Search PubMed⌕ Search

Biomedical subjects

C-H Luo

Publications and source records attributed to C-H Luo.

3 recordsLinked to original sources

Morse code recognition system with fuzzy algorithm for disabled persons.

It is generally known that Morse code is an efficient input method for one or two switches and it is made from long and short sounds separated by silence between the sounds. The long-to-short ratio in the definition is always 3 to 1, but the long-to-short ratio variation for a disabled person is so large that it is difficult to recognize. In the last few years, several Morse code recognition methods have been successfully built on the LMS adaptive algorithms and neural network algorithm. But LMS-related adaptive algorithms need mass computation to infer the characteristic of the controller; also the neural network must learn first, by inputting some data before it is used to recognize the Morse code sequence. In this study, two fuzzy algorithms are used to recognize the unstable Morse code sequences and the result demonstrates a significant improvement of recognition for real time signal processing in a single-chip microprocessor.

Adolescent↗

An experimental design for quantification of cardiovascular responses to music stimuli in humans.

There have been several researches on the relationship between music and human physiological or psychological responses. However, there are cardiovascular index factors that have not been explored quantitatively due to the qualitative nature of acoustic stimuli. This study proposes and demonstrates an experimental design for quantification of cardiovascular responses to music stimuli in humans. The system comprises two components: a unit for generating and monitoring quantitative acoustic stimuli and a portable autonomic nervous system (ANS) analysis unit for quantitative recording and analysis of the cardiovascular responses. The experimental results indicate that the proposed system can exactly achieve the goal of full control and measurement for the music stimuli, and also effectively support many quantitative indices of cardiovascular response in humans. In addition, the analysis results are discussed and predicted in the future clinical research.

Acoustic Stimulation↗

Micromachined oxygen gas sensors for microscopic energy consumption measurement systems.

Although the indirect calorimeter is a useful tool, its size and expense mean that it is seldom used in hospitals. Furthermore, its flow-through measurement technique dilutes respiratory variations, so they can only be detected with some form of high-precision instrumentation. This study employs MEMS techniques to develop an oxygen sensor as one part of a microscopic energy consumption measurement system, which measures respiration dynamics in a real time manner. The oxygen sensor comprises a polysilicon resistor and a Li-doped (2 wt%) tin-oxide sensing film attached to a thermally isolated silicon-nitride membrane. The power consumption of the sensor is less than 25 mW at an operating temperature of 150 degrees C. Furthermore, it measures oxygen concentrations between 25 and 85% with a linear output response. These characteristics render the proposed sensor suitable for use within a microscopic energy consumption measurement system in either hospital or homecare environments.

Animals↗