Search PubMed⌕ Search

Biomedical subjects

C von Birgelen

Publications and source records attributed to C von Birgelen.

At least 19 recordsLinked to original sources

Resistant hypertension in patients with chronic aortic dissection.

Strict blood pressure control is pivotal in the management of patients with aortic dissection (AD), but is frequently difficult to achieve. We determined antihypertensive medical therapy and levels of blood pressure (BP) control in 40 patients with chronic AD. Patient charts were reviewed for clinical variables, serial BP measurements, and antihypertensive drug therapy. Patients were divided into two groups: patients in group 1 had effective BP control (<135/80 mmHg), patients in group 2 had resistant hypertension (BP>/=135/80 mmHg despite prescription of at least three antihypertensive drugs). Overall, systolic BP (SBP) was 130+/-20 mmHg, and diastolic BP (DBP) was 72+/-13 mmHg. Patients received a median of 4 (1-6) antihypertensive drugs. beta-blockers were used in 38/40 (95%) patients. Effective BP control was achieved in 24/40 (60%) patients (group 1), while 16/40 (40%) patients had resistant hypertension (group 2) despite receiving significantly more antihypertensive drugs (5 [4-6] vs 4 [1-5], P=0.001). Mean SBP was 116+/-9 (101-132) mmHg in group 1 and 151+/-13 (137-181) mmHg in group 2 (P<0.001); there was no difference in DBP. Group 2 patients had a significantly higher body mass index and were younger than patients in group 1. In conclusion, in the majority of patients with chronic AD, effective BP control can be achieved, but usually requires the combination of multiple antihypertensive drugs. However, in a significant proportion of patients (40%), who appear to be younger and more obese, medical therapy fails to achieve effective BP control despite use of a multiple drug regimen.

Adrenergic alpha-Antagonists↗

Acute and long-term outcome after coronary artery perforation during percutaneous coronary interventions.

BACKGROUND: Coronary artery perforation is a rare but serious complication of percutaneous coronary interventions (PCI). METHODS: We reviewed our database for cases of overt coronary perforation during PCI procedures. Hospital charts, procedural reports, and coronary angiograms of these patients were reviewed, with particular emphasis on mechanisms of perforation, management of the complication, and clinical outcome. RESULTS: Between 01/1998 and 12/2003, a total of 19 cases (mean age: 66+/-8 years, 13 male) of coronary perforation occurred during 6433 PCI procedures performed within this period (incidence: 0.3%). In 12/19 (63%) cases, perforation occurred during recanalisation procedures of chronic total occlusions of coronary arteries. In all but one patient, non-surgical management was attempted: 2 out of 19 (11%) patients were treated conservatively by reversal of heparin anticoagulation. Prolonged balloon inflation at the perforation site was applied in 10/19 (53%) patients. Six (32%) patients received stents (5 of them received covered stentgrafts), 3 (16%) patients developed cardiac tamponade requiring percardiocentesis, and only 2 (11%) patients underwent bailout surgical repair. There were 2 (11%) deaths early after the procedure. CONCLUSION: Coronary perforation during PCI is a rare complication, but is associated with significant morbidity and mortality. In the majority of patients, non-surgical management is both feasible and associated with a high success-rate.

Aged↗

Insulin sensitivity and coronary vasoreactivity: insulin sensitivity relates to adenosine-stimulated coronary flow response in human subjects.

