulting in a risk of fatal secondary malignancy occurrence of approximately 1.6% when using the SMLC delivery technique and our measured modulation scaling factors. This compares with a previously published value of 1.6% for routine 3D CRT delivery on the Varian accelerator.

Air Pollutants, Radioactive↗