OBJECTIVE: Diabetes is associated with coronary microvasculature abnormalities and impaired coronary flow reserve (CFR). CFR is the ratio of coronary flow under maximal vasodilation to basal flow and is a measure for coronary vasoreactivity. Insulin resistance is the central defect in the development of type 2 diabetes, preceding its onset by 10-20 years. Thus, the relationship between insulin sensitivity and CFR in nondiabetic subjects is particularly interesting. The aim of the study was to investigate this relationship. DESIGN: Cross-sectional study. PATIENTS: The study population consisted of 18 nondiabetic subjects without coronary artery stenosis on coronary angiography. We excluded patients with structural heart disease or with conditions affecting CFR or insulin sensitivity such as low density lipoprotein (LDL)-cholesterol > or = 4.14 mmol/l, smoking, hypertension or obesity with a body mass index (BMI) > 28 kg/m(2). MEASUREMENTS AND RESULTS: CFR was 3.1 +/- 0.8 (range 1.7-4.8), as assessed by intracoronary Doppler measurements in the left anterior descending coronary arteries after adenosine stimulation. Intravascular ultrasound revealed zero to moderate coronary atherosclerotic changes. Whole-body insulin sensitivity (M-value) was 7.5 +/- 2.9 mg/kg/min (range 2.2-12.6), as assessed by the hyperinsulinaemic-euglycaemic clamp test. Subjects with low CFR (< 3.0) had a significantly lower M-value than subjects with normal CFR (> 3.0) (6.0 +/- 2.5 vs. 9.0 +/- 2.5 mg/kg/min, P = 0.021). Univariate linear regression demonstrated a strong correlation between CFR and M-value (r = 0.76, P < 0.001). In multiple regression analysis, the significant association of CFR with M-value was independent of potential confounders (sex, age, BMI, LDL-cholesterol and plaque burden on intravascular ultrasound). Bootstrap analysis corroborated this finding. CONCLUSIONS: Whole-body insulin sensitivity relates to coronary vasoreactivity. Across a wide range of both insulin sensitivity and coronary flow reserve from markedly abnormal to normal values, an increase in insulin sensitivity appears to be associated with an increase in coronary flow reserve. Insulin resistance is therefore associated with coronary microvasculature abnormalities in nondiabetics.

Adenosine↗

Intravascular ultrasound assessment of coronary atherosclerosis and percutaneous interventions.

Intravascular ultrasound (IVUS) is a catheter-based technique which provides high-resolution cross-sectional images of both, coronary lumen and vessel wall. Various scientific studies recently established IVUS as a valuable tool for the assessment of the natural history of coronary atherosclerosis and the effect of different pharmacological and non-pharmacological interventions on progression-regression of atherosclerosis. Novel technical approaches that use IVUS radiofrequency data may provide further interesting information on vessel wall characteristics but require further validation. In addition, numerous trials applied IVUS to assess the short- and long-term outcome of different percutaneous coronary interventions, including the implantation of drug-eluting stents. Besides the importance of IVUS in the field of scientific trials, IVUS can be clinically helpful for the evaluation of angiographically ambiguous lesions, guidance of catheter-based interventions, and management of complications. Settings in which IVUS may be particular useful are: ostial and bifurcation lesions; the presence of diffuse atherosclerotic disease; severely calcified or very tight lesions; relatively small vessels; diabetic patients; and if multiple, long or novel stents are implanted. This article gives an overview on the value of IVUS for the assessment of coronary atherosclerosis and percutaneous coronary interventions. In this context, we reviewed a selection of recently published IVUS studies which provide interesting new information in this field.

Angioplasty, Balloon, Coronary↗

Continued improvement of clinical outcome and cost effectiveness following intravascular ultrasound guided PCI: insights from a prospective, randomised study.

OBJECTIVE: To investigate in a prospective randomised study both long term clinical effects and cost effectiveness of percutaneous coronary interventions (PCI) with or without intravascular ultrasound (IVUS) guidance. METHODS: 108 male patients with stable angina referred for PCI of a significant coronary lesion were randomly assigned to IVUS guided PCI or conventional PCI. Individual accumulated costs of the entire follow up period were calculated and compared in the randomisation groups. Effectiveness of treatment was measured by freedom from major adverse cardiac events. RESULTS: Cost effectiveness of IVUS guided PCI that was noted at six months was maintained and even accentuated at long term follow up (median 2.5 years). The cumulated cost level was found to be lower for the IVUS guided group, with a cumulated cost of &163 672 in the IVUS guided group versus &313 706 in the coronary angiography group (p = 0.01). Throughout the study, mean cost per day was lower in the IVUS guided PCI group (&2.7 v & 5.2; p = 0.01). In the IVUS group, 78% were free from major adverse cardiac events versus 59% in the coronary angiography group (p = 0.04) with an odds ratio of 2.5 in favour of IVUS guidance. CONCLUSION: IVUS guidance results in continued improvement of long term clinical outcome and cost effectiveness. The results of this study suggest that IVUS guidance may be used more liberally in PCI.

Adult↗

Plaque distribution and vascular remodeling of ruptured and nonruptured coronary plaques in the same vessel: an intravascular ultrasound study in vivo.

OBJECTIVES: This study was designed to identify potential differences between the intravascular ultrasound (IVUS) characteristics of spontaneously ruptured and nonruptured coronary plaques. BACKGROUND: The identification of vulnerable plaques in vivo may allow targeted prevention of acute coronary events and more effective evaluation of novel therapeutic approaches. METHODS: Intravascular ultrasound was used to identify 29 ruptured plaques in arteries containing another nonruptured plaque in an adjacent segment. Intravascular ultrasound characteristics of these plaques were compared with plaques of computer-matched controls without evidence of plaque rupture. Plaque distribution was assessed by measuring the eccentricity of lumen location (inside the total vessel). Lumen cross-sectional area narrowing was calculated as [1 - (target/reference lumen area)] x 100%. A remodeling index was calculated as lesion/reference arterial area (>1.05 = compensatory enlargement, <0.95 = shrinkage). RESULTS: Among the three groups of plaques, there was no significant difference in quantitative angiographic parameters, IVUS reference dimensions and IVUS lumen cross-sectional area narrowing. There was a difference in plaque distribution; lumen location by IVUS was significantly more eccentric in ruptured than in nonruptured (p = 0.002) and control plaques (p < 0.0001). The arc of disease-free vessel wall was larger in ruptured than in control plaques (p < 0.0001). The remodeling pattern of ruptured and nonruptured plaques differed significantly from that of the control plaques (p = 0.0001 and 0.003); compensatory enlargement was found in 66%, 48%, and 17%, whereas shrinkage was found in 7%, 10% and 48%, respectively. CONCLUSIONS: Intravascular ultrasound assessment of plaque distribution and vascular remodeling may help to classify plaques with the highest probability of spontaneous rupture.

Coronary Artery Disease↗

Abnormal coronary flow velocity reserve after coronary intervention is associated with cardiac marker elevation.

BACKGROUND: Residual reduction of relative coronary flow velocity reserve (rCVR) after successful coronary intervention has been related to microvascular impairment. However, the incidence of cardiac enzyme elevation as a surrogate marker of an underlying embolic myocardial injury in these cases has not been studied. METHODS AND RESULTS: A series of 55 consecutive patients with successful coronary stenting, periprocedural intracoronary Doppler analysis, and determination of creatine kinase (CK; upper limit of normal [ULN] for women 70 IU/L, for men 80 IU/L) and cardiac troponin T (cTnT; bedside test, threshold 0.1 ng/mL) before and 6, 12, and 24 hours after intervention were studied. Postprocedural rCVR was the only intracoronary Doppler parameter that independently correlated with cTnT (r=-0.498, P<0.001) and CK outcome (r=-0.406, P=0.002). Receiver operating characteristic analysis identified a postprocedural rCVR of 0.78 as the best discriminating value, with a sensitivity of 83.3% and 69.2% and a specificity of 79.1% and 76.2% for detection of cTnT and CK elevation, respectively. Stratified according to this cutoff value, the incidence of cTnT elevation was 52.6% in patients with (n=19) and 5.6% in patients without (n=36) a postprocedural rCVR <0.78 (P<0.001), associated with a CK elevation >1 times the ULN in 36.8% and 5.6% (P=0.005) of patients, respectively. CONCLUSIONS: Cardiac marker elevation can frequently be found after coronary procedures that are associated with a persistent reduction of rCVR, indicating procedural embolization of atherothrombotic debris with microvascular impairment and myocardial injury as a potential underlying mechanism.

Aged↗

Early clinical experience with the 6 French Angio-Seal device: immediate closure of femoral puncture sites after diagnostic and interventional coronary procedures.

The objective of this study was to assess the early safety and efficacy of the novel 6 Fr Angio-Seal device for routine clinical use after diagnostic cardiac catheterization and coronary angioplasty. In a prospective study, we used the 6 Fr Angio-Seal device in 180 consecutive patients (131 male, 49 female, mean age 60.7 years) for closure of femoral arterial puncture sites immediately after diagnostic (n = 108) or interventional (n = 72) coronary procedures independent of the coagulation status. All patients were monitored for 24 hr after the procedure and followed for 30 days. The closure device was successfully deployed in 95.4% after diagnostic catheterization versus 98.6% after coronary angioplasty (P = 0.963). Immediate hemostasis was achieved in 91.5% versus 90.1% of the patients (P = 0.993). Major complications were observed 1.9% versus 2.8% of the patients (P = 0.885). During 30-day follow-up, no late events or complications were reported. The 6 Fr Angio-Seal device is a safe and effective device that allows for immediate closure of femoral puncture sites after both diagnostic and interventional procedures with a low rate of major complications.

Adult↗

True 3-dimensional reconstruction of coronary arteries in patients by fusion of angiography and IVUS (ANGUS) and its quantitative validation.

BACKGROUND: True 3D reconstruction of coronary arteries in patients based on intravascular ultrasound (IVUS) may be achieved by fusing angiographic and IVUS information (ANGUS). The clinical applicability of ANGUS was tested, and its accuracy was evaluated quantitatively. METHODS AND REUSLTS: In 16 patients who were investigated 6 months after stent implantation, a sheath-based catheter was used to acquire IVUS images during an R-wave-triggered, motorized stepped pullback. First, a single set of end-diastolic biplane angiographic images documented the 3D location of the catheter at the beginning of pullback. From this set, the 3D pullback trajectory was predicted. Second, contours of the lumen or stent obtained from IVUS were fused with the 3D trajectory. Third, the angular rotation of the reconstruction was optimized by quantitative matching of the silhouettes of the 3D reconstruction with the actual biplane images. Reconstructions were obtained in 12 patients. The number of pullback steps, which determines the pullback length, closely agreed with the reconstructed path length (r=0.99). Geometric measurements in silhouette images of the 3D reconstructions showed high correlation (0.84 to 0.97) with corresponding measurements in the actual biplane angiographic images. CONCLUSIONS: With ANGUS, 3D reconstructions of coronary arteries can be successfully and accurately obtained in the majority of patients.

Coronary Angiography↗

Nonsurgical retrieval of embolized coronary stents.

Embolization of coronary stents before deployment is a rare but challenging complication of coronary stenting. Different methods for nonsurgical stent retrieval have been suggested. There were 20 cases (0.90%) of intracoronary stent embolization among 2,211 patients who underwent implantation of 4,066 stents. Twelve of 1,147 manually crimped stents (1.04%) and eight of 2,919 premounted stents were lost (0.27%, P < 0.01) during retraction of the delivery system, because the target lesion could not be either reached or crossed. Percutaneous retrieval was successfully carried out in 10 of 14 patients (71%) in whom retrieval was attempted. In 10 patients, stent retrieval was tried with 1.5-mm low-profile angioplasty balloon catheters (success in 7/10) and in seven cases with myocardial biopsy forceps or a gooseneck snare (success in 3/7). Three patients (15%) underwent urgent coronary artery bypass surgery after failed percutaneous retrieval, but their outcomes were fatal. In two patients, stents were compressed against the vessel wall by another stent, without compromising coronary blood flow. In two patients, a stent was lost to the periphery without clinical side effects; treatment was conservative in these cases. Embolization of stents before deployment is a rare but serious complication of coronary stenting, with hazardous potential for the patient. Manual mounting of stents is associated with a significantly higher risk of stent embolization. Stent retrieval from the coronary circulation with low-profile angioplasty balloon catheters is a readily available and technically familiar approach that has a relatively high success rate.

Aged↗

[Contrast medium echocardiography-assisted pericardial drainage].

The most effective treatment for pericardial effusion and cardiac tamponade is removal of the pericardial fluid. Surgical pericardiotomy is associated with high mortality and morbidity. Similarly, subcostal percutaneous blind pericardiocentesis was reported to have unacceptably high mortality and complication rates. Major complications associated with blind needle punctures are right heart penetration, hemopericardium, puncture of the coronary arteries, liver and lung bleeding. Even under fluoroscopic guidance and electrocardiographic needle monitoring high complication rates persist. Pericardial drainage has been often inadequate, with frequent recurrences of significant pericardial effusions. Two-dimensional echocardiographically guided pericardiocentesis is reported to improve efficacy and safety of percutaneous puncture. Moreover, it allows immediate verification of the procedural success. We evaluated the efficacy and safety of an echocardiographically guided contrast agent controlled pericardiocentesis. This is a retrospective, descriptive study on 126 consecutive patients who underwent percutaneous pericardiocentesis at the University Hospital Essen, Germany, from 1995 to June 2000. There were 51 women (41%) and 75 men (55%) with a mean age of 52 +/- 14 years. Standard techniques for quantification of pericardial effusion were used. Depending on the localization of the pericardial effusion an apical or subxiphoidal approach was chosen. The puncture was performed under echocardiographic guidance and the position of the needle was controlled by injection of contrast agent. Over a long guidewire a pigtail catheter was inserted through a sheath for further drainage of pericardial fluid. The catheter was removed after a maximum of 48 hours to avoid infection of the pericardial cavity. An apical approach was chosen in 98 patients (78%), a subcostal in 28 patients (22%). The procedure was successful in 99% of the attempts. No death or clinical complication occurred. The maximal pericardial diameter measured by two-dimensional echocardiography was 32 +/- 16 mm before and 5.3 +/- 2 mm after drainage. The calculated pericardial effusion was 657 +/- 342 ml. A fluid volume of 605 +/- 342 ml could be drained. In all patients a pericardial catheter was placed for 1.4 +/- 0.8 days. Recurrence of pericardial effusion occurred in 18 patients (14%). Of these, 15 patients underwent repeated successful pericardiocentesis (2.5 +/- 0.8), and 3 patients were referred to surgical pericardiotomy. Pericardiocentesis under echocardiographic contrast agent guidance is a safe, successful and cost effective procedure for diagnostic and therapeutic drainage of pericardial effusion. Two-dimensional echocardiography allows localization of the optimal puncture site as well as the quantification of the effusion depth. The injection of contrast agents into the pericardial cavity improves the safety and accuracy of the procedure. Even recurrent pericardial effusions can be treated successfully.

Adult↗

[Transluminal exclusion of a subclavian artery aneurysm with stent-graft implantation].

In a 73 year-old male patient with generalized atherosclerosis, known infrarenal abdominal aortic aneurysm, renal artery stenosis, and coronary artery disease, an aneurysm of the proximal left subclavian artery was successfully excluded by implantation of a JOSTENT-Peripheral stent graft. Angiographic follow up after 6 and 12 months showed an excellent outcome with complete exclusion of the aneurysm. Intravascular ultrasound showed no neo-intimal hyperplasia within the stent. A computed tomography revealed complete thrombosis of the aneurysm.

Aged↗

On the IVUS plaque volume error in coronary arteries when neglecting curvature.

Plaque volume determined by common linear 3-D IVUS analysis systems will show under- or overestimation in curved vessel segments because these systems approximate the true 3-D transducer pull-back trajectory by a straight line. We developed a mathematical model that showed that the error is primarily dependent on the curvature of the pull-back trajectory and not on vessel tortuosity. Furthermore, we measured this error in vivo in the coronary arteries of 15 patients, comparing the plaque volume using a true 3-D reconstruction method with that of the linear approach. The in vivo plaque volume error ranged from 2.3% to -1.2% for 15 coronary segments with lengths ranging from 38.8 to 89.1 mm (62.2 +/- 13 mm). The volume error introduced by linear 3-D IVUS analysis systems is dependent on the curvature of the pull-back trajectory. The error measured in vivo was small and inversely related to segment length.

Arteries↗

Corrected coronary flow velocity reserve: a new concept for assessing coronary perfusion.

OBJECTIVES: In order to limit the variability of coronary flow velocity reserve (CFVR), we analyzed which factors independently affect CFVR and established a new parameter integrating these factors. BACKGROUND: Coronary flow velocity reserve (CFVR) is a frequently used parameter for evaluating the physiological significance of epicardial stenosis and microvascular function. Since CFVR measurements are done in substantially different hemodynamic and clinical situations, interpretation of CFVR requires correction for major influencing factors. METHODS: In 141 patients with angina-like symptoms and angiographically unobstructed coronary arteries, intracoronary Doppler measurements were performed in at least two coronary vessels. Coronary flow velocity reserve was calculated as the ratio of hyperemic average peak velocity (hAPV), after intracoronary bolus of adenosine, to baseline average peak velocity (bAPV). RESULTS: Analysis of covariance revealed that only bAPV (p < 0.0001) and age (p < 0.0001) were independent factors influencing CFVR. Based on a regression model for estimation of predicted CFVR values, individual CFVR values (CFVRind) obtained at different bAPV and age were transformed in corrected CFVR values (CFVRcorr) by relating them to a mean bAPV of 15 cm/s and a mean age of 55 years. The transformation from CFVRind into CFVRcorr for the left anterior descending artery can be done by using the following equation: CFVRcorr = 2.85*CFVR(ind)*10(0.48*log(bAPV)+(0.0025*age)-1.16). When applying this new parameter to conditions assumed to cause microvascular dysfunction, analysis showed that only patients with diabetes showed a significant decrease of traditional CFVR and CFVRcorr, whereas a history of hypertension and current smoking habit had no influence on CFVRcorr. CONCLUSIONS: The concept of CFVRcorr standardizes CFVR for bAPV and age as the major physiological determinants. Especially in patients with microvascular dysfunction, this approach may help to discriminate between conditions directly affecting vasodilator reserve and conditions primarily affecting bAPV.

Blood Flow Velocity↗

Campylobacter jejuni-induced severe colitis--a rare cause of toxic megacolon.

The development of toxic megacolon as a sequel of infectious colitis is rare. We have observed the very rare case of a campylobacter jejuni-induced toxic megacolon. A 28-year-old man was admitted with severe enterocolitis and appearance of blood in stools. He had been treated with loperamide without success. Two days after admission stool cultures revealed campylobacter jejuni and then an oral antibiotic therapy was started. On the fifth day clinical performance deteriorated again with development of toxic megacolon and consecutive subtotal colectomy. Rectoscopy before discharge after 13 days showed a normal mucosa. The unusual course with first improvement and then rapid deterioration despite adequate therapy was observed in 4 other cases, which may also be a hint of ensuing megacolon. Even in usually harmless enterocolitis like campylobacter infection, predisposing factors such as loperamide are known to precipitate toxic megacolon and should be considered in clinical practice.

Adult↗

Preintervention lesion remodelling affects operative mechanisms of balloon optimised directional coronary atherectomy procedures: a volumetric study with three dimensional intravascular ultrasound.

AIMS: To classify atherosclerotic coronary lesions on the basis of adequate or inadequate compensatory vascular enlargement, and to examine changes in lumen, plaque, and vessel volumes during balloon optimised directional coronary atherectomy procedures in relation to the state of adaptive remodelling before the intervention. DESIGN: 29 lesion segments in 29 patients were examined with intravascular ultrasound before and after successful balloon optimised directional coronary atherectomy procedures, and a validated volumetric intravascular ultrasound analysis was performed off-line to assess the atherosclerotic lesion remodelling and changes in plaque and vessel volumes that occurred during the intervention. Based on the intravascular ultrasound data, lesions were classified according to whether there was inadequate (group I) or adequate (group II) compensatory enlargement. RESULTS: There was no significant difference in patient and lesion characteristics between groups I and II (n = 10 and 19), including lesion length and details of the intervention. Quantitative coronary angiographic data were similar for both groups. However, plaque and vessel volumes were significantly smaller in group I than in II. In group I, 9 (4)% (mean (SD)) of the plaque volume was ablated, while in group II 16 (11)% was ablated (p = 0.01). This difference was reflected in a lower lumen volume gain in group I than in group II (46 (18) mm(3) v 80 (49) mm(3) (p < 0.02)). CONCLUSIONS: Preintervention lesion remodelling has an impact on the operative mechanisms of balloon optimised directional coronary atherectomy procedures. Plaque ablation was found to be particularly low in lesions with inadequate compensatory vascular enlargement.

Adult↗

Size of emptied plaque cavity following spontaneous rupture is related to coronary dimensions, not to the degree of lumen narrowing. A study with intravascular ultrasound in vivo.

OBJECTIVE: To identify any potential relations between the size of an emptied plaque cavity and the remodelling pattern, plaque or vessel dimensions, lumen narrowing, and other ultrasonic lesion characteristics. DESIGN: Intravascular ultrasound was used to examine prospectively 51 ruptured ulcerated coronary plaques. Cross sectional area measurements comprised lumen, vessel, plaque, and emptied plaque cavity. Lumen narrowing was calculated as 1 - (lesion lumen area/reference lumen area) x 100%. A remodelling index was calculated as lesion vessel area/reference vessel area, and plaques were divided into those with values > 1.05 (group A) and </= 1.05 (group B). RESULTS: Of the total of 51 plaques, 36 (71%) were assigned to group A and 15 (29%) to group B. In neither group was there a significant difference in reference dimensions and lumen narrowing. However, lesion vessel (mean (SD): 22.6 (8.1) mm(2) v 17. 5 (4.3) mm(2); p = 0.006) and plaque areas (15.8 (6.2) mm(2) v 12.8 (3.2) mm(2); p = 0.03) were greater in group A than in group B. The cavity inside the plaque was larger in group A than in group B (2.8 (1.6) mm(2) v 1.8 (0.9) mm(2); p = 0.007) and showed a positive linear relation with lesion and reference vessel size (r = 0.58 and 0.56, respectively; p < 0.001), but not with lumen narrowing. CONCLUSIONS: The size of the emptied cavity inside ruptured plaques is on average larger in lesions with adaptive vascular remodelling, and shows a linear relation with lesion plaque and vessel size and with the reference dimensions, but not with the degree of lumen narrowing.

Adult↗